Loading...
HomeMy WebLinkAboutBLD03-207Waterman & Katz 13uildiog 181 Quincy Skeet, Suite 301 PoK TownseoQ WA 98366 Phone: (360)344-3057 Fax: (360)365-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDO3-2O7 Issued: 10/09/03 Parcel Number: 989 700 401/403 Job Address: 400 Water Street Zoning: C=III Type: VV=N Occupancy: AA=3 Nature of Work: New maritime dock, platform, ramp, etc, and demolition of existin¢ dock and shed Owner: City of Port Townsend/Northwest Maritime Center Contractor: Caicos Corp. CAICOC*161RL GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: Special Inspection is required for all structural welding, 6, 000 psi concrete and A325 high strength bolting, as required by UBC Section 1701.5. Special Inspector shall be a Washington licensed .engineer or ICBO certif ed inspector. ICBO certified inspector to either b e listed in the current edition of WABO ~v and Inspector Re i~ or present credentials to the Building Department prior to performing inspections. Reguired Special Inspection Reports shall indicated compliance with the plans and specifications and shall be copied to the Building Department in a timely manner. Permit Holder or Permit Holders' Agent shall review and oversee correction of any and all deficiencies noted by required special inspections. Hours o/'construction shall be limited to 7 a.m. to 6 p.m.. Monday through Friday and prohibited on weekends and national holidays. EROSION & SEDIMENT CONTROL Temporary erosion and sediment control measures shall be installed on-site as per approved plan during construction through the use of ftlter fence to contain dirt and sediment on- site. Adjacent rights-of--way shall be kept clean through sweeping of paved surfaces, tire wash, etc. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 5 c«,~u aet,DO3-zoo RE UIRED INSPECTIONS APPROVED/DATE SAFETY PLAN A site-specific safety plan will be prepazed for use by all workers at the site during remedial activities. The site will be secured to prevent entry of unauthorized persons. The contractor is required to comply with the safety requirements of all government agencies, including Occupational Safety and Health Administration (OSHA) and Washington State Department of Labor and Industries (L&I), for excavation safety and for operations at hazardous materials sites. The Contractor will be responsible for site safety at all times during this project. The Contractor must maintain documentation that their on-site workers in the exclusion zone ("hot" zone) meet the health and safety requirements of OSHA and L&I. Inspection required by BCD for "secure "site; contact Judy Surber @ 379-5084 for inspection TRAFFIC CONTROL Traffic control plans are required per the city's Engineering Design Standards. A traffic control plan shall be submitted to the Director of Public Works for review and approval. Trucks shall be directed to use collector and arterial streets wherever feasible. Use of local access streets through residential neighborhoods shall be minimized Where truck routes traverse school zones, the report shall specify measures to ensure the safety of school children. DEMOLITION During demolition, the contractor will conduct a survey of all buildings for asbestos-containing building materials and lead- based paint, using trained and certified personnel. If asbestos- containing materials are discovered, contractor will stop work and follow all state abatement and demolition procedures. Materials from demolition are to be removed from the site via a barge to minimize traj~c impacts on Water Street. Demolition materials shall be disposed of on upland areas that meet all qualifcations as set forth by state and local law. Prior to the first day of piling removal the anolicant/contractor shall notify the BCD DeDartment• contact Judv Surber (a7 379- 5084 J Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 5 L. W REQUIRED INSPECTIONS APPROVED/DATE Permit NBLDOJ-207 FIRE SUPPRESSION Applicant/contractor shall coordinate with Fire Department for compliance with NFPA 13 prior to driving of any piles PILES -special. inspection required Trestle Pile Caps Dock Pile Caps Abutment Pile Caps Embedment Resistance Batter Piles Pile Splices/Welds in the event of tnsufjicient bearing depth CONCRETE -special inspection required Concrete Backwall Pipe Sleeves Reinforcement- 60 grade steel, no splices TRESTLE Trestle Grating Grating support @ 3' 1'/z" x '/<" heavy duty welded rectangular steel bar grating Trestle Handrail DOCK Framing Ald DFglu-lam members shall be pressure treated; 8 3/4 " x 21 3/4 " glu-lam stringers required far trestle and dock; install with natural (if any) camber up 3 "x and 4 "x members speed @ #1 Timber Deck- positive connections Corner Framing Dock Cleats Dock Handrails & Extensions TS Diagonals Reflective Panels RAMP -welding performed by certified structural welders Edge Protection Handrails & Extensions Thresholds Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 5 REQUIRED INSPF,('.TiIINS APPI?(1v~nm~T~ Permit #BIS703-207 - _ -- _ _ GANGWAY -all welding and installation ofA325 bolts shall a,r airs a av be performed by certified structural welders; gangway and kayak platform floors shall be Duradek (manufacturer's installation instructions shall be on-site) Positive Connections Support Arm, Guy Wire Anchor Pad Eye Details Transition Ramp Connection Access Ladder Mast Connection - (16) I %." A325 bolts FLOAT Main Float and Finger Float Walers Stiffeners Positive Connections Float Cleats Main Float Pile Hoop Details Fender Details @ floating dock Fender Details @ main pile supported dock FINAL Fire Department Approval Public Works Approval Planning Department Approval -contact Judy Surber @ 379- 5084 Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11 3 85-22 94. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Snits shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 5 Permit #BLD03-207 • 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required. Public Works aonroval must be received nrior to scheduling the Building Deaartment's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THI5 PERNIIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 5 of 5