HomeMy WebLinkAboutBLD03-082~ ' Waterman & KatzBuilding
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone:(360)3A4-3057 Fax: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-~g2 Issued: ~ /14/03 Parcel Number: 972 902 501
Job Address: 892 53`d Street Zoning: R-I Type: V-N Occupancy: R-3
Total Occupant Load: 2/2 Nature of Work: Construct ADU with studio below
Owners: Markus Koch & Jill Silver
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.nTTTRFn TN~PF("TTnN~
APPRnVFT)/nATF
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Porch/Deck/Stair Piers
LIFER
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Permit # BLD03-082
REQUIRED INSPECTIONS aPPU~vFnmaTF
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts
Waterproofing
GROUNDWORK PLUMBING
Pressure Test
Pipe Joints Exposed
Pipe Bedding
FLOOR FRAMING
NOTE: Engineered BCI f Zoor plan on-site and
available to the Inspector at inspection time
Floor Beams
Joists
Blocking
Positive Connections
Treated Wood to Concrete
Anchor Bolts & Washers
PLUMBING:
Rough-In (D-V-T & Clean outs)
Gas Supply for LPG Stove (direct vent)- provide specs
on-site
Water Supply
Water Hammer Arrester @ dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint -strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
LPG Stove
Source Specific Exhaust Fan @ kitchen (100 cfm)
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from openings)
Whole house fan -bathroom
t
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
r
Permit # BLD03-082
RF,OI TIRED INSPECTIONS APPROVED/DATE
FRAMING
Walls
Braced Wall Panels
Ceilings
Roof
Blocking
Rafter Positive Connections
Roof Venting - eave and ridge vents
Deck/Stairs
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better for unlimited glazing
NFRC window sticker must be on windows, skylights &
doors at inspection time
Skylights U-factor - .58 or better
Fresh Air Intake (Wall Ports)
Solid Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-21 )
Ceiling (R-30 )
Vapor Barrier: paint on walls; plastic on ceiling
Baffles
DRY WALL NAILING
Walls
Ceiling
Occupancy Separation for owner's private studio/ADU
FINAL
Public Works Sign-Off
House Numbers - 5" minimum
Plumbing
LPG
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Stairs, Decks & Landings
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
i 11
Permit # BLD03-082
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3.208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
L`
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4