HomeMy WebLinkAboutBLD02-249Waterman & Katz Building 181 Quincy Street Suite 301 Port Townsend, WA 98368 (Phone) 379-3208 (Fax) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERNIIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD02-249 Job Address: 1151 Water Street Total Occupant Load: N/C Owner: Don's Pharmacy (360) 385-2622 Issued: 10/28/02 Zoning: CII Nature of Work: Contractor: Parcel Number: 989 701003 Type: N/C Occupancy: N/C l JLsU~~lC35 - 1~~ (253) 606-0525 GENERAL CONDITIONS APPLY -SEE LAST PAGE ~:~,.a SEPARATE PERMITS REQUIRED:- ~~C.~~'p'~ Electrical -Contact Labor & Industries @ 360-417-2702 Building Pernut- Required for Type 1 Hood fire suppression system. REQUIRED INSPECTIONS MECHANICAL -see attached UMC Appliance/Exhaust Interlock Exhaust Outlet Clearance - 2' above roof,• S' other Type I Duct Gage Duct Joints/Seams -continuous liquid-tight weld Grease Duct Supports - no penetration of duct walls Duct Slope -'/x:12 Duct/Enclosure Separation - 3"min.; 12"max Duct Enclosure/Shaft -one-hour construction Cleanouts Air Velocity - ISOOfpm - 2500 fpm Duct/Combustible Clearance - I S "; 3 "from non-combustibles Hood Flashing -less than 12 "from ceiling or walls requires flashing with 22 gage steel Duct Insulation -Make-up air: R-3.3 Grease Filters -see UMC 508. S Canopy Hood -installed per manufacturer's installation instructions ~~yp/b7i ,~~fov~ A Page 1 of 2 , Building Permit #BLD02-249 FINAL Fire Department Electrical (I,&I) Plumbing -separate permit for grease trap if needed. Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor &c Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required • inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is reauired. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to malting changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Page 2 of 2 ~,poa ~ ay~ CITY OF PORT TOWNSEND COMMERICAL KITCHEN INSPECTION AND TEST CERTIFICATE THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CALL 385-2294 FOR INSPECTION Permit Number: Issued: Date: O/ /o o '~ Job Address: ' Owner/Proprietor: Nature of Wor _ Use of Building. Contractor:.,Q~rk..:. ~a--- Contractor State License N er: -, • • ^ System orientation/installation in accordance with mfr's/UL listing and City permit Appliances properly covered with correct nozzle(s) (appliance mfr's listing) ~ Duct and plenum covered with correct nozzle(s) o~ Positioning of nozzles o~ Nozzle covers in place (where required) rd' Fusible links within rated temperature requirement .~w 4 0 Hood/duct penetrations sealed with weld or UL listed device ~ Cylinder pressure gauge in proper range (if gauged) ^ Hydrostatic test date of cylinder current (C02 cartridge exempt) ~~~~G~'n/ ~x~cir r,Y Inspect cylinder mount(s) Check travel of cable(s) e' Cable piping and conduit properly bracketed ~ Proper separation between fryer(s) and devices with surface flames ~ Proper surface to filters clearance ~ Exhaust fan in operating order 7-~ a- ~~ W~ Filters in proper orientation Fuel shut-off in "on" position for operation/test ~ Fan warning sign on hood ~ Manual release and location proper p~ Personnel instructed in manual operation of system ~k- ' e' Class K Fire extinguisher within 30 feet and tagged properly ^ 40-B:C Portable Fire Extinguisher available and tagged properly ^ Electrical panel properly labeled for shunt-trip function and manual reset, if applicable ^ Other: Inspector: Date: p / /o G 3 Date: A('('F,PTANC'F TEST r,~ Automatic Trip Test ~ Manual Trip Test ~ Fuel/Power disconnect for all hooded appliances/outlets (with manual reset) ^ Hood protection system monitored by premises automatic fire alarm system .v/ Certification/service tag on system Inspector: Date: C:\WINDOWS\Desktop\Tom's File Cabinet\Forms & Templates\Commercial Kitchen\Commerical Kitchen Inspection & Test Certificate.rtf 3/13/01 jpspP~rnr• O `~ Date: /4 a