Loading...
HomeMy WebLinkAboutBLD03-238Waterman & KatzBWldixg 181 QWncy Streek 9Wte 301 Port Taxxaend, WA 98368 Piwoe: 360.379-5086 Fax 360.3857675 u C, J CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-238 Issued: 11/12/03 Parcel Number: 997 502 006 Job Address: 2910 Kimball Court #2 Zoning: RR=II Type: V-N Occupancy: RR=3 Total Occupant Load: 4 Nature of Work: Construct Single-family Dwelling Owner: Kimball Landis, LLC Contractor: Kimball Landis, LLC KIMBALL996D3 GENERAL CONDITIONS APPLY: See last Wage SEPARATE. PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REQUIRED INSPECT70NS A PPR nVF.lll/il A TF TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS -per architect's design _ ~ Setbacks Footings - Forms Reinforcement Interior Footings \1 Porch footings UFER ', FOUNDATION -per architect's design Stem Wall Forms -~~, Reinforcement Anchor Bolts & Washers Post to Foundation Wall Positive Connection `^'^ Holddowns -per engineer design Vents - 8 Required ~~~,.~ .~ - r'z', A i r _ .~ " ~CA~.L 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 4 Building Pemtit ttBLD03-238 RE UIRED INSPECTIONS APPROVED/D TE FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time / ~! Girders ~ Joists ~ Blocking Post to Foundation Wall Connection Positive Connections Treated Wood to Concrete \ Anchor Bolts & Washers ~\ Holddowns -per engineer design PLUMBING Ro -In -V-T & Cle outs y.--~' Z ~~~ ~ ~~~ as supply Water Supply DIC, 3~~6~' ~ ~J Water Hammer Arrestors ose Bibbs - backflow protection required Pipe lnsulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate s 6" -24" above ground MECHANICAL Source Specific Exhaust Fans @ bathrooms (SOcfin), laundry room, (50 cfin) and kitchen (100 cfin) ~t Environmental Air Exhaust ducting (w/ backdraft ~' dampers), insulation (R-4) and terminus (located 3' - ~ ,- ~ from openings) Whole house fan -first floor bath • .J Ca1148 hours before you dig for utility tine locates I-800-424-5555 Page 2 of 4 Building Permit #BLD03-238 • REQUIRED INSPECTIONS APPROVEII/il A TE FRAMING Floor -Engineered BCI plan to be on site at inspection Walls ,.. Shear walls -per engineer design ~ .. _ _' , Shear Panel Blocking Roof-per engineer design ~~, ~~~ _.: ~~'~,. Attic venting -ridge & eave Posts, beams and headers Windows -escape r Windows -safety glazing ? ~ ~ ~ Window U-factor - 0.40 or better ~~~~ "~''~` Q . ~ Door U-factor - 0.20 or better .. Skylight U-factor - 0.58 or better NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake -window ports Fireblocking Weather Resistive Barrier INSULATION Floor (R-30 ) ~ ~~ Walls (R-21) 6 ~~ ~ Ceiling (R-38, attic; R-30 vault) F --~i ~ -~ ~ J ~ Baffles 7/ . ' Vapor Barrier -paint ~ ~ ` / DRYWALL NAILING Walls Ceiling _ ~ ~% Concealed space under stairs ~>a FINAL Public Works Sign-off House Numbers - 5" numbers Plumbing Gas final Mechanical/Heating Insulation Certificate Smoke Detectors Stairs, Decks & Landings Final -building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Permit #BLD03-238 GENERAL CONDTTIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings; sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and' inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required Public Works aoaroval must be received arior to scheduling the Buildine Deaartment's final insoection 7. Final Inspections are required prior to pccupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the Seld. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 >°`oA"°"~s~ CITY OF PORT TOWNSEND PUBLIC WORKS DEVELOPMENT SERVICES DEPARTMENT 9 - 4° ~°Fwas~,~~ INSPECTION REPORT PERMIT NUMBER: ~ ~C> C~ °~ `'~~~~~~~ ~~, ~ ~.{- Address ~1~ ~ ~ ~~ r~ p..F~.~ (~~~,~~LIJ~' Contractor C~ i vrl,~~ ~ `~ ~ 15 Owner Date of Inspection ~ ~ ` ~~ -D-'J Worksite or Cell Phone# ^ Erosion/Sedimentation ^ Setbacks/Footings/LIFER ^ Foundation Walls ^ Slab interior Footing/insulation ^ Groundwork/Plumbing Test ^ Underfloor Framing J Plumbing/Top Out ^ Drywall/Fire Wall Gas Pipe/Pressure Test J Gas/Wood Appliance Prooane Tank/Line ^ Manufactured Home Set-up Mechanical J Public Works Framing J Insulation J Other/Consultation J Shear Wall/Holdowns J Interior Shear/BWP Nail INAL ~ CC~ If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED B/YBUILDING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION ~ APPROVAL ^ CORRECTION REQUIRED ^ APPROVED WITH CORRECTION J NEED APPROVED PLANS & PERMIT ON SITE -- Approved plats and permit card must be on-site and available at time of inspection. ,~ ~, i ~ ~, ~ u ~ ~~ ~'f Inspector_?- _~',~ ~ ___ Date ~~___ City of Port Townsend Development Services Department Waterman & Katz Building 181 Quincy Street Port Townsend, WA 98368 (360)379-3208 Fax: (360)385-7576 CERTIFICATE OF OCCUPANCY BLD03-238 Owner: Kimball and Landis -Umatilla Hill Address: 2910 Kimball Court, #2 Location: Port Townsend, WA 98368 Building (or portion): Condominium #2 Use(s) permitted: Single-Family Residence The above-referenced building or portion complies with the applicable requirements of the Port Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used and occupied in the use and manner indicated above. This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not be removed except by the Building Official. Approved: e. Zf/a.e-dd»~ Permit Technician Date •