HomeMy WebLinkAboutBLD02-186Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: 360.379-5086 Fax 360.3857675
•
C,
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD02-186 Issued: 09/16/02 Parcel Number: 989714103
Job Address: 405 Taylor Street Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: NC Nature of Work: Expand Single-family Dwelling
Owner: James & Barbara Ewing Contractor: Discovery Bay Construction
DISCOBC090B9
GENERAL CONDITIONS APPLY: See Last Page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF(1TTTRF.TI TNCPF.f TT(1NC
A PPR nVFn/n A TF,
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfill or other approved off-site location
meeting all state and local codes
FOOTINGS -per engineering
Setbacks
l~ ~(~~~
Footings 7
Forms
Reinforcement
Interior Footings
Deck Piers -existing
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts -okay @ 32 " o. c. per engineeing
Vents -open
Beam PocketlPositive Connection
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 3
Building Permit #02-186
REQUIRED INSPECTIONS
APPROVED/DATE
FLOOR FRAMING
Beam
~~ t`
Joists
Blocking
Treated Wood to Concrete
Positive Connections
Anchor Bolts & Washers
FRAMING
Walls
Ceiling
/a ~~~
Attic Venting -fill roof cavity with rigid
Window U-Factor - .40 or better
Windows -escape
Windows -safety glazing
Door Ufactor - .20 or better
Rafter Positive Connection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30)
Walls (R-21)
Ceiling (R-38)
Vapor Barrier: paint
Baffles
6 mil black poly in crawl
DRYWALL NAILING
Walls
Ceilings
FINAL
House Numbers - 5" numbers
Deck/Landings
Insulation Certificate if applicable
Vapor Barrier Paint Certificate
Smoke Detectors throughout
Final -building
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
GENERAL CONDITIONS
Building Permit #~02-186
1. Contractors workin on this project are required to have a Labor & Industries
g
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass fmal inspection on your project until Public
• Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's fmal inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
G
\ W
H
~ ~ ~
~ ¢
M ~ ~
Q
!~ W
~7 M Q Z
,1~` ~ Z O
O ~ O U
Z ~ >. M ~ w
,,,,, a
~ m ~ o z
d Z ~ > O
W cq
Q. j m N 0
\ 0 > _ ~
W 0 ~~ Zm
J F- p
W W zZ FZ-m
N o z} ~o ~~
R ~ ~ ~~ ~M
~ 7 ~ W Q p
~ O W Z d V
~ ~ a¢ ~o
0 O ~ =o ~m
°~ o ~~ OQ
a_ W
O ~ o Ov
E-
~1 ~ U M O O m Z
J~ W¢ OZ
~O
m~ >W as
Z ~ ww LL~
W W U °°> Oz
V ~ ~ Om O~
Q ~ ~ ZZ ¢_ _ZW
C~ ~ ~ aYC O m ~
~ ~ OW w~
p C') w~ h~-O
s ~Z o~ O
~ p~ ~w z
~ } ~ ~~ O
~ m H
~' ~ ~ U H ~ o
v~ ~
W Z O
~ Q z }
O ~ m ~
~ ~ _ ~-
~ ~ o d
~ Z
0
o }