HomeMy WebLinkAboutBLD03-036~ watermac, ar Katz Building
I8t Quincy Street, Suitc Sot
Port Towiuend, WA 98368
+ Phone: (360) 379-3208 Fax: (360) 385-76'75
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-036 Issued: 03/05/03 Parcel Number: 988 802 005
Job Address: 1104 Madison Street Zoning: R-II Type: V-N Occupancy: R-3
Nature of Work: Repair porch -install concrete footing, foundation and floor foists, and replace/repair
existing post and beams under existing residence as needed. Remove concrete walk nett to north wall.
Owners: Bruce & Mariana Van Blair Contractor: Discovery Bav Construction - DISCOBC090B9
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RF.(1TTTRF.T) TNCPF.f'TTnN~
APPRnVFn/nATF.
DEMOLITION
Materials from deck demolition shall be deposited in
areas off-site that meet all state and local laws
TEMPORARY EROSION & SEDIMENT
CONTROL
See General Condition No. 2 -install on-site as needed
during construction to prevent sediment from leaving the
site and to eliminate tracking of soil onto the street
FOOTINGS
Setbacks - no change n
~~ ~ ° 1 `
~
'
or
~,IZ ~ 03
Footings
Forms
Reinforcement
FOUNDATION
Stem Wall
Forms
Reinforcement
~ 1 ~ O 3
Anchor Bolts
Treated Posts to Foundation Wall Connection
Post Base
Girder to Post Positive Connection
Treated Wood to Concrete
raw Access enting
6 mil blac po y un er ouse
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
..
Permit # BLD03-036
FLOOR FRAMING
Beams
Joists
Hangers
Positive Connections
Post-to-Foundation Wall
Positive Connections
Treated Wood to Concrete
Post Bases
Treated Sill Plate
FRAMING
Posts
Porch Railing -less than 30"
Door Threshold
~y
-.-~
FINAL
House Number -check for 5" numbers 4
Smoke Detectors throughout existing
house per 1997 UBC ~~
Final -building > (;, ,
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced waU panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit # BLD03-036
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions from the
Building Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3