HomeMy WebLinkAboutBLD03-034Watc~man 8c Katz Building
181 Quincy Strut, Suite 301
Port TowRUend, WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-034 Issued: 03/06/03 Parcel Number: 968 500 044
Job Address: 4053 41n Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: 6/2 Nature of Work: Construct single-family residence with attached garage
Owners: Richard & Debbie Thomas Contractor: Campbell Construction-CAMPBC-111LR
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-4I7-2702
NOTE: All elements of engineering require inspection prior to cover
RE(~TTTRF.n TN4PF.("TTnN~
APPRnVEI)/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
~ ~:; t ~ ~ r ~ ~'~°~( ~-~.-r -~ ~~'!„'~
Footings
Forms -~
~-~ C ~--
~
(l ~ I p 3 i' c S 5-~
Reinforcement -
'
- Interior Footings f ;~ ~. c~ ~:~ v ~-
Porch/Deck Piers
UFER
•
'-
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Permit # BLD03-034
REnUiRED lNSPE C_TTnN4 . A PPR (1VF.1)m A TF.
FOUNDATION
Stem Wall I
~ f 2 y ~ U3
Forms ~ a S 5--~~ ~ cC._.
Reinforcement ~ ~ `,i,,,p,J~
Anchor Bolts & BP washers
FLOOR FRAMING
Joists -engineered BCI plan shall be on site at time of ~`
U
~ ~~
Inspection
~
Beams Q S,~ ~J ~`~/v3
Blocking ~ ~, ~
Positive Connections
~ cti;
Treated Wood to Concrete ~, k~-
Anchor Bolts & Washers
Post to Foundation Wall Connection
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Gas Supply
Water Hammer Arrester @ clothes & dishwashers 6 ~
Hose Bibs (backflow protection required) ~`~
Pipe Insulation (R-3)
s -16-x3
Pressure Reduction Valve if > 80 psi
Water Heater
R-IU under if electric
Seismic Restraint -strap tank @ 1/3 points
18" A. F. F.
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL 1 • c~wFS ~t o!, ~ Be e3
Whole house fan -Utility Room
LPG Stoves - provide specs on-site
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
J
Call 48 hours before you dig for utility line locates
1-800.424-5555
Page 2 of 4
Permit # BLD03-034
RF.(lT1TRFT) TN~PF(".TTONS APPROVED~DATE
- -- - ---- -- - - - -
FRAMING
1
~ A , Fa t ~ ~ . - , ~, •:I c'~ _ ~ ~. 3a ~ -~
f
-~ -~« -~ ~ ~ _~~~~ •
Interior braced wall panels
Ceilings/floor -engineered LPI plans to be on site
Roof -Engineered truss plan to be on site at inspection
Blocking
Truss Positive Connections
Roof Venting - eave and gable vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better for unlimited glazing
1VFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake -Window ports
Doors U-Factor - .20 or better/Rated doors @ garage/house
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION t ~, ~°_ ~ ~'"rt ,~,: ; "~ C ~
Floor (R-30 )
Walls (R-21 )
moiling (R-38) _ _.._ _
Vapor Barrier: paint
Baffles
6 mil black poly
DRY WALL NAII.ING
Interior braced wall panels f '~~~
~~~:` ,~ ; `f ',- ' ~ ~~ -
Walls ;
Ceiling A
Garage/House Occupancy Separation
FINAL
Public Works Si
LPG ~, `'' ~-- ~ , ~~, `' ~-~ /~
House Numbers -~5" minimum
/~
Plumbing ~ i
~,,~ ,~ , ~ ,%- ~
~ "~ { ` ~ ~~~ ~ ~~ ~'
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page3of4
r.
Permit # BLD03.034~
•
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is.accomplished.
Z. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings; sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require, inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no~progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active. ---
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4