HomeMy WebLinkAboutBLD03-189
Watem~an & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
CITY OF PORT TOWNSEND
Permit Number: BLD03-189 Issued: 09/03/03 Parcel Number: 968 500 106
Job Address: 4224 Hill Street Zoning: R-II Type: V-N Occupancy: R-1
Total Occupant Load: 3 each auartment Nature of Work: Construct Four-nlex auartment
Owners: Helen Arnold Contractor: Camubell Construction - CAMPBC111LR
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
.NOTE: All elements of engineering require inspection prior to cover
RF.nTTTRFT) TNCPFf TT(lNC
A pA1?l1VTil /il A TLS
- - - -
TEMP EROSION & SEDIMENT CONTROL ~ ~.
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
Footings ' ~ ~ -''~~~~~
~
~'
~ ~ ~
Forms f
1
Reinforcement
.-
__.~____ --T ~
"~
~
-.___-
~ - - _ - -- ---
Inte on r ooh t g
~,,, ~~.-
_-_
_____.a._.~__.~_____._._.. _ - _ ..~... __.__
Porch7IIec c hers ~--- ~
~ t p 6, d,__~___.--~
--~ - '~
LIFER ~,~'` -' ,(,,
u 1 ~~ ~k
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pemrit # BLD03-189
REnTTiRF,n rNCPF.f~~rTnlvc ~ uu~r,«rm ,. mz•
-- - ---- <11
FOUNDATION 1 1~V • JJL/LAl1J
Stem Wall ~ ~ l~ql~
Forms l C
Reinforcement
Anchor Bolts & BP washers
ents -10 required at each unit
Crawl Access
FLOOR FRAMING
Joists -engineered BCI plan shall be on-site at time of
inspection
Blocking
~ (~,/ ~ 3
Positive Connections (((
Treated Wood to Concrete
Anchor Bolts & Washers
Post to Foundation Wall Connection
Knee wall between units for draft stop
PLUMBING:
Rough-In ~-V-T & Clean outs)
Water Supply
Water Hammer Arrester @ clothes & dishwashers
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
R-10 under
Seismic Restraint -strap tank @ 1/3 points
18" A. F. F.
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Whole House Fan @ Bath
All penetrations at 1 hour separation between units to be in 1
Hour shafts. Inspect prior to covering
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
Call 48 hours before you dig for utility line locates
1-800.424-5555
i
Page 2 of 4
m_.,....... ...
_.._..-
...~._~.. _„M......
u~nl,~~~RED INSPECTIONS __
,FRAivitl~ u
Wads -one hour wall separation foundation to roof deck
between DU
Doors -All room entry doors 32"net
Draft stops in with walls separating units
Ceilings
Roof -Engineered truss plan to be on site at inspection
Blocking
Truss Positive Connections
Roof Venting - eave and gable vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better for unlimited glazing
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (window ports)
Doors U-Factor - .20 or better/Rated doors @ garage/house
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION ,,:= `~
Floor (R-30) ~.-~`'
-_ --
C~~ling (R-38 )
apor Barrier: paint
6 mil black poly
DRY WALL NAILING
One- hour between dwelling units at floor ceiling
assemblies and storage
Interior braced wall panels as noted
Walls
Ceiling
Garage/House Occupancy Separation ;4
PRO VED/~
..,
~ ,,
.
'~
FINAL
Public Works Sign-Off
House Numbers - 5" minimum
Stairs and rails
Ramp entry at ground floor units per WAC 51-30
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
moke Detectors -
~~„~l - Rnilrlinu
Permit l1 BLD03-189
TE
f ~; -
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Pemtit # BLD03-189 ~
GENE T, C'n1y1~ITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required Public Works auuroval must be received prior to
scheduling the Building Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call far at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
14. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4