Loading...
HomeMy WebLinkAboutBLD03-164 Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 • CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection CITY OF PORT TOWNSEND Permit Number: BLD03-164 Issued: 09/25/03 Parcel Number: Treehouse PUD. Lot 2/3. Unit 8 Job Address: 1504 W Street Zoning: Treehouse PUD Type: V-N Occupancy: R-3/IT-1 Total Occupant Load: 3/1 Nature of Work: Construct single-family residence with attached garage. Owners: Madrona Village LLC Contractor: QED Builders LLC - OEDBUI*0431D1 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Any work with equipment within the 10' buffer adjacent to San Juan Estates requires prior written approval from BCD Director. RF,nTTTRFT) TN~PF(^'TT(lN~ APPR(IVF.iI/iIATF. • TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks __ _ Footings .._ ._ _.~_.. __ __- _.. .. - - ~ ~ c;`P~~r ~C~ __ f ~ $' Interior ootmgs ~ __ _.. ~ ; ~ ~ ; ~ t "5 l " - , ~° _ ._~ . __A_.___._.__._._~___ orms Reinforcemer __ . _.. _ LIFER Porch/Deck Piers GROUNDWORK PLUMBING Pressure Test Pipe Joints Exposed Pipe Bedding Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 '~`. Permit # BLDQ3-164 REQUIRED INSPECTTnN~ sPPl2nVrnm ~ m~ FOUNDATION ~. ,~,~~~~ 3 ~ )d tl Stem Wall . Forms ~ Reinforcement ( `~~ Anchar Balts - Holdowns -per en ineer design 0 ~^- SLAB Interior Footings ~ U .~~ ~? Anchor Bolts ,q~' R ~ " ~~ " einforcement - 6x6/1 Ox10 wwf ~ ~ A ~ ~ ~~ ~ U PLUMBING: Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrester @ clothes & dishwashers Hase Bibs (backflaw protection required} Pipe Insulation {R-3) Pressure Reduction Valve {water pressure is > 80 psi) Water Heater ' R-10 under if electric 1 Seismic Restraint -strap tank @ 1I3 points Pressure relief valve drain to exterior, terminate ~' 6" - 24" above ground . MECHANICAL Whale House Fan @ main bathroom -Max. 75 CFM Kitchen/BathlLaundryFsns Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Pemilt # BLD03-164 REQUIRED INSPE(rTIONS APPRnVEn/1lATE • FRAMING Walls ~ , ~ ;~ ~'" ~ 4 .Shear Walls -per engineer design ~ ~. _ ~, . ___ _ _ Ceilings-_- ._. __ __- _ _ _~_._ _ __ ___ _~_--- _ T _ - _ __.-..__._------ ._ . Posts, Beams & Headers Roof Ridge Beam Blocking Rafter Positive Connection - H1 Roof Venting - eave and ridge vents Windows -escape Windows -safety glazing Windows Ufactor - .40 or better NFRC window sticker must be on windows & doors at inspection time Fresh Air Intake (Window Ports) Doors U-Factor - .20 or better Air Seal Fire Blocking Weather Resistive Barrier INSULATION Floor (R-30 ) Walls (R-21 ) Ceiling (R-30vault/R-38 attic ) Vapor Barrier: paint for walls and ceiling Baffles DRY WALL NAILING Walls Ceiling Enclosed Usable Space under Stairs Garage/House separation FINAL Public Works Sign-Off Parking -1 space required House Numbers - 5" minimum Plumbing Mechanical/Heating Vapor Barrier Paint Certificate Insulation Certificate Smoke Detectors Final -Building • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Permit # BLD03-164 ENERAT CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries _contractor's reeistration number and a Citv business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is reauired Public Wo_r_ks anuroval must be received prior to scheduline the Buildine Deaartment's final inspection 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Bu' g Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval rior to making changes in the field. Contact the Building Department (379- 3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 °~PpR7T°`~~s~ CITY OF PORT TOWNSEND PUBLIC WORKS 2 U - ~ BUILDING AND COMMUNITY DEVELOPMENT N~ ~;; 2 9T - ~" a "~° INSPECTION REPORT • ~°F WASN~a PERMIT NUMBER: ~ L ~C~~ "" co Address I , V ~'1 ~ S t~f'~'_ ~l Contractor (~o~ Owner ~~~!~v:~: ~~.( ~~, Date of Inspection ~~ ~'~ Worksite or Cell Phone# ~ (,~ ~ ~ `1 ~~ 3 ~~~ ~ Q l '" Z ~G ~ ^ Erosion/Sedimentation ^ Plumbing/Top Out ^ Drywall/Fire Wall ^ Setbacks/Footings/LIFER ,~''~ ~$t\Gas Pipe/Pressure Test ^ Gas/Wood Appliance ^ Foundation Walls ^ Propane Tank/Line ^ Manufactured Home Set-up ^ Slab Interior Footing/Insulation ^ Mechanical ^ Public Works ^ Groundwork/Plumbing Test ^ Framing ^ Other/Consultation ^ Underfloor Framing ^ Insulation ^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail FINAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED BY BUILDING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION ^ APPROVAL CORRECTION REQUIRED s- ~~~ ~- ~~1,1; c (, 1~~1~~ , ~,~~C - `dam ~ ~ '1~,- ~i"~~ _. ~ ~ ~- ~_. ~.. .. .. ~ " __.- .. r.. - , -. _ , s ~~ ~ t ~ /' - 1 `F ` A .~~ .., r - _ t ~. i ~ ~' ~~ Approved plans and permit card must be on-site and available at time of inspection. .`."!. f.... ~~ , _ ~ ', Inspector ~- ~`~ _ ___ Date -~ ~' ~`;"