HomeMy WebLinkAboutBLD03-088Waterman & Katz Building ~ 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Pbone:360-379-5086 Fax 360-385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD03-088 Job Address: 111 Vista B-vd Total Occupant Load: 6/2 Issued: 05/05/03 Parcel Number: 963 700 012 Zoning: R-II Type: V-N Occupancy: RR=3 Nature of Work: Construct Single-family Dwelling with attached garage Owner: Bruce Logan • • Contractor: TI3D GENERAL CONDITIONS APPLY: See last page SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & L~dust,•ies 360-417-2702 1?Ti f17TTl?TiTI TNCPFif TT(1NC ~; PPRf1VF,il/1lATF. TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 ~ r Silt Fence as needed ~' ~` ~ ~ ~ ~> `~' ~~~'~~ `~ Drive OffMat to restrict sediment from leaving the site FOOTINGS Setbacks f `~' f Footings -• ' - -_~f ~~ E Forms Reinforcement Interior Footi -_ _._ _._ _-_ . - _ _ _ _ ___ _____.__. Porch Piers Deck --. - _ _ .. _ _ ___ _ __ _~_ ER " - / ,~ t ~ < ~ ' <, ~ ~ a ~ > ,r CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 5 Liuilding Permit #03-088 REQUIRED INSPECTIONS .4PPRnVF,I)/AATF ,. FOUNDATION Stem Wail Forms Ventilation - 16 vents required Reinforcement Anchor Bolts & Washers Post to Foundation Wall Positive Connection Holdowns ~u ~4r-- a3kc.~.oK. ~ i 03 Cv ~/~~ c~al~ ' SSrS ~~ ~..3e't-"srPc.K~ t a.,( PIJ6~$ FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time Joists Blocking ~ (~ ~ ~ 3-63 Positive Connections Treated Wood to Concrete Anchor Bolts & Washers Rough-In (D-V-T & Clean outs) ~ ~ ~~ ~%~~~' upply Water Hammer estors _____........__ _.._._. ---~-Y- z-~ J Gas Supply 1 -- '~ .,,~ ~ - ~ ' Hose Bibbs -back ow protection required Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Reiief Valve ,drain to exterior, terminate 6" -24" above ground Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 5 Building Permit #03-088 RF.()T1TRF,n TN~PF.CTTON~ APPROVEDlDATE MECHANICAL Electric Heat Pump Manufacturer's installation instructions to be on-site @ time of inspection. Ducts & Duct Insulation -Supply/fresh air ducts in conditioned space: R-4; heating ducts in unconditioned space: R-8 Whole House Ventilation HVAC Integrated Fresh Air . T' Smooth Duct minimum Terminal Element - 8" Clock timer on furnace fan Other than motorized damper requires letter of certification for flow rates. Whole house fan - HVAC Integrated option „ Source Specific Exhaust Fans @ bathrooms (SOcfm), f laundry room, (50 cfm) and kitchen (100 cfm) Environmental air exhaust ducting (with backdraft dampers), insulation (R-4) and terminus (3' from openings into building) ~ ,' FRAMING f, Walls -framing per shear wall designations Interior braced wall panels Shear Panel Blocking 1 Roof -Engineered truss plan to be on site at inspection Truss positive connection Attic venting -ridge & eave Posts, beams and headers Windows -escape , .; ~, Windows -safety glazing ~ Window U-factor - 0.40 or better `' Door U-factor - 0.20 or better -'~~' Skylight U-factor - 0.58 or better NFRC stieker• must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake -Integrated Fireblocking r' Weather Resistive Barrier Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 5 Building Pem~it #03-088 REQUIRED INSPECTIONS APPROVED/DATE INSULATION ,. Floor (R-30) ~ f Walls (R-21) ,~-. ~ ~ Ceiling (R-3-3 8) Baines '~`'• ,., Vapor Barrier -paint ~~ 6 mil black poly in crawl space 3 1/2 i h l b i l ~ ~ ~` nc s n craw a space DRYWALL NAII.,IlVG Walls Ceiling ~ Garage House Occupancy Separation ~ „ ~ , , FINAL Public Works Sign-off LPG ~) House Numbers - 5" numbers Plumbing // ,~'-~` Mechanical/Heating Insulation Certificate Vapor Barrier Paint Certificate Fresh Air Certification for Integrated System Smoke Detectors ,/ ~ ~ Stairs, Decks & Landings ' Final -building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut tlow„ while this is accomplished. 2. Temporary erosion and sediment control (TESC) measu,•es slt:,ll be inst:,lled on-site and inspected prior to beginning construction; ca11385-2294. n'le;,sures shall include installation of silt fencing and graveled construction entr:,nce (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent prope,-ties. 3. All elements of engineering including nailing, holdowns, sl,eatl,ing, anti alternate braced wall panels (ABWP) require inspection prior to cover. • CaI148 hours before you dig for utility tine locates 1-800-424-5555 Page 4 of 5 C f Waterman & Katz Building 181 Quincy Street Suite 301 Port Townsend, WA 98368 Phone (360) 379-3208 Fax (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD03-088R-1 Issued: 06/17/03 Parcel Number: 963 700 012 Job Address: 111 Vista Blvd. Zoning: R-II Type: V-N Occupancy: R-3/U-1 Total Occupant Load: No Change Nature of Work: Revision #1: Add foundation pony wall to existing stem wall alone west side of foundation. Owner: Bruce Logan Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE BELOW SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See also original Inspection Record for additional required inspections REQUIRED INSPECTIONS APPROVED/DATE FOUNDATION Pony Wall .-'- Blocking Sheathing - Nailing Venting (16 total) FRAMING -all deck framing members to be pressure " treated or wood of natural resistance to decay. ti Step -Rise and Run FINAL -refer to original inspection record GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and aCity- business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Building Permit #BLD03-088R-1 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt - and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. A11 building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Buildin Department at 379-5086 rior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2