HomeMy WebLinkAboutBLD03-014
•
Waterman & Katz Building
181 Quincy St., Suite 301
Port Townsend, WA 98368
Phone (360) 379-3208 Fax: (360) 379-6923
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD03-014 Issued: 02/06/03 Parcel Number: 931 200101
Job Address: 1233 Van Ness Zoning: R-II Type: V-N Occupancy: R-3
Nature of Work: Replace door and window in unheated mudroom with window_unitLrepair porch piers
and floor framing as needed.
Owner: Eugene Bricklernyer Jr. Contractor: Owner
(385-7679)
GENERAL CONDITIONS APPLY -SEE BELOW
SEPARATE PERMITS REQUIRED:
Electrical -Contact WA State Labor & Industries @ 360-417-2702
REOITIRED INSPECTIONS
APPROVED/DATE
FOOTINGS I
4 S ~ ~- C._-~.
~ ~ ~ l C ~
Porch Pier Footings ~
Reinforcement ~~,r. ~ ~,~,.~,, ;~~
Post Base/Shield under Posts
Positive Connection -post-to-beam
Treated Wood to Concrete
FLOOR FRAMING 3 (2 K 1 ~~ Q S.~-~'~ ~- LL-
( ~ r
Ledger Detail
Girder 1~,,- ~,e, ~v-~~~~~-
j
Joists
Blocking
Positive Connections
Treated Wood to Concrete
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Permit #BLD03-014
~~
FRAMING
Header
Walls
Window U-factor -unheated space
Window Safety Glazing -safety glazing
required in windows located within 24"
arc of either edge of door
Ceiling
Blocking
Positive Connections
Weather Resistive Barrier
INSULATION
Walls -inspection @ preference of
homeowner as enclosed space is considered
unconditioned
DRYWALL NAILING (if applicable)
Walls
Ceiling ,
FINAL
Smoke Detectors (SD) -required throughout
per 1997 Uniform~Building Code (UBC): one
in each sleeping room and in area/hallway
leading to each sleeping room with minimum
one SD on each floor; battery powered OK
Building Numbers -check @ final
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed .during construction shall be temporarily stabilized with mulching,. plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP} require inspection prior to cover.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
1
Permit #BLD03-014
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection cal1385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress has been made within sia months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. PO5T THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
• Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3