HomeMy WebLinkAboutBLD03-160
C:
•
•
Waterman & Katz Building
181 Quincy Street, Suite 30]
Port Townsend, WA 98368
Phone: (360) 379-3208 Fax: (360) 385-7675
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
CITY OF PORT TOWNSEND
Permit Number: BLD03-160 Issued: 09/09/03 .Parcel Number: 985 204 904
Job Address: 1001 U Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: 6 Nature of Work: Construct single-family residence.
Owners: Michael & Clea Barenburg Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
REOTJTRET) TN~PF.(^'TTnN~
A PPR C1VFil/11 A TF.
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
~ `
FOOTINGS
Setbacks '
Footings -per architectural design
;~
,
Interior Footings
Forms
Reinforcement _ ~
LIFER }
Porch/Deck Piers ~ ''
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts
Retaining Wall -per architectural design
Holdowns
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pemtit # BLD03-160
REQUIRED INSPECTInN~ a ppunvFr~m ~ /rte
GROUNDW ItK ~~ ,
- c''
-
Press T ''C-
Pipe Joints Exposed °~ _..~._._..m
Pipe Bedding
SLAB
Interior Footings
Anchor Bolts
PLUMBING:
-In -V-T & Clean outs) ,~/
u o !~C '~ ' ~ '~~ ~/
Gas Supply
Water Hammer Arrester @ clothes & dishwashers
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
R-10 under if electric
Seismic Restraint -strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
LPG Stove -manufacturer's installation instructions shall
be on-site at time of inspection.
Whole House Fan @ @ upstairs bathroom -Max. 75 CFM
Kitchen/Bath/Lauridry Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
l~h, ~ie~~.-3,3i,c~ ~
l F`~`~at ~acQ f{~-' ~Z~f ZN ~ >~
.~.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
~,
~'
PECTI
FRAMING
Walls
-Shear Walls -per architectural design
Ceilings
Posts, Beams & Headers -per architectural design
Roof
Ridge Beam -per architectural design
Blocking
Rafter Positive Connection - H1
Roof Venting - eave and ridge vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (Wall Ports)
Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-21 )
Ceiling (R-30 vault/R-38 attic )
Vapor Barrier: paint for walls and ceiling
Baffles
DRY WALL NAILING
Walls
Ceiling
Enclosed Usable Space under Stairs
•
FINAL
Public Works Sign-Off
House Numbers - 5" rriinimum
LPG
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final -Building
Perntit # BLD03-160
OVED/DATE
~_ _~
{.
,, ~.
l ..
,~,
(, `
- l
'1
', '~~
r.
S
~`
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Pemrit # BLD03-160
'i
+~,
GENERAL. CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (3'79-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555