CITY OF PORT TOWNSEND
•
•
•
CONSTRUCTION PERMIT & INSPECTION RECORD i,
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD02-185 Issued: 5/28/03 Parcel Number: 989 714 210
Job Address: 610 Hudson Place Zoning: R-II Type: V-N Occupancy: R-3
Total Occupant Load: 7 Nature of Work: Construct Single-family Dwelling
Owner: Mike & Shelly Reiss Contractor: Little & Little Construction-LITTLLC157C5
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
NOTE: Special Inspection is required for A325 high-strength bolts~er UBC Section 1701. S, item
6 and for piles as required in the Soils Report om Aspect Consulting. The Special Inspector for
the high-strength bolting shall be an ICBO certified inspector listed in the current edition of the
WABO "Agency and Inspector Register " or present ICBO credentials to the Building Department
prior to performing inspections. Special Inspection Reports shall be copied to the Building
Department in a timely manner. Permit Holder or Permit Holder's Agent shall review and oversee
correction of any and all deficiencies noted by required special inspections.
REQUIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL Per
attached permit #SDP02-032
FOOTINGS -per engineered details; all soil bearing ~-'~`~"f'~ ~ ~'- r °~'-~~~~~~~~~~. ~.-~~° .~ ~~~f^°~
surfaces shall be inspected by geotech prior to placement
of resteel and concrete as noted on Sheet A7 of plans
Setbacks
Pile Footings
Grade beams
Column Footings
Forms
Reinforcement -per engineering
Interior Footings and grade beams
Porch Footings
Deck Footings
LIFER
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 5
Building Permit #02-1$S;
a
REQUIRED INSPECTIONS APPROVED/DATE
FOUNDATION -per engineered details; all
elements of engineering require inspection prior to
cover
Stem Wall r
p `7~z-z~
Forms ~si a
Reinforcement -per engineered detail
c or o is & Was ers -per engcneere o own -'-~-_.,
schedule
Engineered Holdowns
Crawl Access
Foundation Vents
FLOOR FRAMING
NOTE: Engineered TJI floor plan on-site and
available to the Inspector at inspection time ~ g~Z~D3
Girders
Joists
Radiant Heat Tubing
B ocking
Hangers
Positive Connections
O
~~2(~D/
Treated Wood to Concrete
Anchor Bolts & Washers
Engineered Holdo s
~-3~~~~"o.~.®s~z ~~~..~ ~,~-t.~.,s
~ f 8103
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestors ~
Gas Supply f
Hose Bibbs - backflow protection required c"~
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi ./
Water Heater ~ ~~J
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate ~
6" -24" above ground
r
Call 48 hours before you dig for utility line locates .
1-800-424-5555
Page 2 of 5
~, ~~..
. r
~RE UIRED INSPECTIONS
D
,.
t. ,h Building Permit #02-185
A PPR(IVF.I)/nATE
1:~IECHANICAL
Boiler -manufacturer's installation instructions shall be on-
site at time of inspection
LPG Fireplaces -provide specs on-site
Whole house fan -Guest bath
Source Specific Exhaust Fans @ bathrooms (SOcfm),
laundry room, (50 cfm) and kitchen (100 cfm)
Environmental air exhaust ducting (with backdraft
dampers), insulation (R-4) and terminus (3' from
openings into building)
~_.
- ="-~~ ~; ~"'
`
~.
~ j
FRAMING
Walls -framing per shear wall designations ~-7' cc ~_ ~ E-F~t}~fL.. w
~ ~
~.~
~-- ~:=`~
~.
-~
~
Q~
~~
~,
Y ~
.
r
_
,
-
Engineered shear walls
Interior shear walls ~
Engineered moment Pram connections ,
-~
.~
Shear Panel Blocking ~ ,%
Roof -engineered truss plan shall be on-site at time of
inspection
Truss positive connection
Attic venting -gable end cg eave ~~~~=
Posts, beams and headers -per engineering f
Engineered Steel Columns and Beams
Windows -escape ~~-
Windows -safety glazing
Window U-factor - .40 or better
Door U-factor - .20 or better ~ ~"
Skylight U-factor - .58 or better
NFRC sticker must be on windows, doors & skylights at
time of inspection
Air Seal
Fresh Air Intake -wall ports
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-21) ~ ~ - .
