HomeMy WebLinkAboutBLD03-228Wateman &. Katz Bwlding
181 Quincy Sheet Suice 301
PoR To.~msmM, WA 98368
Phone (360) 379-3208 Fax (360) 3B5-7675
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO3-228 Issued: 10/16/03 Parcel Number: 984 900 301
Job Address: 804 F Street Zoniug: RR=II Type: VV=N Occupancy: R-3
•
Total Occupant Load: No Change Nature of Work: Reoair/Remodel existing deck, stairs and railings.
Owner: Mvrtle Harhvick Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RF,OTTTRF.TI TNCPF.('Ti(1NC
A DPDl1[7T. T /il A TL+
- --._
FOOTINGS
Setbacks ~ ~
Deck Pier Footings `
Reinforcement •_____.-. ..~~. Y.~~..
_
FLOOR FRAMING/DECK
All framing members to be pressure treated ar wood of ~~
natural resistance to decay 1
Posts
Beam ^' .
Joists (2" x 8"@ 16" o.c.) `
Positive Connection ~
;
Post-to-Pier ,
Post-to-Beam
Treated Wood to Concrete
Lag Bolts @ ledger -See red-lines on plans for size and
spacing
Blocking
FINAL
House Numbers posted (minimum 5")
Guardrails
Handrails
Stairs
Landing
Smoke Detectors throughout existing construction per 1997
UBC
Deck -Final
C
Ca1148 hours before you dig utility line locates: 1-800-424-5555
Page 1 of 2
Prnmt # BLD03-228
GENERAL CONDITIONS
1
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shot down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled "
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
ezposed daring construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc, once construction is complete.
Appiicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alteruate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required Public Works anoroval-must be received prior to
scheduling the Baildine Deuartment's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- a
residential project.
8. AB building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department withiu one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WTTH THE APPROVED PLANS.
Call 48 hours before you dig utility line locates: 1-800-424-5555
Page 2 of 2
Ii~~SP1:C'1'IO\T li1:POli'1'
NAME
Permit Nc'~'7 -' G- Z'~
~.
,/ ~,y'A.r'4 /
~ ~ l y 4%~~ ~L/
70 NOT REMOVE THIS TAG
Date ~- '(./ y ~ L
CITY OF PORT TOWNSEND, BUILDING & COMMUNITY DEVELOPMENT
WATERMAN & KATZ BUILDING, 181 OUINCY ST, SUITE 301, PORT TOWNSEND, WA 98368 (360) 379-3208
YOU ARE HEREBV NOTIFIED THAT NO MORE WORK SHALL BE COVERED UPON THESE PREMISES UNTIL THE ABOVE VIOLATIONS ARE CORRECTED.
WHEN CORRECTIONS HAVE BEEN MADE, CALL FOR REINSPECTION AT 385-2294.
YOU MAY APPEAL DECISIONS OF THE BUILDING OFFICIAL TO THE BOARD OF APPEALS WITHIN 15 DAYS OF INSPECTION DATE.
FOR FURTHER INFORMATION CONTACT BCD AT (360) 379-3208