HomeMy WebLinkAboutBLD03-248Waterman & Katz Building
781 Quincy St, Suice 30]
Port Townsend, WA 98368
Phone (360) 379-3208 Pax: (360) 385-7675
a
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO3-24g Issued: 10/15/03 Parcel Number: 989 704 201
Job Address: 702 Water Street Zoning: C_III Occupancy: No Chance
Type: No Chance Total Occupant Load: No Chance
Nature of Work: Repair and replace torcbdown roof, add insulation as needed (see below}.
Owner: Donald Hoskins Contractor: Hope RooSnc - HOPER*043N7
NOTE: all roofing materials to be installed per manufacturer's specifications and UBC Chapter 15
GENERAL CONDITIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
APPR nVFi}/>7 A TF.
. PEDESTRLAN PROTECTION
Provide protection per UBC as needed during construction. See
attached handout including Table 33-A for type of protection
needed based on construction height and pedestrian distance
from construction.
SEDIMENT CONTROL
Rights of way shall be kept free of dirt and debris and swept as
needed during construction,
DEMOLITION
All construction debris to be deposited in Jefferson County
Landfill or other location in accordance with all local, state and
federal laws.
INSULATION
I£ the roof sheeting is being replaced, the roof membrane is
removed, exterior insulation is removed, or no insulation exists,
the roof over a heated space must be insulated to the following
values:
Electric Heat: R-38 for roofs over attic, R-30 for other roofs
Other Fuels: R-30 for roofs over attic, R-21 for other roofs
~ Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Permit #BLTHI;P~.248
C
REOIIIRF,1) iNSPF.f'TiONC
A DDD l1c7L~Tm ~ Tr
•
-------- -
SHEATHING/NAILING (if applicable) a~+aa~v~aLllrll[i1L`
7/16" OSB requires 8d @ 6" o.c. edges & 12" field or 1'/."
staples @ 6" o.c. edges and field.
ROOF VENTING
1 sq. ft. for 150 sq. ft., or 1 sq. ft. for 300 sq. ft. if 50% of vents
aze located at least 3 ft. above eave or cornice or a permanent
vapor bazrier is installed on warm side of attic insulation.
ROOF DRAINAGE
Roof drains shall be sized and dischazged in accordance with the
Uniform Plumbing Code. See attached pages from Appendix M
of the WA State Amendments of the UPC.
FINAL
Building Numbers - 5" numbers of contrasting color posted neaz
main entrance of building and visible from street
Final -Building
GENERAL CONDTTIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's re 'strati
number and a City business license. Failure to provide proof of this documentation prior to work m
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall beinstalled on-site and inspected prior
to beginning construction; ca11385-2294. Adjacentrights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. If your project included he Building Department is unable to pass final inspection on your project until
Public Works requirements have been completed and inspected. For Public Works inspection call 385-
2294.
Call 48 hours before you dig for utility line locates •
I-800-424-5555
Page 2 of 3
~ Permit #BLD03-248
. 7. Finai Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLAN5.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3