Permit Number: BLD03-0~7 Issued: 02/13/03 Parcel Number: 988800905
Jab Address: 826 Ouincv Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: NC Nature of Work: Add bedroom; convert bedroom to bath and
closet
Owner: Lois and Bob Thompson Contractor: Same as Owner
GENERAL CONDITIONS APPLY: See Last Page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 3b0-417-2702
RF.it1TTTRF.TI TNCPF.f''TT(1NS
APPR(~VF.n/nATF
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfill or other approved off-site location meeting
all state and local codes
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Interior Footing
Deck Piers
UFER
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
Building Permit #03-007
REnIJIRED iNSPEC:TinNS APPRnVF.I)/>7ATF.
FOUNDATION
Stem Wall '
Forms
Reinforcement
Anchor Bolts
Vents
Crawl Access
Beam Pockets
FLOOR FRAMING
Girder Beam
Joists
Blocking
Treated Wood to Concrete
Girder to Concrete
Beam Pockets
Positive Connections
Anchor Bolts & Washers
PLUMBING
Existing
MECHANICAL
No new -bedroom only
FRAMING
Walls
Ceiling/Roof
Attic Venting - @ eave & ridge
Windows -escape
Window U-Factor - .40 or better
Door Ufactor - .20 or better
Rafter Positive Connection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30
Walls (R-21)
Ceiling (R-30 in vault)
Vapor Barrier required: paint
Baffles
6 mil black poly in crawl space
J
J
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Building Permit #03-007
•
RE UIRED INSPECTIONS
DRYWALL NAILING
Walls _
~ ~-;_. ' ~ Z ~ ~ ~-____________
i
.~,ilirigs .._-_.._.._~ ____------
FINAL
House Numbers - 5" numbers y. '~~
'~
Decks/Landings , ~ ,
_, r
Insulation Certificate if applicable
!
Vapor Barner Palnt Certificate ~
_
-
Smoke Detectors throughout _ --~
Final -building ~-'
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
APPROVED/DATE
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Permit #03-007
t
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. AU building permits expire if no progress bas been made within sia months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before ou dig for utility line locates
Y
1-800-424-5555
Page 4 of 4
a-
1
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: 360379-5086 Fa:360385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Job Address: 826 uinc Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: NC Nature of Work: Construct Detached Art Studio
Permit Number: BLD03-~~7R-1 Issued: 02/13/03 Parcel Number: 988800905
Owner: Lois and Bob Thom son Contractor: Same as Owner
GENERAL CONDITIONS APPLY: See Last Page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF.(1TTTRF.T) TNCPF.f'TT(1NC
APPR(1VF.T)/T)ATF.
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfrll or other approved off-site location meeting
all state and local codes
FOOTINGS
~
Z~ ~
~~ ~ 03 ~ ~ ~
Setbacks ~
~
gs ~ C- l- ~~ i~,~-~/~t'.-
ms
Fo
Reinforcement
Interior Footings
Deck Piers
LIFER
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
Building Permit #03-00'7R-1
REQUIRED INSPECTIONS APPROVED/DATE
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts
Vents
Crawl Access
Beam Pockets
Engineered Holdowns
FLOOR FRAMING
Girder Beam ~~ s~
Joists
3111 ~ v3
Blocking
Treated Wood to Concrete ~' ~-
Girder to Concrete
Beam Pockets
~~ ~
v
Positive Connections ~,,~
Anchor Bolts & Washers
Foundation Vents
PLUMBING
Rough-In (DW&V)
Water Supply
Hose Bibbs
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
" S
Seismic Restraint I
Pressure Relief Valve Drain to exterior; terminate 6" - 24"
above grade
MECHANICAL
Furnace
Ducting & Duct Insulation (R-8)
Whole House Fan - @ bath
Fresh Air -wall port
- -ti
Environmental Air Exhaust ducting (with backdraft damper), ~1i~
insulation (R-4) and termination (located 3' from openings ~,
into building)
Call 48 hours before you dig for utility line locates
1-800-424-5555
.J
Page 2 of 4
s
RF(17TTRF.iI TNCPF.fTT(1NC
Building Perntit #03-007R-1
APPRnVED/DATE
FRAMING
Walls
Engineered Shear Walls
Ceiling/Roof -engineered ridge beam
Attic Venting - @ eave & ridge
Window -safety glazing ; ~
~ L
Window U-Factor - .40 or better
Door Ufactor - .20 or better
Rafter Positive Connection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30)
Walls (R-21)
Ceiling (R-30 in vault)
i
d
: paint
re
Vapor Barrier requ
Ba#Iles ~j ~
6 mil black poly in crawl space
DRYWALL NAILING C4~-- =;r Z C13'
Walls _.._----
Ceilings 6~ s / ~, ~,
/` ~~' !.~
FINAL
House Numbers - 5" numbers
Plumbing
Mechanical
Decks/Landings
Insulation Certificate if applicable
Vapor Barrier Paint Certificate
Smoke Detector
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Petnvt #03-OOTR-1
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee. correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Pu61ic
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4