HomeMy WebLinkAboutBLD03-179`""'-'` ^ ' Waterman & Katz Building
181 Quincy Street, Suite 201
Port Townsend, WA 98368
Phone: 360-379-5083 Fax 360-385-4290
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11379-4450 for Inspection
Permit Number: BLD03-179 Issued: 09/03/03 Parcel Number: 984-904-301
Job Address: 1650 Cherry St. Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: 2 Nature of Work: Single-family Dwelling
Owner: Vernon Garrison Contractor: Same as Owner
GENERAL CONDITIONS APPLY: See. last cage
SEPARATE PERMITS REOUHtED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF,(1TTTRF.T) TNCPF,(rTTnNC
s nnu nv~n m ~ rr~
TEMP EROSION & SEDIMENT CONTROL See
General Condition #2 & attached Erosion & Sediment
Control Practices (MIP03-097)
Silt Fencing
Graveled construction entrance required to prevent
dirt and sediment from leaving the site
Inspection required prior to construction.
GROUNDWORK PLUMBING ,t Qc~L` ~~ ..
~
~
Pressure Test ' ~
- ` >``~
~> ~~
Pipe Joints Exposed ~ ~ ~
~
Pipe Bedding /
~
,
--
-
ropane ram
_.._._
__ ______ ~_ __---
MONOLITHIC SLAB
Setbacks
Footings
~~
~~~~ ~ .~ ~~~~~~
Reinforcement -
Interior Thickened Footings
Insulation - erimeter with R-10 under entire slab .__ ~p
Hydronic Tubing
CALL 48 hours before you dig for Utility line locates
1-800 424 5555
Page 1 of 4
Building Permit #03-179
REQUIRED IN~PF.f'TT(1NC
~ DDDIIVL~TT ,- mr~
- - -- - - -
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestor @ clothes and dishwasher
Gas Supply
Hose Bibbs - backflow protection required
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
Freeze protect all under-floor water pipe & DWV C11 1 l~V V L' L/LL'111~i
~
r,~ ~
"~/
1
MECHANICAL
LPG Boiler/water heater
Hydronic in-floor heating ,~
`~
Whole house ventilation ~
Whole house fan in F-1 bath
Window ports
Source Specific Exhaust Fans @ F-2 bathroom (SOcfm), ~
kitchen (100 cfm)
Environmental air exhaust ducting (with backdraft ~ /~
~
dampers), insulation (R-4) and terminus (3' from
Y
~
openings into building)
FRAMING
~r~ ~ ~
'
Floor Joists
~~ ~~
~ !~ `~' ~~~t~ ~ ~%'!~-~c ~ ~'~ - ~
._ ~ ~~_,1.~~ ~ <~ t-c ~ ~ C.~~ "~'~Q
Engineered Straps
e ger onneclons
Hangers
DF#1 Posts ~ ~
Premier Structural Wall Panels (manufacturer's specs on-site) ~
Roof Rafters (panel specs on-site)
Attic venting - NA !~~
Posts, beams and headers - DF #I header @ SGD
Windows -escape J
Windows -safety glazing. .`
Window & Glass Door U-factor - .40 or better
NFRC sticker must be on windows at time of inspection
Solid Doors - .20 or better l
Air Seal
Fireblocking
Weather Resistive Barrier
r
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
,' f ti
R F.(lT TTR F.T) TNCpF rTrnl~rc
•
•
Building Permit #03-179
• TTT !\~7TT /tom
- -- -- --
INSULATION
'Walls (Premier Panel) i ..~
Ceiling (Premier Panel) ~ ; ~ ~ ~ ~~ ~ ~~'
Baffles - NA -~' ~ ~~-
Vapor Barrier - (Paint) ni 11~V V L' L/LE'~1L~
~
DRYWALL NAILING - ~ ;
Walls '
Ceiling
Enclosed Usable Space under Stairs ~ ~ ~'~
FINAL
Public Works Sign-off
LPG
House Numbers - S"numbers minimum
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Smoke Detectors
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractox's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11379-4450. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
Call 48 hours bef
ore you dig for utility lme locates
1-800-424-5555
Page 3 of 4
:~ Jr . ~
Building Permit #03-179
6. The Jefferson County Building Department is unable to pass final inspection on your
project until Public Works requirements have been completed and inspected. For Public
Works inspection call 379-5083. A minimum of twenty-four hours notice is required
Public Works approval must be received prior to scheduling the Building Department's
final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval riot to making changes in the field. Contact the
Deputy City Clerk at 379-5083 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
a
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4