Permit Number: BLD03-145 Issued: 09/18/03 Parcel Number: 984-601-505
Job Address: 1720 Monroe Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: 1 Nature of Work: Convert garage to heated storage space.
Owner: Baila Dworsky Contractor: Owner
385-1717
GENERAL CONDITIONS APPLY -SEE BELOW
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,(~TTTRF,TI T~v~PF.r'TTn~vc
A Dpi]!lt TT7l m • mr,
FLOOR FRAMING
2" x 4" sleepers
Blocking @ 10'
Positive Connection
Treated Wood to Concrete
FRAMING:
Walls - 2" x 4" built out to 2" x 6" . .
Roof - 2" x 8" @ 24" o.c. sistered to existing 2" x 4" - - -
Attic Venting - @ 1/1 SD if not existing
Window (French Door) U-factor - .40 or better
NFRC sticker shall be on windows at time of
Inspection
Windows on North side to be removed; Glass Block rated to
1-hour Fire Resistance acceptable in existing openings.
Air Seal ,; ~.:
Solid Door U-factor - .20 or better
Weather Resistive Barrier . ~ _ :~~
Fire Blocking (if applicable) l•
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
RE UIRED INSPECTIONS
Permit # BLD03-145 ~
APPROVED/DATE
INSULATION
~ ~ ~ ~~~
D3
Sy
b (R-10 at Slab Perimeter ) (
xtenor a s -_ ----
~eiling (R-30)
~ ~ ~O ~' ~ C~1./ ~,;. ~ j
a es ~ ~`~. ~~ ,,,T 1 II_ f ;~ j
Vapor Barrier -paint J
l
DRY WALL NAILING
Walls - On North Wa1121ayers 5/8" Type "X" GWB
Ceiling ~~
l
FINAL
House Numbers -check for 5" numbers
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detector -hard-wired with battery back-up
Final -Building
GENF.RAi. CON I ION
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached detaiIs). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required Public Works approval must be received prior to
scheduling the Building Department's final inspection
7. -Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
~'
i
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
,~ 8. All building permits expire if no progress has been made within six months, or if no inspectionstare done
by the Building Department within one year. Call for at least one inspection per year to keep your
`~ building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3