Ceiling (R-38 )
Baffles _
Vapor Barrier -faced batts
6 mil black poly in crawl space
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 5
~~ ~
REQUIRED INSPECTIONS
Building Permit #02-185 ~
APPROVED/DATE
DRYWALL NAILING
Walls
Ceiling _
FINAL
Public Works Sign-off
LPG
House Numbers- 5" numbers
Plumbing
Mechanical
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Stairs, Decks & Landings
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall 6e
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Pu61ic
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 5
Building Permit #02-185
ion are re uired rior to occu anc • A Certificate of Occu anc is re uired
7. Final Inspect s q p p y~ p Y q
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 5 of 5
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: 360-379-5086 Fax 360.3857675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD02-185R-1 Issued: 6/30/03 Parcel Number: 989 714 210
Job Address: 610 Hudson Place Zoning: R-II Type: V-N Occupancy: RR=3
Total Occupant Load: 7 Nature of Work: Revision #l: Change foundation to Chance
anchors from auger cast piles
Owner: Mike & Shelly Reiss Contractor: Little & Little Construction-LITTLLC157C5
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
NOTE: ~ecial Infection is required for boltin~ofpile caps and Chance anchors per Uniform
Building Code Section 1701.5 and as required in the Soils Report from Aspect Consulting. Special
• Inspection Reports shall be copied to the Building Department in a timely manner. Permit Holder
or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by
required special inspections.
REQUIRED INSPECTIONS APPROVED/DATE
* *See also on final Ins ection Record
FOOTINGS -per engineered details; all soil bearing
surfaces shall be inspected by geotech prior to placement
of resteel and concrete as noted on Sheet A7 of plans
Setbacks
Grade beams
Forms
Reinforcement -per engineering
Interior Footings and grade beams
FOUNDATION -Chance anchors torque, driven depth,
attachment of pile caps, etc. require special inspection as
noted above
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 2
Building Permit#02-185R-1 ' '
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Pu61ic Works approval
must be received prior to scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the. Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates •
1-800-424-5555
Page 2 of 2
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: 360-379-5086 Fax 360-3857675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD i
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD02-185R-Z Issued: 07/09/03 Parcel Number: 989 714 210
Job Address: 610 Hudson Place Zoning: R-II Type: V-N Occupancy: R=3
Total Occupant Load: 7
Nature of Work: Revision #2: foundation grade beam modification and crawl space access.
Owner: Mike & Shelly Reiss Contractor: Little & Little Construction-LITTLLC157C5
GENERAL CONDITIONS APPLY: See last pale
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
NOTE: Special Inspection is required for bolting of pile caps and Chance anchors per Uniform
Buildin>? Code Section 1701.5 and as required in the Soils Report rom Aspect Consulting. Special
Inspection Reports shall be copied to the Building Department in a timely manner. Permit Holder
or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by
required special inspections.
REQUIRED INSPECTIONS APPROVED/DATE
* *See also on final Ins ection Record
FOOTINGS -per engineered details; all soil bearing
surfaces shall be inspected by geotech prior to placement
of resteel and concrete as noted on Sheet A7 of plans
Setbacks
Forms
Widened Footing
Reinforcement - #6 typical per engineering
#3 Stirrup embedment
Roughened "cold joint"
• CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 2
Building Permit #BLD02-185R-2 ,
FOUNDATION -Refer to engineering details. Chance
anchors torque, driven depth, attachment of pile caps, etc.
require special inspection as noted above.
StemwalUGrade Beam
Forms
Reinforcement - #6 and #4
#3 Stirrups
New Crawl Access Opening
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing
and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free
of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc.
once construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior
to scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project. .
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST TffiS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates •
1-800-424-5555
Page 2 of 2
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone:360-379-5086 Fax360-385.7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-185R-3 Issued: 07/21/03 Parcel Number: 989 714 210
Job Address: 610 Hudson Place Zoning: R-II Type: V-N Occupancy: RR=3
Total Occupant Load: 7 Nature of-Work: Revision #3: new detail showing section view of
foundation reinforcement at steel columns.
Owner: Mike & Shelly Reiss Contractor: Little & Little Construction - LITTLLC157C5
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
NOTE: ~ecial Inspection is required or bolting of pile caps and Chance anchors per Uni orm
Building Code Section 1701.5 and as required in the Soils Report rom Aspect Consulting. Special
Inspection Reports shall be copied to the Building Department in a timely manner. Permit Holder
or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by
required special inspections.
