HomeMy WebLinkAboutBLD03-233r~
n
LJ
r1
\J
•
Waterman & ICah 13atlding
181 QWucy Street, SW[e 301
Port Towneeod, WA 98368
PMae: 360.379-5086 Fax360.3857675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-233 Issued: 10/29/03 Parcel Number: 972 600 705
Job Address: 1810 31`" Street Zoning: RR=II Type: VV=N Occupancy: R_3
Total Occupant Load: 3 Nature of Work: Construct Sinele-family Dwellin¢
Owner: O. John Needham Contractor: Owner
GENERAL CONDITIONS APPLY: See last aa¢e
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF.fITTTRF.l1 TNCPF.f'TTl1NC
A PUUl1VL`T/tl A TL'
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
F ~IN6~
etbacks '
Footin s r -1.~..-~' -4 ~.~
~
`
Forms -- -_I_.
-~------.~
-
Reinforcement
Interior Footings
Porclt~ootings
~7FE1Z }
_ _
<
FOUNDATION _ _ _
Stem Wall _ __ -
Forms
Reinforcement -
Anehor Bolts & Washers
Post to Foundation Wart Positive Connection
Holddowns
Vents -10 Required ~ '
,y
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
.~
Building Permit k03-233
~~~k
vl`~~
REQUIRED INSPEC'TinNS evvunirGnm~m>c
- _ _ _
FLOOR FRAMING
NOTE: Engineered BCI floor plan on-site and
available to the Inspector at inspection time
Girders
Joists
Blocking
Post to Foundation Wall Connection '~
Positive Connections , P~
Treated Wood to Concrete ~
Anchor Bolts & Washers ~\ ,J
Holddowns aii aia~ i aJ
I
, ~,_ 1
~j
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply ~ LL\
Water Hammer Arrestors C ~1
LPG Gas Supply
Hose Bibbs - backflow protection required
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater ~~'
R-10 under if electric
Seismic Restraint - 2 places ~
Pressure Relief Valve drain to exterior, terminate ~'
6" -24" above ground ~
ME HANICAL
G Stove -provide specs on-site
Manufacturer's installation instructions to be on-site
@ time of inspection.
Source Specific Exhaust Fans @ bathrooms (SOcfin),
laundry room, (50 c&n) and kitchen (100 cfin)
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from openings)
Whole house fan -Master Bath
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Building Permit #03-233
•
U
n
REQUIRED INSPECTIONS
A PPR f)VFT)/il D TF
FRAMING ------- -- ----
Floor
Walls
Holddowns ~`~
Shear walls ~ ~
Shear Panel Blocking ~
Roof -Engineered truss plan to be on-site at time of
inspection
~
Attic venting- ridge & eave ~~,' "~
Posts, beams and headers
Windows -escape
Windows -safety glazing
Window U-factor - 0.40 or better
Door U-factor - 0.20 or better
Skylight U-factor - 0.58 or better
NFRC sticker must be on windows, doors & skylights
at time of inspection
Air Seal
Fresh Air Intake -Wall Ports
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-~
Ceiling (R-38, attic; R-30 vault)
Baffles
Vapor Barrier -paint
DRYWALL NAILING
Walls
Ceiling
FINAL
Public Works Sign-off
House Numbers - 5" numbers
Plumbing
LPG
Mechanical/Heating
Insulation Certificate
Smoke Defectors
Stairs, Decks & Landings
Final -building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Pertlrt[ #03-233
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required Public Works aanroval
must be received prior to scheduling the Building Department's fmal inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All .building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
n,"{ ..
r~,
(,
.~
°`"p0.Tip"~sm CITY OF PORT TOWNSEND PUBLIC WORKS
° BUILDING AND COMMUNITY DEVELOPMENT
9~O~WpSM~°~ INSPECTION REPORT
PERMIT NUMBER: '~U)~ ~ _ ~~~
Address I~ ~1 ~ 3 ~ s f` S~.
Contractor 1~11~~ i~~t-t-Lf 1\L2"~~-~
Owner
Date of Inspection
~l~rlc
Worksite or Cell Phone#
^ Erosion/Sedimentation ^ Plumbing/Top Out ^ Drywall/Fire Wall
^ Setbacks/Footings/UFER ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance
^ Foundation Walls ^ Propane Tank/Line ^ Manufactured Home Set-up
^ Slab Interior Footing/Insulation ^ Mechanical ^ Public Works
^ Groundwork/Plumbing Test ^ Framing ^ Other/Consultation
^ Underfloor Framing ^ Insulation
^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail FINAL
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED 8Y BUILDING AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION ]APPROVAL J CORRECTION REQUIRED
i .,
~~ ~." -
--~.
._
,,
~,- ~ t : ,~ +-~ :"
/T /~, ~ _ nk {.
x
r
- v ~!
'. i 1 ~ r.
~f Li ~ ~
~.
~.__~.~ ~~' r-
,~- t--'
_ ... f
_, ., - -
i ~ ;, ,
,~--- / _
~, ; ,
~ -
__
,_ T ,~ -
_~.,
-- ,:
Approved plans and permit card must be on-site and available at time of inspection.
'~ ~ ` L r-
' c,
Inspector ~- Date