HomeMy WebLinkAboutBLD03-117- ~ Watem~an & Katz Building 181 Quincy Street, Suite 301 p Port Townsend, WA 98368 'Y Phone: (360)379-3208 Fax: (360)385-7675 +, CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-117 Issued: 7/01/03 Parcel Number: 946 800 101 Job Address: SW Corner of F & Chestnut Streets Zoning: P-I Type: II-N Occupancy: SS=2 Nature of Work: Construct New Pumu Station/En~ine Generator Occupant Load: N/A Owner: City of Port Townsend Public Works Contractor: Stan Palmer Construction Inc. STANPC*202NF GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor and Industries @ 360-417-2702 NOTE: Special Inspection is required for concrete, placement of reinforcing steel, bolts embedded in concrete, and epoxied bolting/rebar per the engineers structural notes, Sheet S-1 of plans. Special Inspector shall be ICBO certified in their specific field and listed in the current edition of WABO Awn y and Inspector Re ig ster or present credentials to the Building Department prior to performing inspections. Required Special Inspection Reports shall indicate compliance with the plans and specifications and shall be copied to the Building Department in a timely manner. Permit Holder or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by required special inspections. **Hours of construction are limited to 7 a.m. - 6 p.m. Monday-Friday** RE UIRED INSPECTIONS • APPROVED/DATE TEMP EROSION & SDM'T CONTROL -,flag (3) existing maple trees to protect from clearing, grading and construction activities Erosion control measures to be installed during construction per the attached plans DEMOLITION Materials from demolition shall be disposed of in areas off-site meeting all requirements of State and local law FOOTINGS Footings Forms ~ ~' ,/ ~~~ r ~ ~ ~~ ~ -" ~ Reinforcement - rade 60 steel ~ 7 -* , 1 I U _~! ~ Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 r ~J' ~ ' ~~ ~'~ ~~~" 1. Pemtit N BLD03-117s REQUIRED INSPECTIONS h'~ ~-/~`~'~appRnvFnmaTF ~ SLAB FOUNDATION - (2) #S trim bars required around all openings, walls and slab Forms Reinforcement -grade 60 steel Floor Drain Trap Seal Protection UFER Anchor Bolts - wetsticking of anchor bolts prohibited FOUNDATION Below Grade Walls © ~ O~~O j Reinforcement rs PLUMBING Rough-In (D-W-V & Clean OutsO Water Supply Pipe Insulation (R-3) Pressure Reduction Valve if pressure > 80 psi Hose Bibbs 1" rBackflow Pr venter t,~r~~~x.tr~ sr'u-tM6-~G aIL -1 3o O"~ MECHANICAL Exhaust and Supply Fans and Terminus Intake and Exhaust Louvers w/ backdraft dampers FRAMING -All welding to be done by certifted Welders; (2) #S trim bars required around all openings, walls and slab Walls Doors - U factor per attached component performance Roof Positive Connections Fireblocking INSULATION Per attached NREC component performance LIGHTING NREC Lighting for interior and exterior per attached NREC compliance form • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Permit # BLD03-] 17 RE UIRED INSPECTIONS APPROVED/DATE LANDSCAPING Per the attached plan; contact John McDonagh @ 379-5085 for inspection FINAL -Restrictive Covenant required prior to final Property Address Posted -minimum 5" numbers Fire Department Approval Electrical Approval (L & I) Barrier Free Access & Design -stairs, ramps, handrails, etc. Final -Plumbing Final -Mechanical Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works aaproval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non- residential project. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 M Permit k BLD03-117 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions from the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. i 1 Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4