HomeMy WebLinkAboutBLD03-155f
•
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: 360-379-5086 Faz 360-385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-155 Issued: 08/08/03 Parcel Number: 965 702 902
Job Address: 1440 Lawrence Street Zoning: R-II Type: V-N Occupancy: R-3/U-1
Total Occupant Load: N/C Nature of Work: Seismic retrofit, demo, bath remodel, re-roof
Owners: Richard Rackowski Contractor: Same as Owner
GENERAL CONDITIONS APPLY: See Last Page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF.if1TTTRF.TI TNCPFf''TrnNc
A DDDllA7L~i1m A mn
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfill or other approved off-site location
meeting all state and local codes
FOUNDATION
Seismic Retrofit with Simpson Foundation Anchors
~.
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestors @ clothes & dishwashers
Hose Bibbs - backflow protection required
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 3
Building Permit #03-155
REQUIRED IN~PF.f'TI[1NC A DDn ~l~ Tr, r m • mT,
-- -- - - -
MECHANICAL r tii r 1~V v L' L/LL's 1 L'
New chimney for oil furnace
Source Specific Exhaust Fan @ bathroom (SOcfm),
(if no existing)
Environmental air exhaust ducting (with backdraft
damper), insulation (R-4) and terminus (3' from
openings into building)
FRAMING
Walls
CeilinglRoof
Attic Venting ;'
Air Seal
Fireblocking
INSULATION
Fill any exposed exterior wall cavities
Baffles at vented roof bays
DRYWALL NAILING
Walls ~
Ceilings ;~
a
FINAL
House Numbers - 5" numbers
Smoke Detectors throughout existing construction: one in
each sleeping room and area leading to each sleeping room
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
i
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Building Permit #03-155
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required Public Works approval
must be received prior to scheduling the Building Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
• inspection per year to keep your building permit active.
9. Revis><ons require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555