HomeMy WebLinkAboutBLD03-229a r ,. CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDO3-229 Issued: 11/17/03 Parcel Number: 948-004-208 Job Address: 1466 30`° Place Zoning: RR=2 Type: VV=N Occupancy: R_3 Total Occupant Load: 7 Nature of Work: Addition of 720 square feet- Livineroom and laundry at first floor, bedroom above Owner: Sindi Pladsen Contractor: Owner GENERAL CONDITIONS APPLY: See last paces SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REQUIRED INSPECTIONS APPROVED/DATF, TEMP EROSION & SEDIMENT CONTROL See See Correction Notice in File ^ General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS See Correction Notice in File ^ Setbacks Footings ,. Forms ~ Reinforcement ,,~ Interior Footings UFER - FOUNDATION See Correct on Notice in File ^ Stem Wall Forms Reinforcement Anchor Bolts & Washers Vents -3 Re uired EXTERIOR SHEATHING See Correction Notice in File ^ NOTE: Do not cover prior to inspection Braced Wall Panel Design i (~,/ ~~` ,~f ~~ ~-~ ~ ~~~~~\~ Building Permit #BLD03-229 ~- REOUIl+CI~:D TNSPF,("TT(1NC snuun~~nm s m~ - - - MECHANICAL a a acv ~ a.:,air La'i a u See Correction Notice in File D `~ Source Specific Exhaust Fans @ laundry room, (50 cfin) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) FRAMING See Correction Notice in File ^ Prescrivtive & designed braced wall Hanel sheathi~ & nailing must be inspected prior to cover Floor -Engineered BCI plan to be on site at inspection r_. f ~ ,~~ ~~ Walls Trusses -Engineered truss p an to be on-site atlime of inspection ~~ t Attic venting -gable & eave ! Posts, beams and headers ~,,. ~ Windows -escape ~ ~. Windows -safety glazing Window U-factor - 0.40 or better Door U-factor - 0.20 or better / NFRC sticker must be on windows, doors & skylights 7_`/ at time of inspection Air Seal Window Ports Spiral staircase- per UBC 1003.3.3.8.3 Fireblocking Weather Resistive Barrier INSULATION See Correction Notice in iFile ^ Floor (R-30) backed batts Walls (R-21) face t l d b k d b tt ~% s ap e , ac e a s ; Ceiling (R-38, attic; R-30 vault) Baffles , ~ x' - Z- `) ~ , ~, } DRYWALL NAILING See orrection Notice in File ^ Walls Ceiling U `~ 2 ~- FINAL See Correction Notice in File ^ Public Works Sign-off House Numbers - 5" numbers Plumbing Mechanical/Heating Insulation Certificate Smoke Detectors -also required to update existing structure Decks & Landings Final -building `, J Building Permit #BLD03-229 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required Public Works annroval must be received arior to scheduline the Buildine Deaartment's final insuection 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. r1 CJ °~°°p"°"~sF CITY OF PORT TOWNSEND PUBLIC WORKS & ° DEVELOPMENT SERVICES DEPARTMENT __ 9~FOFWASN~~°~ INSPECTION REPORT ~ PERMIT NUMBER: ~LC~(7~j ~ ~2~ ~~ Address ~ ~~ ~~~ Contractor Owner ~ ( ~ efl Date of Inspection ~ - ~ - ~~~ C J Worksite or Cell Phone# Erosion/Sedimentation ^ Setbacks/Footings/LIFER ^ Foundation Walls ^ Slab Interior Footing/Insulation ^ Groundwork/Plumbing Test ^ Underfloor Framin 3 ~ .~~ 3 PlumbinglTop Out ^ Drywall/Fire Wall Gas Pipe/Pressure Test ^ Gas/Wood Appliance .1 Propane Tank/Line ^ Manufactured Home Set-up ^ Mechanical ^ Public Works ^ Framing ^ Insulation :] Other/Consultation 9 Shear Wall/Holdowns ^ Interior Shear/BWP Nail ~INAL If corrections required, re-inspection must b done prior to covennng or concealing areas of construction. Additional fees may be as essed for multiple re-inspections. For Re-inspection, call Inspection Mess a Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED BUILDING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION APPROVAL ^ CORRECTION REQUIRED ^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE • Approved plans Inspector be on-site and available at time of inspection. Date