HomeMy WebLinkAboutBLD03-229a
r
,.
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO3-229 Issued: 11/17/03 Parcel Number: 948-004-208
Job Address: 1466 30`° Place Zoning: RR=2 Type: VV=N Occupancy: R_3
Total Occupant Load: 7 Nature of Work: Addition of 720 square feet- Livineroom and
laundry at first floor, bedroom above
Owner: Sindi Pladsen Contractor: Owner
GENERAL CONDITIONS APPLY: See last paces
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
REQUIRED INSPECTIONS
APPROVED/DATF,
TEMP EROSION & SEDIMENT CONTROL See See Correction Notice in File ^
General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS See Correction Notice in File ^
Setbacks
Footings
,.
Forms ~
Reinforcement ,,~
Interior Footings
UFER -
FOUNDATION See Correct on Notice in File ^
Stem Wall
Forms
Reinforcement
Anchor Bolts & Washers
Vents -3 Re uired
EXTERIOR SHEATHING See Correction Notice in File ^
NOTE: Do not cover prior to inspection
Braced Wall Panel Design
i
(~,/
~~` ,~f ~~ ~-~ ~ ~~~~~\~ Building Permit #BLD03-229 ~-
REOUIl+CI~:D TNSPF,("TT(1NC snuun~~nm s m~
- - -
MECHANICAL a a acv ~ a.:,air La'i a u
See Correction Notice in File D `~
Source Specific Exhaust Fans @ laundry room, (50 cfin)
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3' from
openings)
FRAMING See Correction Notice in File ^
Prescrivtive & designed braced wall Hanel sheathi~
& nailing must be inspected prior to cover
Floor -Engineered BCI plan to be on site at inspection r_. f ~ ,~~ ~~
Walls
Trusses -Engineered truss p an to be on-site atlime of
inspection ~~
t
Attic venting -gable & eave !
Posts, beams and headers ~,,. ~
Windows -escape ~ ~.
Windows -safety glazing
Window U-factor - 0.40 or better
Door U-factor - 0.20 or better /
NFRC sticker must be on windows, doors & skylights 7_`/
at time of inspection
Air Seal
Window Ports
Spiral staircase- per UBC 1003.3.3.8.3
Fireblocking
Weather Resistive Barrier
INSULATION See Correction Notice in iFile ^
Floor (R-30) backed batts
Walls (R-21) face
t
l
d
b
k
d b
tt
~%
s
ap
e
,
ac
e
a
s ;
Ceiling (R-38, attic; R-30 vault)
Baffles ,
~ x'
- Z- `)
~ ,
~, }
DRYWALL NAILING See orrection Notice in File ^
Walls
Ceiling U `~
2 ~-
FINAL See Correction Notice in File ^
Public Works Sign-off
House Numbers - 5" numbers
Plumbing
Mechanical/Heating
Insulation Certificate
Smoke Detectors -also required to update existing
structure
Decks & Landings
Final -building
`,
J
Building Permit #BLD03-229
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's reeistration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required Public Works annroval
must be received arior to scheduline the Buildine Deaartment's final insuection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
r1
CJ
°~°°p"°"~sF CITY OF PORT TOWNSEND PUBLIC WORKS &
° DEVELOPMENT SERVICES DEPARTMENT __
9~FOFWASN~~°~ INSPECTION REPORT ~
PERMIT NUMBER: ~LC~(7~j ~ ~2~ ~~
Address ~ ~~ ~~~
Contractor
Owner ~ ( ~ efl
Date of Inspection ~ - ~ - ~~~
C J
Worksite or Cell Phone#
Erosion/Sedimentation
^ Setbacks/Footings/LIFER
^ Foundation Walls
^ Slab Interior Footing/Insulation
^ Groundwork/Plumbing Test
^ Underfloor Framin
3 ~ .~~ 3
PlumbinglTop Out ^ Drywall/Fire Wall
Gas Pipe/Pressure Test ^ Gas/Wood Appliance
.1 Propane Tank/Line ^ Manufactured Home Set-up
^ Mechanical ^ Public Works
^ Framing
^ Insulation
:] Other/Consultation
9
Shear Wall/Holdowns ^ Interior Shear/BWP Nail ~INAL
If corrections required, re-inspection must b done prior to covennng or concealing areas
of construction. Additional fees may be as essed for multiple re-inspections.
For Re-inspection, call Inspection Mess a Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED BUILDING AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION APPROVAL ^ CORRECTION REQUIRED
^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE
•
Approved plans
Inspector
be on-site and available at time of inspection.
Date