Loading...
HomeMy WebLinkAboutBLD03-090Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: 360-379-5086 Fax 360-3857675 • CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD03-~90 Issued: 05/09/03 Parcel Number: 989 712 902 Job Address: 631 Benton Street Zoning: R-II Type: V-N Occupancy: RR=3 Total Occupant Load: 3 Nature of Work: Add second story & deck to residence Owner: Donna Haynes Contractor: Chohrach Construction - CHOHRCC998J0 GENERAL CONDITIONS APPLY: See last ua~e SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 RF.()TITRFT) TN~PF,C'.TTnN~ A PPR (1VFil/Il A TF. TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Deck PLUMBING Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrestors Hose Bibbs - backflow protection required Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater -Existing R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 4 Building Perrnit #BLD03-090 • • U RFnT1TRF,1~ TN~PF("TTnNS APPROVED/DATE MECHANICAL Source Specific Exhaust Fans a7 bathrooms (SOcfin), laundry room, (50 cfin) and kitchen (100 cfm) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whole house fan -bathroom FRAMING -Per architectural drawing Floor -Engineered BCI floor plan on-site and available to the Inspector at inspection time Walls Shear walls Shear Panel Blocking Roof Rafters Joist positive connection Joist venting -gable & eave Fireplace clearance to framing Posts, beams and headers Deck Windows -escape Windows -safety glazing Window U-factor - 0.40 or better Door U-factor - 0.20 or better Skylight U-factor - 0.58 or better NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake -window ports Fireblocking Weather Resistive Barrier INSULATION Floor (R-30 ) Walls (R-21) Ceiling (R-38;-30, vault) Baffles Vapor Barrier -paint 6 mil black poly in crawl space DRYWALL NAILING Walls Ceiling Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Building Pernut #BLD03-090 REQUIRED INSPECTIONS APPROVED/DATE • FINAL Public Works Sign-off House Numbers - 5" numbers Plumbing LPG Mechanical/Heating Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Stairs, Decks & Landings Final -building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be • permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass fmal inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final-inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Permit #BLD03-090 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. S 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4