HomeMy WebLinkAboutBLD03-238Waterman & KatzBWldixg
181 QWncy Streek 9Wte 301
Port Taxxaend, WA 98368
Piwoe: 360.379-5086 Fax 360.3857675
u
C,
J
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-238 Issued: 11/12/03 Parcel Number: 997 502 006
Job Address: 2910 Kimball Court #2 Zoning: RR=II Type: V-N Occupancy: RR=3
Total Occupant Load: 4 Nature of Work: Construct Single-family Dwelling
Owner: Kimball Landis, LLC Contractor: Kimball Landis, LLC KIMBALL996D3
GENERAL CONDITIONS APPLY: See last Wage
SEPARATE. PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
REQUIRED INSPECT70NS
A PPR nVF.lll/il A TF
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per architect's design _ ~
Setbacks
Footings -
Forms
Reinforcement
Interior Footings \1
Porch footings
UFER ',
FOUNDATION -per architect's design
Stem Wall
Forms -~~,
Reinforcement
Anchor Bolts & Washers
Post to Foundation Wall Positive Connection `^'^
Holddowns -per engineer design
Vents - 8 Required
~~~,.~ .~ - r'z', A i
r _ .~
" ~CA~.L 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
Building Pemtit ttBLD03-238
RE UIRED INSPECTIONS APPROVED/D TE
FLOOR FRAMING
NOTE: Engineered BCI floor plan on-site and
available to the Inspector at inspection time /
~!
Girders ~
Joists ~
Blocking
Post to Foundation Wall Connection
Positive Connections
Treated Wood to Concrete \
Anchor Bolts & Washers ~\
Holddowns -per engineer design
PLUMBING
Ro -In -V-T & Cle outs y.--~'
Z ~~~ ~ ~~~
as supply
Water Supply DIC, 3~~6~' ~ ~J
Water Hammer Arrestors
ose Bibbs - backflow protection required
Pipe lnsulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under if electric
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate s
6" -24" above ground
MECHANICAL
Source Specific Exhaust Fans @ bathrooms (SOcfin),
laundry room, (50 cfin) and kitchen (100 cfin) ~t
Environmental Air Exhaust ducting (w/ backdraft ~'
dampers), insulation (R-4) and terminus (located 3' - ~
,- ~
from openings)
Whole house fan -first floor bath
•
.J
Ca1148 hours before you dig for utility tine locates
I-800-424-5555
Page 2 of 4
Building Permit #BLD03-238
•
REQUIRED INSPECTIONS
APPROVEII/il A TE
FRAMING
Floor -Engineered BCI plan to be on site at inspection
Walls
,..
Shear walls -per engineer design ~ ..
_ _' ,
Shear Panel Blocking
Roof-per engineer design ~~, ~~~ _.: ~~'~,.
Attic venting -ridge & eave
Posts, beams and headers
Windows -escape r
Windows -safety glazing ?
~
~
~
Window U-factor - 0.40 or better ~~~~
"~''~` Q
.
~
Door U-factor - 0.20 or better ..
Skylight U-factor - 0.58 or better
NFRC sticker must be on windows, doors & skylights
at time of inspection
Air Seal
Fresh Air Intake -window ports
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
~
~~
Walls (R-21) 6
~~
~
Ceiling (R-38, attic; R-30 vault) F --~i
~ -~ ~ J
~
Baffles 7/
. '
Vapor Barrier -paint ~
~ `
/
DRYWALL NAILING
Walls
Ceiling _ ~ ~%
Concealed space under stairs ~>a
FINAL
Public Works Sign-off
House Numbers - 5" numbers
Plumbing
Gas final
Mechanical/Heating
Insulation Certificate
Smoke Detectors
Stairs, Decks & Landings
Final -building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Permit #BLD03-238
GENERAL CONDTTIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's re¢istration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings; sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and' inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required Public Works aoaroval
must be received arior to scheduling the Buildine Deaartment's final insoection
7. Final Inspections are required prior to pccupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the Seld. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
>°`oA"°"~s~ CITY OF PORT TOWNSEND PUBLIC WORKS
DEVELOPMENT SERVICES DEPARTMENT
9 - 4°
~°Fwas~,~~ INSPECTION REPORT
PERMIT NUMBER: ~ ~C> C~ °~ `'~~~~~~~ ~~, ~ ~.{-
Address ~1~ ~ ~ ~~ r~ p..F~.~ (~~~,~~LIJ~'
Contractor C~ i vrl,~~ ~ `~ ~ 15
Owner
Date of Inspection ~ ~ ` ~~ -D-'J
Worksite or Cell Phone#
^ Erosion/Sedimentation
^ Setbacks/Footings/LIFER
^ Foundation Walls
^ Slab interior Footing/insulation
^ Groundwork/Plumbing Test
^ Underfloor Framing
J Plumbing/Top Out ^ Drywall/Fire Wall
Gas Pipe/Pressure Test J Gas/Wood Appliance
Prooane Tank/Line ^ Manufactured Home Set-up
Mechanical J Public Works
Framing
J Insulation
J Other/Consultation
J Shear Wall/Holdowns J Interior Shear/BWP Nail INAL ~ CC~
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED B/YBUILDING AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION ~ APPROVAL ^ CORRECTION REQUIRED
^ APPROVED WITH CORRECTION J NEED APPROVED PLANS & PERMIT ON SITE
--
Approved plats and permit card must be on-site and available at time of inspection.
,~
~, i ~ ~, ~ u ~ ~~ ~'f
Inspector_?- _~',~ ~ ___ Date ~~___
City of Port Townsend
Development Services Department
Waterman & Katz Building
181 Quincy Street
Port Townsend, WA 98368
(360)379-3208 Fax: (360)385-7576
CERTIFICATE OF OCCUPANCY
BLD03-238
Owner: Kimball and Landis -Umatilla Hill
Address: 2910 Kimball Court, #2
Location: Port Townsend, WA 98368
Building (or portion): Condominium #2
Use(s) permitted: Single-Family Residence
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Approved:
e. Zf/a.e-dd»~
Permit Technician Date
•