HomeMy WebLinkAboutBLD03-193Waterman & Katz Building
181 Quincy Street Suite 301
Port Townsend, WA 98368
Phone (360) 344-3057 Fax (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-193 Issued: 09/12/03 Parcel Number: 948 100 016
Job Address: 2137 Washington Street Zoning: C-II Type: V-N Occupancy: R-1
Total Occupant Load: No Change Nature of Work: Repair decks and replace railings
Owner: Edgewater Condominium Association Contractor: T & M Construction - TMCONCIOISMK
(385-3806)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
i2 Ti llTT712F71 TNCPF.f TT(1NC
A PPR [1VF 1)!n A TF
DEMOLITION
All construction debris to be deposited in Jefferson
County Landfill or other location in accordance with all
local, state and federal laws.
FOOTINGS
.S~ettmcles~
Deck Pier Footings - 24" x 24" x 12" (12)
with 30" x 30" x 12" in 3 places:
r;~ t
~~~ _T- ;~ t ~ ~ ~
Near skylight --
Proximate to end of cantilevered triple joist
Under corner of "L"
Reinforcement - (3) t/z" rebar each way
FLOOR FRAMING/DECK
All framing members to be pressure treated or wood of
natural resistance to decay
Posts: New 4 x 6 posts at ground level
New 4 x 4 post to inside corner 2nd Floor
Beams
Joists (2" x 8" @ 12" o.c. or 2" x 10" 16" o.c.)
Relevel 2°d and 3`d Floor Walkway
New 4 x 8 header w/ 4 x 10 corner post
Replace 2 x 8 east side fascia
Replace soffit
Positive Connection
Post-to-Pier: Simpson Post Base
Post-to-Beam
Treated Wood to Concrete
Lag Bolts @ ledger -''/z" galvanized thru bolts w/nuts &
washers or lag bolts, staggered 2" from top & bottom
~ Blocking
Handrails - 2nd and 3rd Floors
Ca1148 hours before you dig utility line locates: 1-800-424-5555
Page 1 of 2
Permit # BLD03-193
FINAL
Building Numbers posted (minimum 5")
Guardrails
Handrails
Landings
Smoke Detectors throughout existing construction per 1997
UBC; one in each sleeping room with minimum one on
each floor.
Deck -Final
GENERAL CONDITIONS
1. Contractors wording on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting; etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection reporfcorrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig utility line locates: 1-800-424-5555
Page 2 of 2