HomeMy WebLinkAboutBLD03-223CITY OF PORT TOWNSEND
Permit Number: BLD03-223
Job Address: 837 McPherson Street
Issued: 11/10/03
Total Occupant Load: 3 Owner: Ken Kelly
Occupancy: R-3
Contractor: Same as Owner
Nature of Work: Construct foundation for moved house (see MIS03-032 for movine permit)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,OiTiRF,D iNSPF,C'TiONS
APPRnVF,D/I)ATF.
TEMPORARY EROSION & SEDIMENT CONTROL
ee General Condition No. 2 -install on-site as needed during
construction to prevent sediment from leaving and site and to
eliminate tracking of soil onto the street.
FOOTINGS
Setbacks '~; ~
Footings
Interior Footings .'!
Forms
i
'Reinforcement ~ v
LIFER / "
FOUNDATION
Stem Wall
Forms ` ~ t
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" square washers
I
Positive Connections
Call 48 hours before you dig for utility Gne locates
1-800-424-5555
Page 1 of 3
Zoning: R_II
Wateman &. Katz Buildwg
181 Qidncy Street, Suile 301
Port rownsend W A 98368
Phone: (360) 344-3057 Fax: (360) 385-7675
Parcel Number: 948 332 202
1
Pemdt k BLD03-223
REQUIRED iNSPF,('TinNC eppunvFnmsrr>~
FLOOR FRAMING/CRIPPLE WALL FRAMING
NOTE: Street and Utility Development Permit shall be issued ~ ~
and available to the Inspector on-site at time of inspection ~~ ~Ti-7 O~
Girder Beam
Beam Pockets
Beam to Concrete
Treated Posts
Shield under Posts
Treated Plates
Anchor Bolts & Washers
Positive Connections
Blocking
Crawl Access
Foundation Vents -10 required
INSULATION
Fill existing floor joist cavities
FINAL
Public Works Sign-off
House Numbers -minimum 5"
Smoke Detectors throughout existing construction -one in
each sleeping roam and in each area leading to sleeping
rooms
6 mil black poly in crawl space -lap seams 12 "
Final -building
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number. and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning constriction; call 385-2294. Measures shall include installation of silt fencing hnd graveled
construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) regaire inspection prior to cover.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Pertmt # BLD03-223
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11 3 85-2 2 94. A
minimum of twenty-four hours notice is required Public Works auaroval must be received prior to
schedalin¢ the Buildine Deuartment's final insaection.
7. Final Inspections are required prior to occupancy; A Cert~cate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep yoar
banding permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
°``°aT'°"~sm CITY OF PORT TOWNSEND PUBLIC WORKS
p° BUILDING AND COMMUNITY DEVELOPMENT
~OFWPSN~~Cf INSPECTION REPORT 22
PERMIT NUMBER: C~ L)~ O 3' .Z ~ J
Address tS ~~ ~~ ~ ~h P r~S~n
Contractor
Owner
~ ~ ~ ~"~'
Date of Inspection r
Worksite or Cell Phone # ~ ~ U ~ S /~ -, 2
^ Erosion/Sedimentation ^ Plumbin /Top Out ^ Drywall/Fire Wall
'^ Setbacks/Footings/LIFER ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance
^ Foundation Walls ^ Propane Tank/Line ^ Manufactured Home Set-up
^ 51ab Interior Footing/Insulation ^ Mechanical ^ Public Works
Groundwork/Plumbing Test gaming ^ Other/Consultation
^ Underfloor Framing ^ Insulation
^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail ^ FINAL
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
• For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED BY BUILDING AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION I~APPROVAL ^ CORRECTION REQUIRED
~.
Approved plans an¢ p and must be on-site and available at time of inspection.
Inspector ' ~, ~ . ~ = ~' ~ '~ _ _- _ ~ _ Date ,?=?~l
1 I~-_~? ,