HomeMy WebLinkAboutBLD03-021* Waterman 8c Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: (360) 379-3208 Fax: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-021 Issued: 04/04/03 Parcel Number: 985 800 701
Job Address: 1775 Fir Street Zoning: R-II Type: V-N Total Occupant Load: 2
Occupancy: U-1 Nature of Work: Construct detached ~araQe/shop with radiant floor heat.
Owners: Charles and Lucv Hanson Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RFnTTTRFT) iN~PF(~TT(~N~ APPR(~VF,n/nATF,
TEMPORARY EROSION AND SEDIMENT
CONTROL
'e General Condition No. 2 and attached MIP03-010
gilt Fence as needed
Drive Off Mat to restrict sediment from leaving the site
FOOTINGS
Setbacks ~/~~
~ ~C /~' ~
Footings fo /z¢1 ~
Forms
Reinforcement
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts & Washers
Alternate Braced Wall Panel Holdowns
Treated Wood to Concrete
Positive Connections
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Permit # BLD03-021
REQUIRED INSPECTIONS APPROVF.nmATF j
SLAB - - - - _---
R-10Insulation under entire slab
Hydronic Floor Tubing
G
d
k Pl
bi
~
roun
wor
um
ng /
'
~
Pressure Test ~,/
Pipe Joints Exposed
Pipe Bedding ~ '
/ C/~ ~
PLUMBING:
Water Heater
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
Pressure Reduction valve required if over 80 psi
Hose Bibbs (if applicable) with backflow prevention
18" Above Finished Floor
FRAMING
Walls
Engineered Shear Walls
Headers & Beams
Treated Wood to Concrete
Ceiling/Roof
Truss Positive Connection - eng7neered truss plan on-
site @ time of inspection
Roof Venting - @ eave & ridge
Windows U-factor - .40 or better ~-/
NFRC window sticker must be on windows ~
and doors at inspection time /` ,
Skylights - .58 or better 1
Air Seal
Fresh Air Intake (Window Ports) `
Doors U-factq
r - .20 or better J
_
Fire Blocking
Weather Resistive Barrier
Alternate Braced Wall Panel
INSULATION
Slab (R-10 under entire slab )
Walls-(R-11)
~ C,
Ceiling - (R-30 )
Bai~les
Vapor Barrier: paint
~ ~`
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit # BLD03-021
RE UIRED INSPECTIONS APPROVED/DATE
DRY WALL NAILING _.-- -,-.~_
,~, ~~
Walls - ~ j
~,/ - `
eiling _....._ U ,r
FINAL
Public Works Sign-Off
House Numbers - 5"minimum
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall 6e permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility hne locates
1-800-424-5555
Page 3 of 3