CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO3-239 Issued: 11/14/03 Parcel Number: 997 502 006
Job Address: 2910 Kimball Court #1 Zoning: RR=II Type: VV=N Occupancy: RR=3
Total Occupant Load: 4 Nature of Work: Construct Single-family Dwelling
Owner: Kimball Landis LLC Contractor: Kimball Landis LLC KIMBALL996D3
GENERAL CONDITIONS APPLY: See last sage
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF,OTTTRF.n TNCPF.(`TTnNC
A ADU nt7>cn m A m>c
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Matto restrict sediment from leaving
the site See Correction Notice in File ^v
FOOTINGS -per architect's design See Correction Notice in Fil ^
Setbacks ~_ ~ ~~'
Footings ,~, t
Forms
Reinforcement
Interior Footings ~ ,
Porch footings
LIFER
FOUNDATION -per architect's design See Correction Notice in tIP ^
Stem Wall f_ .
Forms
Reinforcement
Anchor Bolts & Washers
Post to Foundation Wall Positive Connection
Holddowns -per engineer design ~
Vents - 8 Required
~. ; 1 --r ~; ,- ~ ~~
CALL 48 hours before`you di~ for Utility line locates
1-800-424-5555
Page 1 of 4
Building Permit #03-239 , "
REQUIRED 1<NSPF,C'Ti(1NC A uDD /1[7L'TT A TT.
- - - ---- -
FLOOR FRAMING +i~v ~ avLi ye-aiav
See Correction Notice in File
NOTE: Engineered BCI floor plan an-site and
available to the Inspector at inspection time , ,
Girders
Joists ~ .l
Blocking ~
Post to Foundation Wall Connection ~?
Positive Connections ~
Treated Wood to Concrete ~
f~
Anchor Bolts & Washers /
Holddowns -per engineer design ~ .
PLUMBING See Correction Notice in File Q'
Rough-In (D-V-T & Clean outs)
Gas supply ,~
Water Supply j
Water Hammer Arrestors V
Hose Bibbs - backflow protection required tt ~
Pipe Insulation (R-3) ~V
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under if electric ., i
~~
Seismic Restraint - 2 places ~
Pressure Relief Valve drain to exterior, terminate
"
"
6
-24
above ground
MECHANICAL See Correction Notice in File ^
Source Specific Exhaust Fans @ bathrooms (SOcfin),
laundry mom, (50 cfin) and kitchen (100 cfin)
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from openings)
Whole house fan - f rst floor bath
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
REQUIRED INSPECTIONS
•
Building Permit #03-239 `
APPR nVFII/n A Tii°.
FRAMING See Correction Notice in File ^
Floor -Engineered BCI plan to be on site at inspection
Walls ~ ;` ;
Sheaz walls -per engineer design , ~ l
Shear Panel Blocking _
Roof -per engineer design ` , ~!;'~
Attic venting -ridge & eave
Posts, beams and headers ';' '
Windows -escape -
Windows -safety glazing .`
Window U-factor - 0.40 or better
Door U-factor - 0.20 or better ~
Skylight U-factor - 0.58 or better
NFRC sticker must be on windows, doors & skylights
at time of inspection
.Air Seal -
Fresh Air Intake -window ports
Fireblocking
Weather Resistive Barrier
INSULATION See Correction Notice in File ^
Floor (R-30 )
Walls (R-21
Ceiling (R-38, attic; R-30, vault)
Baffles
~_. _
Vapor Barrier -paint
DRYWALL NAILING See Correction Notice in File ^
Walls _
'-
Ceiling ~ ~
Concealed space under stairs
FINAL See Correction Notice in File ^
Public Works Sign-off
House Numbers - 5" numbers
Plumbing
Gas final
MechazricaUHeating
Insulation Certificate
Smoke Detectors
Stairs, Decks & Landings
Final -building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Permit #03-239 -•
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's retristration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
-shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works aunroval
must be received arior to schedulin¢ the Buildine Deaartment's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done 6y the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
City of Port Townsend
Development Services Department
Waterman & Katz Building
181 Quincy Street
Port Townsend, WA 98368
(360)379-3208 Fax: (360)385-7576
CERTIFICATE OF OCCUPANCY
BLD03-239
Owner:
Address:
Location:
Building (or portion):
Use(s) permitted:
Kimball Landis
2910 Kimball Court, #1
Port Townsend, WA 98368
Condominium #1
Single-Family Residence
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official. '
Approved: