Loading...
HomeMy WebLinkAboutBLD03-022Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDU3-~22 Issued: 03/12/03 Parcel Number: 972 900 701 Job Address: 605 T Street Zoning: R-II Type: V-N Occupancy: R-3/U-1 Total Occupant Load: 7/2 Nature of Work: Construct single-family residence; remodel ADU/Garage (install garage door, engineered steel beam, new windows and siding). Owners: Garv & Marv McDowell Contractor: Seraphim Builders GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 • REQUIRED INSPECTIONS APPRnVFn/nATF, . ~rcn,ru cnnciniv x. ecnTnrtcnrr inn TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS ~<<{~-~. F ;- --, ~,_-~ ~~~~, ~ ~' . -- j ; ~-- Setbacks ~ J ~ ~ ~~~~ .. ~ ~~ C ~-- ? fro C Footings m F ~, ~ ~' 3~/3 ~ ~ ~ J ~ or s , - Reinforcement ~~ Interior Footings ~ ~' ~<, . `' Fireplace Footing k Pi ,~` / ~ ~~ ' rs Porch/Dec ~ ~ ' ~ 1 . ~ LIFER ---- `~ ~. ~ l 1 ~~ I~ Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Pcmvt # BLD03-022 REQUIRED INSPECTIONS APPROVED/DATE FOUNDATION Stem Wall ' Forms ~ ~' Reinforcement ~ Anchor Bolts & BP washers Vents -11 re uired g q ~_ ~ r , Crawl Access W G d 3 l Engineered Holdowns j SLAB (@sunroom) Thickened footing per engineering @ ADU Forms Reinforcement FLOOR FRAMING ~ S ~ ~ ° ~ NOTE: Engineered BCI f loor plan on-site and - available to the Inspector at inspection time ~a, Joists ~ ~ ~ ~~ -3 Beams Blocking Positive Connections Treated Wood to Concrete ~ Anchor Bolts & Washers ~ PLUMBING: Rough-In (D-V-T & Clean outs) Water ~' ~" ~' ~ 'Z s .- ater Hammer Arrester c othes d hwashers '-~~- -~ Hose Bibs (backflow protection required) Pipe Insulation (R-3) b ,E Pressure Reduction Valve if > 80 psi er ~-3-a3 Seismic Restraint -strap tank @ 1/3 points 18" A. F. F. Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL Whole house fan -Attic y ~ ~ ~ / LPG Boiler -provide specs on-site `~ ~ 3 • ~3 S urce S ecific nvironmental Air Exhaust ducting (w/ backdraft dampers), sulation (R-4) and terminus (located 3' from openings) ~~ ~~~ ~~ Ca1148 hours before you dig for utility line locates 3 ~ v ~ ~~ 1-800-424-5555 Page 2 of 4 ~/ w r 1 ~ lam` . , ~ ~~. -r: ~ . R F.(1T TTR FTl TNCPF f'TT(1N4 FRAMING Walls __~ ~ __ _ ___.____._ __._. ~__ Engineered shear walls ~ Ceilings/floor Roof Blocking Posts, Beams and Headers Rafter Positive Connections Roof Venting - eave and ridge vents Fireplace masonry -wood clearances Windows -escape Windows -safety glazing b ~ ~~ ` Windows Ufactor - .40 or better for unlimited glazing !~ - NFRCwindow sticker must be on windows & ~, 3.0 ?J doors at inspection time Fresh Air Intake -Window ports Doors U-Factor - .20 or better/Rated doors @ garage/house Air Seal !~ ~ r -i t ~', ~ !~"' ? !--' , ~~ . Fire Blocking Weather Resistive Barrier t INSULATION _ _ ~ Floor (R-30,) _ 1 alls (R-21) ~ ... ~, _~: .~. _ , ~ - f ..,_ ~ - Ceiling (R-3 8) (R-3 0 @ vaulted) - ~Vapor Barrier: paint ,,~ .~ ~'~ ~ ~, ~ f,.. r ~ ~~,, Baffles 6 mil black poly DRY WALL NAILING ced wall anels I terior br ~, ~5 '~' ~` ~~ ~ ~ ~~,rl~~ ~~ 1 ~~ p n a 'dab ~~ ~ tt ~ '7 Walls ~ / J Ceiling Garage/ADU Occupancy Separation ADU /Breezeway separation FINAL ,,~; Public Works Sign-Off ~ _1 LPG House Numbers - 5" minimum Plumbing MechanicaUHeating Vapor Barrier Paint Certificate Insulation Certificate ~-' Smoke Detectors +~ Final - Buildin ' Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 ~~ f r. ,f .6, v f `' ~~ ~ ~ -~. t ., ~~ ~F, ' ;~ ; ' ~, / e , ` ~ Pemvt # BLD03-022 - -~ APPROVED/DA E ~~~ ~~,~ ~ a ., F,~ 1. r ~', ~~ C-~ Permit # BLD03-022 GENERAL CONDITION 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and"oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works aunroval must be received urior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval grior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 Waterman ~ Katz Building 181 Quincy Street, Suite 301 Port Townsrnd, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD~3-U22R-1 Issued: 04/17/03 Parcel Number: 972 900 701 Job Address: 605 T Street Zoning: R-II Type: V-N Occupancy: R-3/U-1 Total Occupant Load: No change. Nature of Work: Revision #1: Change interior slab at Sunroom to wood floor svstem. Owners: Gary & Marv McDowell Contractor: Seraphim Builders - SERAPBI984CH GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See original permit BLD03-022 for other inspections. I''" L (REQUIRED INSPECTIONS APPROVED/DATE FOOTINGS/FOUNDATION ' Sunroom changed to footing/foundation wall. ~' °, Add 2 Foundation Vents to Sunroom. Crawl Access -provide access to Sunroom SLAB Change to joist system in Sunroom. FLOOR FRAMING Joist system in Sunroom. Hydronic Tubes (if applicable) Refer to original permit for other inspections. INSULATION -see original permit for floor insulation requirements. Floor (R-30 ) FINAL -see original permit _ Final -Building Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pemtit # BLD03-0228-I GENERAL CONDITIONS 1. Contractors workin on this ro'ect are re wired to have a Labor & In u ries c r' g p I q d st ontracto s re~stration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. Alt elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294, A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. _ 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval rior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2