Loading...
HomeMy WebLinkAboutBLD03-232 CITY OF PORT TOWNSEND • CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO3-232 Issued: 11/13/03 Parcel Number: 972 903 102 Job Address: 5498 Hendricks Street Zoning: R_II Type: VV=N Occupancy:. RR=3 Total Occupant Load: 5 Nature of Work: Construct Single-family Dwelling Owner: Karen A,R Mueller Contractor: Owner -See General Condition #1 GENERAL CONDITIONS APPLY: See last aaEe SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REQUIRED iNSPF.C'TiONS A PPR (lVEil/Il ATF. TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site See Correction Notice in File FOOTINGS See Correction Notice in File Setbacks Footings Forms Reinforcement ~~ ~ ~ Interior Footings / / '~ ~ Porch footings ~'~ LIFER FOUNDATION See Correction Notice in File Stem Wall Forms ~[, R i f t ~ e n orcemen , ~ ~ Anchor Bolts & Washers Post to Foundation Wall Positive Connection // -. Cc `~/~' ~ Holddowns -per engineer design LLL i1 . / Vents - 9 Required ~ l/ • Building Permit #BLD03-232 REQUIRED INSPECTinNS a nuunv~nm w m>c - - ---- - FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time Girders Joists Blocking Post to Foundation Wall Connection Positive Connections Treated Wood to Concrete Anchor Bolts & Washers Holddowns -per engineer design a. a.v• ~ui yt~al~ See Correction Noti in File ~! v~ ~ L~ L Q'j / [/ / PLUMBING See Correction Notice in File A Licensed Plumber in good standing with Washington State Labor and Industries must do this work. j 4 Rough-In (D-V-T & Clean outs) ,~~~ Gas supply (y Water Supply V Water Hammer Arrestors Hose Bibbs - backflow protection required j Pipe Insulation (R-3) ~~ Pressure Reduction Valve if> 80 psi Water Heater R-10 under if electric ~1 Seismic Restraint - 2 places `v Pressure Relief Valve drain to exterior, terminate " " 6 -24 above ground MECHANICAL See rrection Notice in File Source Specific Exhaust Fans @ bathrooms (SOcfrn), , laundry room, (50 cfin) and kitchen (100 cfin) ~ `~ Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whole house fan -second floor bath ~'1 • Building Permit MBLD03-232 REQUIRED INSPECTIONS arrunvF.nmeTF • FRAMING See Correction Notice in File Floor -Engineered BCI plan to be on site at inspection Walls Sheaz walls -per engineer design Shear Panel Blocking Roof Ridge Beam -per engineer design Attic venting -ridge c~ eave Posts, beams and headers -per engineer design Windows -escape Windows -safety glazing Window U-factor - 0.40 or better Door U-factor - 0.20 or better j Skylight U-factor - 0.58 or better NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake -window ports Fireblocking ~ Weather Resistive Barrier INSULATION See CorrectiomlVotice in File Floor (R-30) Walls (R-21 Ceiling (R-38, attic; R-30, vault) Baffles ~- Vapor Barrier -paint DRYWALL NAILING See Correction Notice in File Walls Ceiling Concealed space under stairs FINAL See Correction Notice in File Public Works Sign-off L&I Electrical Sign-off House Numbers - 5" numbers Plumbing Gas final Mechanical/Heating Insulation Certificate Smoke Detectors Stairs, Decks & Landings Final -building r1 Building Permit #BLD03-232 GENERAL CONDTTIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reEistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5, Re-inspection is required after inspection report corrections are completed: 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours n~tire is remi:rad PnhL't. wr..4c q.,.......Ai 7. .Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All. building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • City of Port Townsend Development Services Department Waterman & Katz Building l81 Quincy Street Port Townsend, WA 98368 (360)379-3208 Fax: (360)385-7576 Owner: Address: Location: Building (or portion): Use(s) permitted: • CERTIFICATE OF OCCUPANCY BLD03-232 Karin Mueller 5498 Hendricks Street Port Townsend, WA 98368 Single Family Residence R-3 The above-referenced building or portion complies with the applicable requirements of the Port Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used and occupied in the use and manner indicated above. This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not be removed except by the Building Official. u/~,rs-4Yr~- Approved: Permit Technician Date n LJ