REQUIRED INSPECTIONS APPROVED/DATE
'~*J'ee also original lnspectton Kecord'~'~
FOOTINGS -per engineered details; all soil bearing
surfaces shall be inspected by Geotech prior to placement
of resteel and concrete as noted on Sheet A7 ofplans
Setbacks
Forms
(6) #5 vertical drilled and epoxied into footing with
Hilti HY-150 or equivalent
#3 Stirrups @ 1 foot o.c.
(2) #6 continuous @ top
#4 ties
(2) #6 continuous @ bottom
-a'
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 2
Building Permit #BLD02-185R-3 '
FOUNDATION -Refer to engineering details. Chance
anchors torque, driven depth, attachment of pile caps, etc.
require special inspection as noted above.
Detail 8 dimension changed from 6" & 6" to 8" & 4"
revised detail
(3) #5 each face
(3) #4 @ top rest @ 8" (changed from 4")
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing
and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free
of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc.
once construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prio"r to cover.
i
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by •
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior
to scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
9. Revisions require review and approval riot to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phoce:360-379-5086 Fax360-3857675
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDU2-185R-4 Issued: 7/31/03 Parcel Number: 989 714 210
Job Address: 610 Hudson Place Zoning: R-II Type: V-N Occupancy: RR=3
Total Occupant Load: 7
Nature of Work: Revision #4: revised details for deck footing, and wall construction.
Owner: Mike & Shelly Reiss Contractor: Little & Little Construction - LITTLLC157C5
GENERAL CONDITIONS APPLY: See last cage
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
NOTE: Speciallnspection is required for bolting ofpile cis and Chance anchors per Uni orm
Building Code Section 1701.5 and as required in the Soils Report from Aspect Consulting. Special
Inspection Reports shall be copied to the Building Department in a timely manner. Permit Holder
or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by
required special inspections.
REQUIRED INSPECTIONS APPROVED/DATE
**See also on final Ins ection Record **
:]
FOOTINGS -per engineered details; all soil bearing
surfaces shall be inspected by Geotech prior to placement
of resteel and concrete as noted on Sheet A7 of plans
Deck Footings - Sonatubes with stirrups ;
f
Reinforcement ~ y ~-~,'~~~,~ -:;
v- , ~ ~' /
#6 bottom bars stubbed into pier
(4) #4 vertical bars
#3 ties @ 8" o.c.
#6 top bars continuous over pier
FOUNDATION -Chance anchors torque, driven depth,
attachment of pile caps, etc. require special inspection as
noted above
See attached plan
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 2
Building Permit #BLD02-185R-d'
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
~ ,.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before ou di for utili line locates
Y g Ty
1-800-424-5555
Page 2 of 2
r
.
. /
.
d
~,,
: ~ ,~
..
~-
_r
- „_.-dam"'-`"_""`,...
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
ti __ ~_.~
Permit Number: BLD02-185R-Jr Issued: 09/08/03 Parcel Number: 989 714 210
Job Address: 610 Hudson Place Zoning: R-II Type: V-N Occupancy: R_3
Total Occupant Load: 7
Nature of Work: Revision #5: revised details for truss (a~ guest bedroom and header support
Owner: Mike & Shelly Reiss Contractor: Little & Little Construction - LITTLLC157C5
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
NOTE: See Original Permit and other revisions for other inspections.
REQUIRED INSPECTIONS
FRAMING
Revised PSL Beam/Truss Connection Detail; Sheet A-9 of
original plans
Hangers -Simpson U210 or THA213
Nailing _---
Revised Header Support; Sheet S-1 Detail K of original
plans
Bundled Studs (2) 2 x 6
Simpson A35 with tabs bent both directions, typ.
APPROVED/DATE
~~
C~~~G ,
Building Permit #BLD02-185R-5 ,
GENERAL. CONDITIONS
1. Contractors workin on this ro'ect are re
g p ~ quired to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is repaired. Public Works approval
must be received prior to scheduling the Building Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
City of Port Townsend
Building & Community Development
Waterman & Katz Building ,~„ _,~„_
181 Quincy Street ~~ ;gg,"`L
Port Townsend, WA 98368
(360) 379-3208 Fax: (360) 385-7576
CERTIFICATE OF OCCUPANCY
BLD02-185
Owner: Mike and Shelly Reiss
Address: 610 Hudson Place
Location: Port Townsend, WA 98368
Building (or portion): Single Family Residence with carport
Use(s) permitted: Dwelling Unit with accessory uses
•
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Approved: Penny Westerfield July 16, 2004