Loading...
HomeMy WebLinkAboutBLD03-184Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360) 379-3208 Fax: (360) 379-6923 PORT TOWNSEND Permit Number: BLD03-184 Issued: 10/06/03 Parcel Number: 984 602 202 Job Address: 1408 Clallam Street Zoning: R-II Type: V-N Total Occupant Load: 10/2 Occupancy: R-3 /U-1 Nature of Work: Construct Single family residence w/ attached (breezewavl ~ara~e Owner: Ned Crosbv & Pat Benn Contractor: Wallvworks - WALLLEL979C8 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 ~~: Special Inspection required for field welding per engineered plans and UBC Section 1701. S. Special Inspector shall be a Washington licensed engineer or ICBO ce3rtified inspector. ICBO certified ~nspector to either be listed in the current edition of WABO Agency and Inspector Register or present __ redentials to the Building Department rior to performing inspections. Required Special Inspection Reports shall indicate compliance with the plans and specifications and shall be copied to the Building Department in a timely manner. Permit Holder or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by required special inspections. TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 and SDP03-043 Erosion control measures shall be installed on-site Drive Off Mat to restrict sediment from leaving the site GROUNDWORK PLUMBING .Pressure Test Pipe Joints Exposed Pipe Bedding Trap Seal Protection (applies to floor drains) Propane Drain (if applicable) Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 6 IN FOOTINGS Setbacks Footings Forms Interior F n-~~ Deck Column Footings Garage Footing Stair Footings Solarium Sill /~,. LIFER p~! ~,l IS ~ (~~ lp 3 SLAB Thickened Slab Footings R-10 rigid insulation Pe~mit# &.LD03-184 S APPROVED/DATE C ~I ~]'L- A~'T- tt~ cRs'T ~ lbl ~~~3 . /J ~~~~~ (i' Retaining Wall Footing Elevated Garage Slab -refer to detail C, sheet S Reinforcement Portico Slab FOUNDATION/RASTRA WALLS - Rastra construction performed only by contractors certified by Rastra of America Reinforcement -grade, size and spacing varies per engineering e. Grout L1 ;~" ~ ~t b ~' `-' ~2 ,- ~'~ `®~ % ~, ~ ~ ~(.~' P d'Jl / Ledgers/Lintels ''' ~' ~ f Positive Connections Waterproofing/Damproofing~ FLOOR FRAMING NOTE.• Engineered BCI joist plan shall be on-site Joists Blocking l ~ ~ Ledgers ~' Treated Wood to Concrete /~ ~ Positive Connections -engineered straps, blocking, nailing Anchor Bolts and Washers -size & spacing varies per / engineering • Radiant Heat Tubing Ca1148 hours before you dig for utility line locates 1-8Q0-424-5555 Page 2 of 6 ,. Permit # BLD03-184 • REQUIRED IN~PF(''TTnNC s npun~r~nm ~ m~ --- -- - PLUMBING: ~v . i.Liycaii Rough-In (D-V-T & Clean outs) Water Supply Gas Supply Water Hammer Arrestor @ clothes and dishwasher Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve -water pressure to be < 80 psi Water Heater ; Seismic Restraint - 2 places Pressure relief valve drain to exterior, terminate 6" - 24" above ground J~ MECHANICAL -appliance installation instructions shall be ":~; on-site at time of inspection LPG Stove ~' Boiler - HRV '' 6 inch minimum smooth duct Balancing dampers on inlet (fresh air supply) and stale air ~` exhaust ducts 8 inch minimum terminal element ~° Flow grids installed on both supply and return ducts for balancing ,f Source Specific Fans 1 j Environmental Air Exhaust ducting (w/ backdraft ,' dampers), insulation (R-4) and terminus (located 3' from opening) `,< Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 6 Permit # BLD03-184 REOTTTRF.n TN~PF.(''TTON~ APPRnvF.11mATT FRAMING: - - - - - - - - Walls/Floor Beams Treated Wood to Concrete , Blocking Engineered Posts, Beams & Headers Drop Ceiling Roof -engineered truss plan to be on-site at time of inspection; loads to include file roof Truss Positive Connections -engineered hangers, anchors, seats ' . ' Roof Venting -ridge & soffit a ~ Windows -escape Windows -safety glazing Windows Ufactor - .40 or better for unlimited glazing NFRC window sticker must be on windows & ~ doors at inspection time , Solid door U-factor - .20 or better NFRC window sticker must be on windows and doors at inspection time Fresh Air Intake- HRV Air Seal , Fire Blocking Weather Resistive Barrier Weep screeds Solarium/Rastra Kneewall -detail 23, Sheet S4 of plans; see also last two sheets of construction drawing plan set INSULATION S1ab(R-10) Floor (R-30 over basement) jam, Walls (R-22 Rastra) Ceiling (R-38; R-30 vault) ~ ll.,// Baffles /~ Vapor Barrier: paint ` ~ / DRY WALL NAILING Walls Ceiling Enclosed Usable Space under Stairs <- Underside of Breezeway Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 6 REQUIRED INSPECTIONS FINAL LPG Public Works Sign-Off House Numbers - 5" minimum Plumbing Mechanical Fresh Air Certification for Balancing of HRV System Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Stairs; Handrails, Guardrails, Landings Final -Building APPROVED/DATE GENERAL CONDITIONS Permit # BLD03-184 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 5 of 6 ,~ - Permit H BLD03-184 8. All building permits expire if no progress has been made within six months, or if no inspections are done • by the Building Department within one year. Calt for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval rior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • i Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 6 of 6 u • °~Q°p7T°~,~s~ CITY OF PORT TOWNSEND PUBLIC WORKS & y U - ~ DEVELOPMENT SERVICES DEPARTMENT ~°p WASH~~ 9T - ~ ~~ INSPECTION REPORT PERMIT NUMBER: ~~ l-- ~ 1 ~ ~'` Address Contractor Owner Date of Inspection Worksite or Cell Phone# ^ Erosion/Sedimentation ^ Setbacks/Footings/LIFER ^ Foundation Walls ^ Slab Interior Footing/Insulation ^ Groundwork/Plumbing Test ^ Underfloor Framing a :~/ 2 ~-/o~.- ^ Plumbing/Top Out ^ Drywall/Fire Wall ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance ^ Propane Tank/Line ^ Manufactured Home Set-up ^ Mechanical ^ Public Works ^ Framing ^ Other/Consultation ^ Insulation ^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail,FINAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED BYFL~ING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION ~d°APPROVAL ^ CORRECTION REQUIRED b~ ~) ^ APPROVE WITH CORREI~TIONj ^ NEED APPR V,/E~ ~D~ ~P~,LANS & PERMIT ON SITE C.X G~ ~~ , _ ~ L, 1 ~ ~ S~p'Y1 ~1r' C "I `" hl~ ~ ~ ~'L-~It~"' -6. "c%~ .... - ~ ~_._._. -- 1. ~ r ~ t- ~ Cam, / wl ~- ~ ~ ~ ~_ C~ ,~r~C,,:~ i ~-~ ~, ~ L (~- C (~~ I~. CZ ~ t .~:~. ~ .~ Uri ;~ • Approved pl,~ns Inspector permit ca be on-site and available at time of inspection. Date ~ <~'' ! ~~'