HomeMy WebLinkAboutBLD03-130Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
P6oce:360.379-5086 Fax360-385-7675
CITY OF PORT TOWNSEND
Permit Number: BLD03-130 Issued: 07/15/03 Parcel Number: 974101 704
Job Address: 420 Reed Street Zoning: R-II Type: V-N Occupancy: R=3
Total Occupant Load: 2/1 Nature of Work: Construct second story (Craft Room)
over existing garage
Owner: Bob Engle Contractor: Troy Frotiger Homecrafting TROYFHC9870Q
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
D7r l17TT7?Ti Tl TNCPFf TT(1NC
A PPR (1VF.1~/n A TF
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS ~ ~ f.
~
Deck/Stair footings ~
',
~'~ ~~~ : "f -' "'`
~~
PLUMBING
Rough-In (D-V-T & Clean outs) ~
~
Water Supply
Water Hammer Arrestors ,
t/' ~ `
LPG Gas Supply
Hose Bibs - backflow protection required
P pe TnsuTation (R=3)
Pressure Reduction Valve if > 80 psi
Water Heater
R-10 under if electric
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
Building Permit #BLD03-130
RF,nITiRF,n IN~PF("TI(1N~ eppRnvFnmeTF
MECHANICAL
LPG Stove - provide specs on-site
Manufacturer's installation instructions to be on-site
@ time of inspection.
Source Specific Exhaust Fans @ bathrooms (SOcfin),
laundry room, (50 cfin) and kitchen (100 cfin)
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from openings)
Whole hou a fan -Bath
~/
I G
Floor -existing
Walls
Si~earw~
Roof
Rafters
Attic venting -ridge & eave
Posts, beams and headers D1 ~j ~ (~~~
Windows -escape
Windows -safety glazing
Window U-factor - 0.40 or better
Door U-factor - 0.20 or better
NFRC sticker must be on windows, doors &
skylights at time of inspection
Air Seal
Fresh Air Intake -window ports
Fireblocking
Weather Resistive Barrier
Dec & stairs
INSULATION ~~'Io a~ ~ ~ ~
Floor (R-30 )
Walls (R-21 ~ ' ~ G _~ ~,~~ ~,~ d
"
Ceiling (R-38, attic; R-30, vault) ~ ~1 ~ t ~ ~
.-_._,__,__
B ffles
Vapor Barrier -paint
DRYWALL NAILING
Walls
Ceiling ~ ~~,
l pl 3 03
Garage / ADU Occupancy Separation ~ ~
/
Fib
•
s
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
t ~. ~ ~
Building Permit #BLD03-130
UIIZEl)
•
FINAL
Public Works Sign-off
House Numbers - 5" numbers
Plumbing
LPG
Mechanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Stairs, Decks & Landings
Final -building
1'lUN S APPROVED/DATE
E
,r
,
" f,
,~
---i~"
..
° . }
f ..~
` E
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
• 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public-Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
~.
,r ~ .~i
Building Permit #BLD03-130
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
i
Ca1148 hours before yon dig for utility line locates
1-800-424-5555
Page 4 of 4