Loading...
HomeMy WebLinkAboutBLD03-185Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 • • • CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-185 Issued: 05/28/04 Parcel Number: 966 300 301 Job Address: 3145 Howard Street Zoning: R-I Type: V-N Nature of Work: Convert Existing Barn to One-Bedroom Home Owners: Robert L. Hansen Contractor: Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE Occupancy: R-3 SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 DL'n7TTUT71 TNCpTi !'"i`T(1NC APPR(lVFll/nATF ~~. ., TEMP EROSION & SEDIMENT CONTROL Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Existing FOUNDATION Existing slab on grade R- 10 required around perimeter PLUMBING Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrestor @ clothes & dishwasher Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater Seismic Restraint -strap tank @ 1/3 points Pressure relief valve drain to exterior, terminate 6" - 24" above ground R-10 under if electric Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 Pemtit # BLD03-185 r: v~n7Tr72Ti n TNCPFf T><(1NC APPROVED/DATE 1\l'J V 11WL i ~ V.a it MECHANICAL Whole house fan -Bath Gas supply LPG Stove -provide specs on-site Source Specific Fans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) FRAMING Walls- per architectural design specifications Holddowns-per architectural design Floor Blocking Posts, Beams and Headers Rafter/ Truss Positive Connections Roof Venting - eave and ridge vents Windows -safety glazing Windows Ufactor - .40 or better for unlimited glazing NFRC window sticker must be on windows & doors at inspection time Fresh Air Intake -Window ports Doors U-Factor - .20 or better/Rated doors @ house Air Seal Fire Blocking Weather Resistive Barrier INSULATION Floor (R-10 ) Walls (R-21 ) Ceiling (R-38) (R-30 @ vaulted), Baffles Vapor Barrier: poly plastic @ walls (4 mil minimum) FINAL Public Works Sign-Off House Numbers - 5" minimum Mechanical/Heating LPG Stove manufacturers instructions onsite Insulation Certificate Smoke Detectors Final -Building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 Pemtit # BLD03-1 SS • GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to • scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Ca1148 hours before you dig for utili line locates t 1-800-424-5555 Page 3 of 3 PORT Tp ~~ ~' CITY OF PORT TOWNSEND ~~ yit~ fi; DEVELOPMENT SERVICES DEPARTMENT '' ' ~ INSPECTION REPORT ~,~w PERMIT NUMBER: `~ ~Y~ ~ ~ ~ ~ ~~ SITE ADDRESS: c`7 ~ '9ys ~ d ~ Q,1~ CONTRACTOR: ~~~ ~~ DATE OF INSPECTION: WORKSITE OR CELL PHONE #: ~~ ~irj~ I TYPE OF INSPECTION REQUESTED: ~ IS ~1 ~~, rn~ p~ ~n~~ .~ For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. ^ APPROVED ^ APPROVED WITH CORRECTIONS ^ NOT APPROVED NOTED BELOW CALL FOR RE-INSPECTION BEFORE PROCEEDING ._ ~ - ~ ~ ~: `\ - -~ ' Approved plans and permit card must be on-site and available at time of inspection. A re-inspection fee may be assessed if work is not ready for inspection. --- _ ~ Inspector ;~ ~_ Date Acknowledged Date