Loading...
HomeMy WebLinkAboutBLD03-077r t Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: 360-379-5086 Faa 360J85-7675 CITY OF PORT TO~`~NSEND .~ ~ , t CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-077 Issued: 04/22/03 Parcel Number: 936 903 201 Job Address: 1392 Rose Street Zoning: R-II Type: V-N Occupancy: R-3 Total Occupant Load: 5 Nature of Work: Construct Single-family Dwelling Owner: Steven and Lisa Anderson Contractor: Same as Uwner GENERAL CONDITIONS APPLY: See last page SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 RF.(1TTTRF.TI TNCPF.f'TT(1NC TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS ~ Setbacks Footings ~'~- -°~ ~~ Forms R i ment Porch Piers Deck ER ` FOUNDATION ~'~ ~r ~ ' ' ~` .~~ ' Stem Wall ~ y - _ ~, - a Y,r;Sf ~~ ~J F Forms Reinforcement Anchor Bolts & Washers Engineered Holdowns Waterproofing CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 4 RE UIRED INSPECTIONS E . Building Permit #03-077 APPROVED/DATE GROUNDWORK PLUMBING Pressure Test Pipe Joints Exposed Q~_ i~ g14 f ~3 Pipe Bedding SLAB Insulation-R-IOfully insulated 7 ,/~ ~ ~'~~~ ~ ~ ~ ,- '1 ~ ' " ) Hydronic Heat Tubing ~ _ .,, ~ FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time Hydronic Heat Tubing Joists Engineered Floor Beams Blocking Positive Connections Treated Wood to Concrete Anchor Bolts & Washers PLUMBING Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrestors Gas Supply Hose Bibbs - backflow protection required Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water HeaterBoiler -manufacturer's installation instructions shall be on-site Drain to exterior Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground MECHANICAL Boiler Whole House Fan -Bath Laundry room, (50 cfm) and kitchen (100 cfm) Environmental air exhaust ducting (with backdraft dampers), insulation (R-4) and terminus (3' from openings into, building) Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 .~ t r i i 1?Ff1TTTT2FTl TNCPF.f TTf1NC Building Permit #03-077 APPROVED/DATE 1\L V11\1I Z/ f FRAMING Walls ;, _-.-~~ , -_, -~~ - _ ~' a Engineered Shear Walls ~ ~~ Roof x Rafter positive connection Attic venting -ridge & eave , ~ Engineered Posts, beams and headers `,, ~` Attic Access Windows -escape Windows -safety glazing ~ Window U-factor - 0.40 or better ~. Door U-factor - 0.20 or better Air Seal Fresh Air Intake -wall ports Fireblocking Weather Resistive Barrier r `' a INSULATION i Floor (R-30 ) Walls (R-21) Ceiling (R-30/R-38) _~affles . ~.-Y...~ _ ., _ . Vapor~arner -paint DRYWALL NAILING Walls ~_ Ceiling _ ~~ Enclosed Usable Space under Stairs FINAL ~ ~ ~ ;.'~ : _ `, ~ - ,,_ ,f,~ ~-° i;;~ y Public Works Sign-offer `` ~ 5" b N b H ,~, ers. ~ num ers - ouse um T R Plumbing ~=~' , f~ ~ ~ ,~ ..~ ~ -~ ~ r v. ~".~~ ~ -~ _~ - ~ ~_,. ,~'--~°~ ~ , ~,~ " , . MechanicaUHeating ~ ~ {~ , _ -ter ~ 7~ l . ~~- Insulation Certificate ~- f ~` ~ < % . w ',_ - `~_. {.~-~~ ~~-~ Vapor Barrier Paint Certificate ~ ~ ~```~- _ Smoke Detectors , ~~ "~ ~ Stairs, Decks & Landings =` r y Final -Building -~ ~ -'r" _ ' ~~ ~ ~. ,° ( Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 ~~ ,~ ~- .. Building Permit #03-077 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (1'ESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your'project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is reauired. Public Works approval must be received prior to scheduling the Buildins Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project.. 8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call'48 hours before you dig for utility line locates 1-800-424-5555 Page4of4 _ - ~~