HomeMy WebLinkAboutBLD02-078Waterman & Katz Building
181 Quincy Stree4, Suiu 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD02-~7g Issued: OS-21-02 Parcel Number: 989-711-004
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
Job Address: 1415 Clav Street Zoning: R-II Type: V-N Occupancy: R-3/U-1
Total Occupant Load:2/2 Nature of Work: Detached Garage with upstairs ADU
Owner: Dennis Kelly & Elizabeth Crumley Contractor: Owner
RF.nTTTRF.T) TNCPF.f TTC1N4
APPRnVF.n/nATF
TEMP EROSION & SEDIMENT CONTROL
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
GROUNDWORK PLUMBING ~°s
Pressure Test ~~~~~~'
Pipe Joints Exposed
Pipe Bedding
MONOLITHIC SLAB FOUNDATION
~~`
~~~=`
~~hj
Setbacks /
Forms
Reinforcement
Anchor Bolts ~c~i(J~jRlr~p~
~ij~ C
ABWP Holdown Hardware
Interior Footings
Porch Piers
UFER
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
n
Permit # BI D02.178 -
'a
&LOUIRED INSPECTIONS ``~. APPRnVF.n/nATF.
LOOR FRAMING
Joists -Engineered BCI plan on-site at time of inspec ' n
Blocking
Positive Connections ~
Treated Wood to Concrete ~
Anchor Bolts w/ 2" x 2"x 3/16" washers ~
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
~
Water Hammer Arrestor at clothes and dishwasher ~
Gas Supply °~
Hose Bibs (backflow protection required)
Pipe Insulation (minimum R-3) ~ `,
~`
Pressure Reduction Valve if > 80 psi ~
~
Water Heater ~
Seismic Restraint - 2 places `_
Pressure relief valve drain to exterior, terminate
3
6" - 24" above ground
~'
MECHANICAL
LPG Heater and Water Heater -manufacturer's installation
instructions shall be on-site at time of inspection
Whole House Fan -Bathroom
Kitchen Fan
Garage Bath Fan /+
/
FRAMING
Walls
/
~
ABWP Walls for 1~` of 2-stories
Ceilings
Roof
Rafter Positive Connection
Blocking
Attic Venting - @ ridge & eave
Windows -escape
Window safety glazing
Windows Ufactor - .70 or better
NFRC window sticker must be on windows and doors
at inspection time
Air Seal
Fresh Air Intake (Wald Ports)
Fire Blocking
Bather Resistive Barrier
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
J
~ Pemtit # BLD02-078
•
REnI1IRED INSPECTIONS APPROVED/DATE
INSULATION
Floor (R-19 required)
Walls (R-19)
Ceiling f R-30)
Bales _ __
vapor Bar"mer: Paint
`~~
~-
`,
DRY WALL NAILING P
t
Walls _:
Ceiling ~ ,
Garage/House Occupancy Separation
FINAL
LPG
House Numbers - 5"
Plumbing S
~
Mechanical/Heating ,` '
~ ~ 7 r
Insulation Certificate Q
Smoke Detectors
Vapor Barrier Paint Certificate
Landing, Stairs, Handrails, Guardrails
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shalt review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page3of4
Permit # BLD02~78
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residen~ial project.
8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before ou di for utili line locates
Y g h'
1-800-424-5555
Page4of4