HomeMy WebLinkAboutBLD03-079r i • • Waterman & Katz Building 181 Quincy Street, Suile 30l Port Townsend, WA 98368 Phone:360-379-5086 Fax360-385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-~79 Issued: 4/25/03 Parcel Number: 948 308 207 Job Address: 1079 17th Street Zoning: R-II Type: V-N Occupancy: RR=3 Total Occupant Load: 5 Nature of Work: Construct Single-family Dwelling Owner: Darren Brady Contractor: Darren Brady-BRADYC*990B0 GENERAL CONDITIONS APPLY: See last sage SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 R F.C1T TTR F.ll TNCPF.f'TT(1NC A PPR (1VFT)/n A TF. TEMP EROSION & SEDIMENT CONTROL See. General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks Footings Forms Reinforcement Interior Footings Porch footings LIFER FOUNDATION .., Stem Wall ~~ ~ ~ ~ ~~~ Forms Reinforce**~P.,y,.,~_.-.~-.--_. ~. Anchor Bolts & Washers Post to Foundation Wall Positive Connection Holdowns CALL 48 hours before you dig for Utility line locates 1-800-424-5555 .Page 1 of 4 Building Permit #03-079 REQUIRED INSPECTInNS A PPR (1VF.i)/il A TF. FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time Joists Blocking Positive Connections Treated Wood to Concrete Anchor Bolts & Washers ~ ~~~i~63 PLUMBING Rough-In (D-V-T & Clean outs) Water Supply QK $~~f1D3 Water Hammer Arrestors LP Gas Supply Ho - backflow rotection required Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground MECHANICAL LPG Stove /Fireplace -provide specs on-site Marrufacturer'.s installation instructions to be on-site @ time of inspection. Source Specific Exhaust Fans @ bathrooms (SOcfm), laundry room, (50 cfm) and kitchen (100 cfm) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whole house fan -bathroom ls`fZoor i s Call 48 hours before you dig for utility line locates 1-500-424-5555 Page 2 of 4 Building Permit #03-079 .~ RF.nT 1TRF.D iN~PECTiONS APPROVED/DATE • ~~ ~J -• F1tAMING Walls Shear walls Shear Panel Blocking Roof Joists Joist positive connection Attic venting -gable & eave Posts, beams and headers ` ~ ~R~ ~ ' Windows -escape ~ ~'~ ( ~~~ ,f ! ~: ~ ,l Windows -safety glazing ~~ Window U-factor - 0.40 or better Door U-factor - 0.20 or better Skylight U-factor - 0.58 or better NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake -window ports Fireblocking h r Resistive Barrier - . ____ c ~c acs INSULATION Floor R-30) _.. _____.___. ..__ _ ___ _.__.__. _ -__.___..__.~~_~______ Walls (R-21 -_--~ r g( Baffles _~ -_ .._ .__.~_._ , ~_ -Vapor Barrier -paint DRYWALL NAILING ~ ~ Walls !';.t ~ ~~ ,.i ~ _ ~-- ~ z. f,,,~-r ` =-;~% Ceiling _ ~ _ - ncy-S~p i n FINAL ~`` Public Works Sign-off House Numbers - 5" numbers _ ' . , Plumbing i~ . '~ LPG ' ~ ,. Mechanical/Heating ? ~~~~ r ~ ~~' Insulation Certificate '~ fA - Vapor Barrier Paint Certificate - Smoke Detectors ~ /~ Stairs, Decks & Landings Final -building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Pemtit #03-0'79 .~ 1 -_ GENERAL CONDITIONS 1. Contractors working on this project are required to have a-Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way sha116e kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc, once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A m>In~mum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates ~" 1-800-424-5555 Page 4 of 4 Waterman & Katz Building l81 Quincy Street, Suite 30] Port Townsend, WA 98368 Phone: 360.379-5086 Fax360-3857675 CITY OF PORT TOWNSEND • M CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD03-079R-1 Issued: 05/13/03 Parcel Number: 948 308 207 Job Address: 107917th Street Zoning: R-II Type: V-N Occupancy: R-3 Total Occupant Load: No Change Nature of Work: Revision #1: Increase concrete foundation wall height from 8 feet to 9 feet. Owner: Darren Bradv Contractor: Darren Bradv - BRADYC*990B0 GENERAL CONDITIONS APPLY: See last cage SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept, of Labor & Industries 360-417-2702 NOTE: See original permit for all other inspections. RE UIRED INSPECTIONS APPROVED/DATE FOOTINGS -per attached engineering Setbacks Footings -~ ~ y / ~ ~' Forms Reinforcement - #5 @ 8", up to 4 feet,; #4 @ 16" o.c. U ~'{ ~` a `~ FOUNDATION -all elements of engineering ,, require inspection prior to cover Stem Wall ~~ " Z- C'~j Forms Reinforcement CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 2 Building Permit #03-079R-1 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wail panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2