Loading...
HomeMy WebLinkAboutBLD03-227 Waterman & Ifah Building 181 Qnincy Street, Suite 301 Port Townsend, WA 98368 Phone: 360J79•5086 Fax 3603857675 U LJ CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDU3-227 Issued: 10/09/03 Parcel Number: 985 800 201 Job Address: 1905 Willow Street Zoning: R_II Type: V_N Occupancy: RR=3 Total Occupant Load: N/C Nature of Work: Convert ¢araEe to bedroom, bath & laundry Owner: Brandon Brolliar Contractor: Discovery Bay Construction - DISCOBC09089 GENERAL CONDITIONS APPLY: See last page SEPARATE PERMITS REOUHtED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REQUIRED INSPECTIONS APPRnVFn/IIATF. GROUNDWORK PLUMBING Pressure Test Pipe Joints Exposed Pipe Bedding ~ F; +~. (•' ~- + ~~ l PLUMBING Rough-In (D-V-T & Clean outs) Water Supply ~7 = ~ ~ ' ' Water Hammer Arrestor & clothes washer / ;~ Pipe Insulation (R-3) `` ' , MECHANICAL ' Source Specific Exhaust Fans @ bathroom (SOcfm) , and laundry room (50 cfm) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' \ from openings) CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 3 Building Permit N03-227 REQUIRED INSPECTIONS APPRnvF.nmeTF FRANIING Walls Beams and headers ~ ,. Windows -escape Windows -safety glazing ~ Window U-factor - 0.35 or better ~' NFRC sticker must be on windows at time of Z/' Inspection Attic Access Air Seal Fireblocking @ floor sleepers !~ ' Weather Resistive Barrier @ new exterior framing J INSULATION Slab perimeter (R-10) Walls (R-13) Ceiling (R-38 entire ceiling of existing house)(1 ~ Baffles I / V Vapor Barrier required - e.g., faced batt~V;B. patnt DRYWALL NAILING ~ ~ j Walls u ~ G~,~ Ceiling ~~ ~~ FINAL Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground House Numbers - 5" numbers Plumbing Mechanical Insulation Certificate Vapor Barrier Paint Certificate (if applicable) Smoke Detectors throughout existing construction: one in each sleeping room and in each area leading to sleeping rooms Final -building Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 } Building Permit N03-227 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works aonroval must be received urior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3