HomeMy WebLinkAboutBLD03-235Waterman & Kalz Building 181 QWncy 9treey Suite 301 Pout Townsend, WA 98368 Phone: 368-379-5086 Fax 360.3857675 CITY OF PORT TOWNSEND Permit Number: BLD03-235 Issued: 11/17/03 Job Address: 2910 Kimball Court #i12 Zoning: R-II fPUDI Total Occupant Load: 2 Owner: Umatilla Hill Occupancy: S_2 Nature of Work: Construct 10-unit Storage Room Contractor: Kimball Landis LLC GENERAL CONDITIONS APPLY• See last oa es SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 UMATILLA HILL PUD RESTRICTIONS APPLY including limifing outdoor construction on the site to the hours of 7 AM to 6 PM Monday through Friday, and prohibited on Saturdays, Sundays, and National Holidays. Any exceptions made necessary by special and unusual circumstances must be approved in advance by the Building Official. RF.nTTTRF,TI TN.cPF.("TTnNC - - - - - - - - TEMP EROSION & SEDIMENT CONTROL aw ~ nail L~ a . ~. See Correction Notice in File ^ See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS SeQ'Cnrr~ction Notlee in Fdle C?" Setbacks- reducfions are on file , Footings Forms Repforcement Interior Footings UFER SLAB ON GRADE ~ a 4" slab with #3 rebar placed at 30" o.c. over 2" of ~ _~ ~ sand, over 6 mil plastic, over 3" pea gravel ~~.--. ~ ~ ,- - 12" wide b 8" dee thickened interior footin Parcel Number: 997-502-006 CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 3 Building Pemut #BLD03-235 RE UIRED INSPECTIONS APPROVED/DATE FOUNDATION See Correction Notice in File ^ .Stem Wall Forms Reinforcement Anchor Bolts & Washers EXTERIOR SHEATHING See Correction Notice in File ^ NOTE: Do not cover prior to inspection Special one- hour construction required on East and -West walls due to proximity to Property lines 5/8" Type "X" Gypsum applied parallel to exterior 2x4 studs with galvanized roofing nails 1 '/a" long, 0.120" shank, 7/16" or'/z" heads 7" o.c. field and 4" o.c. perimeter. Wallboard and sheathing nailed to top & bottom plates at 7" o.c. FRAMING See Correction Notice in Fide ^ Walls CDX at partition walls Porch overhang Trusses -Engineered truss plan to be on-site at time of inspection Attic venting -gable & eave Window U-factor - 0.40 or better Door U-factor - 0.20 or better Air Seal Weather Resistive Barrier DRYWALL NAILING See Correction Notice in File ^ Special one-hour wall construction required on East and West walls due to proximity to property lines 5/8/" type "X" gypsum applied pazallel with or at right angles to 2x4 exterior walls, with 6d coated nails with 1- 7/8" long 0.0915" shank and '/"heads at 7" o.c. Walls Ceiling '~N~' See Correction Notice in File ^ Public Works Sign-off House Numbers - 5" numbers Landings Final -building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 r ~~~ Building Pemu[ #BLD03-235 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (1'ESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correcfion of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass £mal inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is reauired. Public Works auproval must be received urior to scheduling the Buildin¢ Department's £mal insuCCfion 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 3'79-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. ~J Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 °~'°RrT°""sF CITY OF PORT TOWNSEND PUBLIC WORKS U DEVELOPMENT SERVICES DEPARTMENT 9 _ GAO F°FWASH~~ INSPECTION REPORT 1~ ~3 ~~ 2 ~ S^' PERMIT NUM,BQE~R~~G~ tM Addres~'~o~~7 ~--- ~I 1 Contractor Owner Date of Inspection Worksite or Cell Phone# ^ Erosion/Sedimentation ^ Setbacks/Footings/LIFER Foundation Walls ~] Slab Interior Footing/Insulation Groundwork/Plumbing Test ^ Underfloor Framing r1 LJ 2q ~ o ,~,,~all Cf, ~~-e -~~uCI ~ C,~,.d., ~? dL LI Plumbing/Top Out ^ Gas Pipe/Pressure Test ^ Propane Tank/Line ^ Mechanical ^ Framing ^ Insulation ^ Drywall/Fire Wall ^ Gas/Wood Appliance Manufactured Home Set-up ^ Public Works ^ Other/Consultation ^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail ~NAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 6:00 AM. NO OCCUPANCY UNTIL FINALIZED BY B ILDING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION - PPROVAL J CORRECTION REQUIRED APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE Approved plans Inspector I permit card must be on-site and available at time of inspection. ~S~:r ~_ Date, ,<