Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD03-244
Waterman and Katz Building ~ ~ l61 Quincy Sveeti Suite 301 Port Townsend, W A 98368 Phone: (360) 379-3208 Fax (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-244 Issued: 12/08/03 Parcel Number: 947100 601 Job Address: 504 Foster Street Zoning: RR=II Type: V_N Occupancy: RR=3 Total Occupant Load: 5 Nature of Work: Construct Single-family Dwelling Owner: Ashley Bullitt Contractor: Discovery Bay Construction - DISCOBC090B9 GENERAL CONDITIONS APPLY: See last cage • SEPARATE PERMITS REOUTRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 RE UIRED INSPECTIONS APPRO VED/DATE • TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks ~ ~ Footings \ ~ Forms Reinforcement Interior Footings Porch footings r- UFER "w ~ , FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts & Washers Post to Foundation Wall Positive Connection Holddowns -per engineer design Vents - I2 Required Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page I of 4 Building Permit #BLD03-244 "" REQUIRED iNCPF.C''Ti()NC AADDnA7Dnm ~ mr, FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time Girders Joists Blocking Post to Foundation Wall Connection Positive Connections Treated Wood to Concrete Anchor Bolts & Washers Holddowns -per engineer design PLUMBING Rough-In (D-V-T & Clean outs) Gas supply Water Supply Water Hammer Arrestors Hose Bibbs - backflow protection required Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground MECHANICAL Source Specific Exhaust Fans @ bathrooms (SOcfin), laundry room, (50 cfm) and kitchen (100 cfm) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whole house fan -Guest floor bath • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Building Perini[ #BLD03-244 REQUIRED INSPECTIONS APPR(IVF;II/iIATF ~J FRAMING - - -- - ---- Floor -Engineered BCI plan to be on site at inspection Walls Holddowns -per engineer design Shear walls -per engineer design Shear Panel Blocking Roof -Engineered truss plan to be on-site at time of inspection Attic venting -gable & eave Posts, beams and headers -per engineer design Windows -escape Windows -safety glazing Window U-factor - 0.40 or better Door U-factor - 0.20 or better Skylight U-factor - 0.58 or better NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake - wallw ports Fireblocking Weather Resistive Bamer INSULATION Floor (R-30 ) Walls (R-21) Ceiling (R-38, attic; R-30, vault) Baffles Vapor Barrier -paint DRYWALL NAILING Walls Ceiling Concealed space under stairs FINAL Public Works Sign-off House Numbers - 5" numbers Plumbing Gas final MechanicaUlleating Insulation Certificate Smoke Detectors Stairs, Decks & Landings Final -building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Permit #BLD03-244 •' ; _.,y GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public • Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works aonroval must be received prior to scheduling the Building Deaartment's final inspection 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval arior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 A°`°°ft"°"~~,~ CITY OF PORT TOWNSEND ° DEVELOPMENT SERVICES DEPARTMENT ~ " _ = . ~ • '~~wa~+`~" INSPECTION REPORT PERMIT NUMBER: ~ fi~ ~ 3 ~ ~~ Site Address ,~~~ ~(~S+F'r Con#ractc Owner Date of Inspection u Worksite or Cell Phone# ~~ ~ - ~ fSC~(~ - V~ ^ Erosion/Sediment Control ^ Setbacks/Footings/LIFER ^ Foundation Walls ^ Footing Drainage ^ Slab/Interior Footing/Insulation ^ Groundwork/Plumbing Test ^ Underfloor Framing ^ Ext. Shear Wall/Holdowns ^ Plumbing/Top Out ^ Propane Pipe/Pressure Test ^ Propane Tank/Line ^ Mechanical ^ Framing ^ Insulation ^ Interior Shear/BWP Nail ^ Drywall/Fire Wall ^ Propane/Wood Appliance ^ Manufactured Home Set-up ^ Fire Department ^ Temporary Occupancy ^ Fees Paid Final Occupancy ^ Other/Consultation For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection; for Monday inspections call by 3:00 PM Friday. Additional fees may be assessed for multiple re-inspections if the work is not ready and the inspector must return to the site. Failure to provide inspection record and approved plans on the site will result in $47 re-inspection fee charge. (OCCUPANCY REQUIRES PRIOR WRITTEN APPROVAL BY DSD.) ^ APPROVED ^ APPROVED WITH CORRECTIONS SEE BELOW NOT APPROVED SEE COMMENT(S) BELOW • Approved pans and permit. card must be on-site and available at time of inspection. Inspector ~' _ ~ ~ ~ ~ Date Acknowledged by '~: " - " ~ ©-'-. - '-' Date