Loading...
HomeMy WebLinkAboutBLD03-094Waterman & Katz Building 181 Quincy Street, Suite 30l Port Townsend, WA 98368 Phoce: 360.379-5086 Fax 360-3857675 ., • 1~ CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-094 Job Address: 420 Cass Street Total Occupant Laad: 2 Owner: Nevitt & Carla Pugh Issued: 07/22/03 Parcel Number: 957 308 008 Zoning: R-II Type: V-N Occupancy: R,=3 Nature of Work: Construct Detached ADU Contractor: Greg Pelham - Greenstreet Construction GREENC*981 DR - (385-3147) GENERAL CONDITIONS APPLY: See last page SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 RF.(ITTTRF.TI TNCPF.f TT()NC APPRnVFn/nATF, TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS '''' Setbacks 6F{ Footings Forms _. ._, Reinforcement ~ ' ~~ Interior Footings ., ~' ~ Porch footings ~~ ~:'~ Pier Footings -per design: F _ 24" x 24" x 8" w/(3) #4 Each Way LIFER ~~,~ " ,y"~~ - ;, FOUNDATION Stem Wall ` Forms Reinforcement ~' Anchor Bolts & Washers r Post to Foundation Wall Positive Connection Holdowns -per architectural design ..: ~'~ ~`/r-% ~- '" CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 4 Building Permit #BLD03-094 RFOi7iRFD TNSPFCTTnNS A PPR (1VT.il/D A TF. • FLOOR FRAMING Joists Blocking Positive Connections Treated Wood to Concrete Anchor Bolts & Washers P.T. Posts -per design Post Base Post Cap Beam/Post Connection - HUS410 inside ~°' ~ ~ ~' `~ ~~ ~' PLUMBING Rough-In (D-V-T & Clean outs} Water Supply Water Hammer Arrestors LPG Gas Supply Hose Bibbs - backflow protection required Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground MECHANICAL LPG Furnace -provide specs on-site Manufacturer's installation instructions to be on-site @ time of inspection. Source Specific Exhaust Fans @ bathrooms (SOcfin), laundry room, (50 cfin) and kitchen (100 cfin) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whole house fan -bathroom s Call 48 Lours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Building Permit #BLD03-094 • RF()TTTRFT) TN~PF.C'TinN~ APPROVED/DATE FRAMING :'; ~ ;'~ `_" ,~, ll _ '~ ,, ~1_ 1 ~ ~J ~~' Wa s _ . '' : Shear walls -per architectural ---~ -•T-~------'-----_-e_ ...__~% ___ ___.._.__ S ear aneTSlocking Roof ~--~"~ Attic venting -ridge & eave r~` Engineered Beams ~ Posts, beams and headers ~- ,a Windows -escape Windows -safety glazing Window U-factor - 0.40 or better A' Door U-factor - 0.20 or better _ ~' Skylight U-factor - 0.58 or better ~, NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake -wall ports Fireblocking Weather Resistive Barrier INSULATION Floor (R-30) ~"- ~ Walls (R-21) , - - _ -:r'" ~ / Ceiling (R-30) ~ . Baffles - ~ , ` Vapor Barrier -paint _. `"" '` ~ ~~ DRYWALL NAILING _ _. __, ~ ,, /' ~, ~ ~ ~ /~ Walls ~'w'~i'~'t'` ~,. Ceiling ADU/House Occupancy Separation -1 hour construction FINAL ' Public Works Sign-off House Numbers - 5" numbers Plumbing LPG MechanicaUHeating Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Stairs, Decks & Landings Final -building Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Permit #BLD03-094 , ~ GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call ~' 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility tine locates ~L 1-800-424-5555 Page 4 of 4 " • • Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: 360-379-50$6 Fax 360-3857675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD03-094R-1 Issued: 10/17/03 Parcel Number: 957 308 008 Job Address: 420 Cass Street Zoning: R-II Type: V-N Occupancy: RR=3 Total Occupant Load: Z Nature of Work: Revision #1: Change foundation shape and location of back door for Detached ADU Owner: Nevitt & Carla Pugh Contractor: Greg Pelham - Greenstreet Construction GREENC*981DR - (385-3147) GENERAL CONDITIONS APPLY: See last pale SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 D Ti` !17 TTi? 7+ Tl 7NCpTi !''Tlf (1NQ A PPRnVFnlnATF. See also original inspection record for required inspections and original plans for red-lined corrections FLOOR FRAMING -see also original inspection record Joists -sizing per structural design Engineered Floor to Floor Holdowns PLUMBING -see original inspection record MECHANICAL -see original inspection record FRAMING -see also original inspection record Shear walls -per structural design Posts, beams and headers -per structural design INSULATION -per original inspection record DRYWALL NAILING -per original inspection record FINAL -per original inspection record CALL 48 hours before you dig for Utility tine Locates 1-800-424-5555 Page 1 of 2 Building Permit #BLD03-094R-1 . GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2