CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-~73 Issued: 04/16/03 Parcel Number: 948 003 802
Job Address: 1217 32"d Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: No Change Nature of Work: Add mudroom/porch to residence.
Owners: Sally Pfaff and Monte Reinders Contractor: Brady Construction - BRADYC*990BQ
GENERAL CONDITIONS APPLY: See Last Page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
R F(1T iTR F T) TNCPF.('TT(1NC
APPRnVF.T)/T)ATF,
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfzll or other approved off-site location
meeting all state and local codes
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Porch Piers
FOUNDATION
Stem Wall a >G ~ "- l
Forms 63
' 1~
Reinforcement ~
t
Anchor Bolts -1/2"x 10"
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 3
Building Permit #03-073
RFniIiRFn iN4PF.('.TInN4
FLOOR FRAMING
Beam
Joists
Blocking
Treated Wood to Concrete
Positive Connections
Anchor Bolts & Washers
Crawl Access
Porch Post Bases
Min. 2 underfloor vents for cross ventilation
FRAMING
Walls
Ceiling/Roof
Attic Venting -vented
Window -safety glazing
Rafter Positive Connection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION (if applicable -unheated mudroom)
Floor (R-30)
Walls (R-21)
Ceiling (R-38)
Vapor Barrier: paint
Bafl`les
DRYWALL NAILING
Walls
Ceilings
FINAL
House Numbers - 5" numbers
Porch/Landings/Steps
Insulation Certificate if applicable
Vapor Barrier Paint Certificate
Smoke Detectors throughout
Final -building
eppunvFnm a •r~
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Building Permit #03-073
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Tempora-y erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent. rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project. until Public
Works requirements have been completed and inspected. For Public Works inspection call
• 385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.