Loading...
HomeMy WebLinkAboutBLD03-014 • Waterman & Katz Building 181 Quincy St., Suite 301 Port Townsend, WA 98368 Phone (360) 379-3208 Fax: (360) 379-6923 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-014 Issued: 02/06/03 Parcel Number: 931 200101 Job Address: 1233 Van Ness Zoning: R-II Type: V-N Occupancy: R-3 Nature of Work: Replace door and window in unheated mudroom with window_unitLrepair porch piers and floor framing as needed. Owner: Eugene Bricklernyer Jr. Contractor: Owner (385-7679) GENERAL CONDITIONS APPLY -SEE BELOW SEPARATE PERMITS REQUIRED: Electrical -Contact WA State Labor & Industries @ 360-417-2702 REOITIRED INSPECTIONS APPROVED/DATE FOOTINGS I 4 S ~ ~- C._-~. ~ ~ ~ l C ~ Porch Pier Footings ~ Reinforcement ~~,r. ~ ~,~,.~,, ;~~ Post Base/Shield under Posts Positive Connection -post-to-beam Treated Wood to Concrete FLOOR FRAMING 3 (2 K 1 ~~ Q S.~-~'~ ~- LL- ( ~ r Ledger Detail Girder 1~,,- ~,e, ~v-~~~~~- j Joists Blocking Positive Connections Treated Wood to Concrete Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 Permit #BLD03-014 ~~ FRAMING Header Walls Window U-factor -unheated space Window Safety Glazing -safety glazing required in windows located within 24" arc of either edge of door Ceiling Blocking Positive Connections Weather Resistive Barrier INSULATION Walls -inspection @ preference of homeowner as enclosed space is considered unconditioned DRYWALL NAILING (if applicable) Walls Ceiling , FINAL Smoke Detectors (SD) -required throughout per 1997 Uniform~Building Code (UBC): one in each sleeping room and in area/hallway leading to each sleeping room with minimum one SD on each floor; battery powered OK Building Numbers -check @ final Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed .during construction shall be temporarily stabilized with mulching,. plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP} require inspection prior to cover. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 1 Permit #BLD03-014 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection cal1385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. PO5T THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3