HomeMy WebLinkAboutBLD03-185Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
•
•
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-185 Issued: 05/28/04 Parcel Number: 966 300 301
Job Address: 3145 Howard Street Zoning: R-I Type: V-N
Nature of Work: Convert Existing Barn to One-Bedroom Home
Owners: Robert L. Hansen Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
Occupancy: R-3
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
DL'n7TTUT71 TNCpTi !'"i`T(1NC
APPR(lVFll/nATF
~~. .,
TEMP EROSION & SEDIMENT CONTROL
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving the site
FOOTINGS
Existing
FOUNDATION
Existing slab on grade
R- 10 required around perimeter
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestor @ clothes & dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint -strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
R-10 under if electric
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Pemtit # BLD03-185
r:
v~n7Tr72Ti n TNCPFf T><(1NC APPROVED/DATE
1\l'J V 11WL i ~ V.a it
MECHANICAL
Whole house fan -Bath
Gas supply
LPG Stove -provide specs on-site
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
FRAMING
Walls- per architectural design specifications
Holddowns-per architectural design
Floor
Blocking
Posts, Beams and Headers
Rafter/ Truss Positive Connections
Roof Venting - eave and ridge vents
Windows -safety glazing
Windows Ufactor - .40 or better for unlimited glazing
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake -Window ports
Doors U-Factor - .20 or better/Rated doors @ house
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-10 )
Walls (R-21 )
Ceiling (R-38) (R-30 @ vaulted), Baffles
Vapor Barrier: poly plastic @ walls (4 mil minimum)
FINAL
Public Works Sign-Off
House Numbers - 5" minimum
Mechanical/Heating
LPG Stove manufacturers instructions onsite
Insulation Certificate
Smoke Detectors
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Pemtit # BLD03-1 SS
• GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
• scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
• Ca1148 hours before you dig for utili line locates
t
1-800-424-5555
Page 3 of 3
PORT Tp
~~ ~' CITY OF PORT TOWNSEND
~~ yit~
fi; DEVELOPMENT SERVICES DEPARTMENT
'' ' ~ INSPECTION REPORT
~,~w
PERMIT NUMBER: `~ ~Y~ ~ ~ ~ ~ ~~
SITE ADDRESS: c`7 ~ '9ys ~ d ~ Q,1~
CONTRACTOR: ~~~ ~~
DATE OF INSPECTION:
WORKSITE OR CELL PHONE #: ~~ ~irj~ I
TYPE OF INSPECTION REQUESTED: ~ IS
~1 ~~, rn~ p~ ~n~~ .~
For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want
the inspection. For Monday inspections, call by 3:00 PM Friday.
^ APPROVED ^ APPROVED WITH CORRECTIONS ^ NOT APPROVED
NOTED BELOW CALL FOR RE-INSPECTION
BEFORE PROCEEDING
._ ~
- ~ ~ ~:
`\ - -~ '
Approved plans and permit card must be on-site and available at time of inspection. A re-inspection
fee may be assessed if work is not ready for inspection.
--- _ ~
Inspector ;~ ~_ Date
Acknowledged Date