HomeMy WebLinkAboutBLD03-135Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: 360-379-3208 Fax 360-385-7675
u
n
U
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-135 Issued: 08/06/03 Parcel Number: 989 710 503
Job Address: 928 Franklin Street Zoning: R-II Type: V-N Occupancy: UU=1
Total Occupant Load: 1 Nature of Work: Construct Detached Caruort for Single Family Residence
Owners: William Miller & Karen Knowlton Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
REOUTRED TNSPEC.TTONS
APPROVFn/DATF.
TEMP EROSION & SEDIMENT CONTROL
Silt Fence & Drive Off Mat as needed during construction
to prevent erosion and prohibit tracking of dirt and debris
onto Cityrights-of--way. Okay to use existing driveway as
construction entrance. See General Condition #2
FOOTINGS -Per attached engineering
Setbacks T 10 feet from rear; 5 feet from side property
lines. Measurements shall be from outside of posts.
Eaves may go into setback maximum 2 feet.
Footings
Forms
Reinforcement - (2) #4s each way under post ,
Concrete Pier Footings - (4) 24" x 18" x 4'
Verify post hole dimension prior to pour
Pak Mix Proline or Quikcrete #1101
Verify thickness of punch pad after pour prior to post set
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Building Permit #BLD03-135
RE UIRED INSPECTIONS APPROVED/DATE
FRAMING:
Walls - (8) PT posts
Ceiling/Roof -site built engineered truss plan -Sheet A-6
Bracing
Blocking
Post-to-Truss Positive Connection - (3) each member
Post-to-Beam Connection
FINAL
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's.
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut. down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt
and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP} require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
S. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's fmal inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLAN5.
10. Revisions require review and approval prior to making changes to the approved plans. Contact the
Building Department at 379-3208 prior to making changes to the approved plans.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page Z of 2