HomeMy WebLinkAboutBLD03-141s • Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection CITY OF PORT TOWNSEND Permit Number: BLD03-141 Issued: 08/12/03 Parcel Number: Treehouse PUD. Lot 4. Unit 21 Job Address: 2312 Ebony Street Zoning: Treehouse PUD Type: V-N Occupancy: R-3/U-1 Total Occupant Load: 4/1 Nature of Work: Construct single-family residence with garage. Owners: Madrona Village LLC Contractor: QED Builders LLC - OEDBUI*0431D1 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Any work with equipment within the 10' buffer adjacent to San Juan Estates requires prior written approval from BCD Director. RFnTTTRFn TN~PF.("TT(1N~ • APPRnVF.I<l/11 A TF. TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 . Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS -~ ~'.r'~t..~L.~rd~c~- ~~~ ~ ®~.~ r,'~ ~ , __ __ Setbacks ---. _ __ _ _____. __~ ._ __ - _=~ Footings Interior Footings 1 r ~ ~- ~ ~,~~_ . _ ~,,~ ~ . !2 Forms . Reinforcement - _ _ ._._ __ _ _ _:___... ___._a____~ ____~~________m __._. . ER _ _. .__ - ._ _-_. _ Porch/Deck Piers r - ~ _ _. _ .... _ _ f r`~ ~ r `~ ~ I r~ ; j GROUNDWORK PLUMBING Pressure Test Pipe Joints Exposed Pipe Bedding Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Pemrit # BLD03-141 REQUIRED INSPECTinN~ A ppunvF.nm s TF - - - - FOUNDATION ~ ~V Y/ Ll 111J J ~ 9 3 D3 ~~k~E Stem Wall Forms Reinforcement Anchor Bolts - -per architects shear wall schedule Holdowns -per architectural design Vents - 4 required SLAB kK„~4--~~ s-t~46 0~ ~ Z o 3 Setbacks Forms Interior Footings Reinforcement - #3 @ 24" o.c. each way @ slab Holdowns -per architectural design FLOOR FRAMING -engineered BCI plan shall be on-site at time of inspection Joists Holdowns -per architectural design Beams & Headers -per architectural design Blocking Shield under Posts Positive Connections Treated Wood to Concrete PLUMBING: Rough-In (D-V-T & Clean outs) Water Supply Gas Supply Water Hammer Arrester @ clothes & dishwashers Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater R-10 under if electric Seismic Restraint =strap tank @ 1I3 points Pressure relief valve drain to exterior, terminate 6" - 24" above ground ,,~ .J ! Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Pemrit # BLD03-141 REQUIRED INSPECTInNS A PPR nvF.nin a TF. M MECHANICAL LPG Stove- manufacturer's installation instructions shall be on-site at time of inspection, Whole House Fan @ @ upstairs bathroom -Max. 75 CFM - Kitchen/Bath/LaundryFans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) FRAMING Walls Shear Walls - er architectural desi n P g __ ~ 5 c ~~ ~ J~~'~ ~a ~ ~ ~, ~ _ Ceilings - ~b ~ ~~ , ~- Posts, Beams & Headers -per architectural design Roof Ridge Beam -per architectural design Blocking Rafter Positive Connection - H1 Roof Venting - eave and ridge vents Windows -escape Windows -safety glazing Windows Ufactor - .40 or better NFRC window sticker must be on windows & doors at inspection time Fresh Air Intake (Window Ports) Doors U-Factor - .20 or better Air Seal Fire Blocking Weather Resistive Barrier INSULATION Floor (R-30) ~ Walls (R-21 ) Ceiling (R-30vault/R-38 attic ) Vapor Barrier: paint for walls and ceiling Baffles DRY WALL NAILING ~' Walls _,...=-'' ~' Ceiling , ~ ~~ ,t Enclosed Usable Space under Stairs iv ~ r' ~-~ , Garage/House Occupancy Separation ~ P_ '/ Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Pemvt # BLD03-141 REQUIRED INSPECTIONS APPROVE FINAL Public Works Sign-Off Parking -1 space required House Numbers - 5" minimum LPG Plumbing Mechanical/Heating Vapor Barrier Paint Certificate Insulation Certificate Smoke Detectors Final -Building GENERAL CONDITIONS ,;., 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (AB~ require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required, Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. •~ Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 I~TSI'l:C'1'It)\~ li.l:l~t)li.'1' NAME ~~ Permit No. ~~ "~l ~~ ~ `VC~Ii > ` °~ n ~" ~~~~~ ~E` ~ ~~ ~" ~~ G~ ~ ~ ~ ~ Cr,' . it C~t l~~ / ' ~~ i ~ L~'/2 ~ ~~ ~~~~~ ~~~~ ~`~ ~x~~~ 1~ ~ ~ '. ~1~~~~~t~ ~ ~~ ~~~~~ ~~~ )O NOT REMOVE THIS TAG Date ~-~~~~~~ By ~.~ CITY OF PORT TOWNSEND, BUILDING & COMMUNITY DEVELOPMENT WATERMAN & KATZ BUILDING, 181 QUINCY ST, SUITE 301, PORT TOWNSEND, WA 98368 (360) 379-3208 YOU ARE HEREBY NOTIFIED THAT NO MORE WORK SHALL BE COVERED UPON THESE PREMISES UNTIL THE ABOVE VIOLATIONS ARE CORRECTED. WHEN CORRECTIONS HAVE BEEN MADE, CALL FOR REINSPECTION AT 385-2294. YOU MAY APPEAL DECISIONS OF THE BUILDING OFFICIAL TO THE BOARD OF APPEALS WITHIN 15 DAYS OF INSPECTION DATE. FOR FURTHER INFORMATION CONTACT BCD AT (360) 379-3208