HomeMy WebLinkAboutBLD03-166•
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone:360-379-5086 Fas360-385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-166 Issued: 09/02/03 Parcel Number: 948 330 604
Job Address: 114 Grant Street Zoning: R-II Type: V-N Occupancy: RR=3
Total Occupant Load: N/C Nature of Work: Add second storv attic & dormer to residence;
replace several windows and doors on first floor
Owner: David Kaldahl Contractor: Owner
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF,nTTTRF,T) TN~PF.(''TInNC
e ppunv~nm s rr~
DEMOLITION -see MIS03-027 for chimney demo
Materials from demolition shall be taken to the Jefferson
County Landfill or other approved off-site location
meeting all state and local codes
FOOTINGS -per design ~ ,~~-
22" x 22" footings ~_~ , +:- ~"~~~~^ j
2' x 2' footings
27" x 27" footings at front porch
Reinforcement -_.~.~#4 bars each way __ - ------- --------- -_._.__~._,,,_____
__.___-
Simpson CBSQ46 Column Base
FOUNDATION
Engineered Holddowns - 5/8" threaded rod epoxied as , ~~ ~. ~ f ~ 1 ,~.
~~
~
?
~/~ ~
anchor for PHDS holddown !
~ ;
f
Anchor Bolts per shear wall schedule
FLOOR FRAMING
Ledger Nailing
Joists
Hangers
Sleepers
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 3
~"
Building Permit #BLD03-166
REQUIRED INSPF.CTI(()N~
A pUi?l1~7L`ilm A mL~
NOTE: Architect shall be on-site during construction to a_v l/L/ LL I 1 L'
olL ~ ,R~~J14~S ~
inspect existing braced wall panels for compliance p~ c~ ~,, la..~
`T
FRAMING -shear wall nailing requires inspection prior
to cover
Walls
Shear walls
Shear Wall Panel Blocking
CeilinglRoof -Engineered BCI joist plan on-site and
available to the Inspector at inspection time
Blocking
Ridge Straps
Attic venting -soffit & ridge
Posts, beams and headers -per design; roof plate beams
are DF#I
Windows -escape (for future use)
Windows -safety glazing
Window and Glass Door U-factor - .40 or better
Door U-factor - .20 or better for solid
NFRC sticker must be on windows, doors & skylights at
time of inspection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-21)
Ceiling (R-30, vault)
Baffles
Vapor Barrier -paint
6 mil black poly in crawl space
DRYWALL NAILING
Walls
Ceiling
FINAL
House Numbers - 5" numbers
Insulation Certificate (if applicable)
Vapor Barrier Paint Certificate (if applicable)
Smoke Detectors
Stairs, Decks & Landings
Final -building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Building Permit #BLD03-166
GENERAL CONDITIONS
• 1. Contractors working on this project are required to have a Labor & Industri
es
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is reauired. Public Works approval
must be received prior to schedul><ng the Building Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
•
•
~ poor raw
~,~ ~~, CITY OF PORT TOWNSEND
~ ~ DEVELOPMENT SERVICES DEPARTMENT
~~'` ' ~~ ~ , INSPECTION REPORT
~~'~ For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want
the inspection. For Monday inspections, call by 3:00 PM Friday.
DATE OF INSPECTION: ~ ~ PERMIT NUMBER: ~ ~;~Q~~ °' ~~
SITE ADDRESS:
PROJECT NAME: I CONTRACTOR:
CONTACT PERSON: PHONE: ~ ' (~
TYPE OF INSPECTION:
n ~h '~ ,\
_ _ _ ._..
_.
~. ,
,-'
^ APPROVED
^ APPROVED WITH
CORRECTIONS
Ok to proceed. Corrections will be
checked at next inspection
,.
Inspector "'~~, ~ ~- - ' ~ - Date
^ NOT APPROVED
Call for re-inspection before
procee ing.
~' ' ~~
Approved plans and permit card must be on-site and available at time of inspection. A re-inspection fee may