Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD02-060
Waterman & Katz Building 181 Quinry Street. Su-te 301 Port Townsend, WA 98368 Phone: 3603793208 Faz360383-7675 CITY OF PORT TOWNSEND :7 r CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: $I~DOZ-~6~ Issued: 04/30/02 Parcel Number: 948 330 602 Job Address: 12121st Street Zoning: R-II Type: V-N Occupancy: RR=3 Total Occupant Load: 5 Nature of Work: New single-family dwelling Owner: Wayne Chisholm Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RF(1TTTRFn TN4PF(".TTnN4 APPRnVFD/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition #2 Silt Fence as needed Drive Off Mat per attached details FOOTINGS ,~~~ Setbacks ~~~~.- Footings Forms Reinforcement Interior Footings Porch Piers LIFER FOUNDATION Stem Wall ~j ~ ~~(~~ Forms Reinforcement Anchor Bolts w/ 2" x 2" x 3/16" square washers Vents -10 required Crawl Access Beam Pockets Ca11 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Building Permit #BLD02-060 ~'' REQUIRED INSPECTIONS APPROVED/DATE FLOOR FRAMING Engineered LPI plan to be on-site @ time of inspection Girders Joists Blocking Shield under Posts Positive Connection Girder to Concrete Beam Pockets Treated Wood to Concrete Anchor Bolts & Washers ~l~l ~ 2 PLUMBING: Rough-In (D-V-T & Clean Outs) ~ w v ~ l.~S ,~~/Z~1~2 Water Supply Water Hammer Arrestor @ clothes & dishwasher Gas Supply ~olz5 ~i ~ P // ~ ©L- / / Hose Bibs (backflow protection required) Pipe Insulation - R-3 Pressure Reduction Valve if > 80 psi Water Heater Seismic Restraint - 2 places Pressure relief valve drain to exterior MECHANICAL Gas Fireplaces (2) Electric Heat Pump M ' ll I b anufacturer nsta ation Instructions to s e on-site @ time of inspection ~~~1 ~ 0' 1i Ducts & Duct Insulation -Supply/fresh air . ducts in conditioned space: R-4; heating ducts in unconditioned space: R-8 Whole House Fan @ upstairs bath Source Specific Fans Environmental Air Exhaust ducting (with backdraft damper), insulation (R-4) and terminus (located 3' from opening) Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 • • r Building Permit #BLD02-060 • REQUIRED INSPECTIONS APPROVED/DATE FRAMING Walls b l an to e on-site at Roof -Engineered truss p time of inspection / //l~ ~~ /~ C C / Attic Venting -ridge & soffrt Ceilings Posts, beams & headers Windows -egress Windows -safety glazing Windows Ufactor - .49 or better NFRC window sticker must be on Windows & doors at inspection time Air Seal Doors Ufactor - . 39 or better (wood) Truss Positive Connection Fire Blocking Weather Resistive Barrier INSULATION Fl R 19 o r ( ) o - ~ ~~ ~~~ Z- ~G~~~~ ~G~ti' Wall (R-19 ) ( Ceiling (R-30 ) Baffles Vapor Barrier: paint Crawl space - 6 mil black poly DRY WALL NAILING Walls /~ ~ O L C Ceiling Interior Braced Wall Panels FINAL Public Works Sign-Off House Number - S"numbers LPG Plumbing Mechanical Insulation Certificate V. B. Paint Certificate Smoke Detectors Final -Building a Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Permit #BLD02-060 ' '^ GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's -. registration number and a City business license. Failure to provide proof of this documentation prior work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 rior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 r Waterman & Katz Building • , 18l Quincy Street, Sulu 301 Port Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)379-6923 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number; BI..D~2-~6~R-1 Issued: 4/30/02 Parcel Number: 948 330 602 Job Address: 1212 1st Street Zoning: R-2 Type: V-N Occupancy: U-1 Nature of Work: Construct 1009 sg. ft. Garage Owner: Wavne Chisholm Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE RF.(1TTTRF.n TNCPF.(''TTfINC APPRnVF,n/nATF TEMPORARY EROSION & SEDIMENT CONTROL See General Condition No 2 FOOTING Setbacks J~Il~~Z, Footings Forms Rei cement E ~ ~ ~~ FOUNDA ON ~.. Stem Wall ~/Z~~ `' ~~~ Forms Reinforcement Anchor bolts w 2"x 2" x 3/16" washers FRAMING Walls Treated Wood to Concrete Anchor Bolts Ceiling/Roof -engineered truss plan shall be on-site at time of inspection Truss Positive Connection Blocking Weather Resistive Barrier FINAL Final -Building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 t Permit # BI,D02-060R-1 ' " GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to _ scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 ~ E ~t -- ~1 l~~(C~~ City of Port Townsend • ~s~ Building & Community Development Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 (360) 379-3208 Fax: (360) 385-7675 TEMPORARY CERTIFICATE OF OCCUPANCY March 13, 2003 through September 14, 2003 Permit Number: BLD02-~6~ Issued: 04/30/02 Parcel Number: 948 330 602 ~ f- ~ ~ v ~ y~ Job Address: 12121st Street Zoning: R-II Type: V-N Occupancy: RR=3 VfG' (~~i~v~ Total Occupant Load: 5 Nature of Work: New single-family dwelling Owner: Wavne Chisholm Contractor: Same as Owner The above-referenced building or portion complies with the applicable requirements of the Port Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used and occupied prior to completion and final inspection without substantial hazard, and is hereby granted this Temporary Certificate of Occupancy, provided substantial progress is being made toward completion and final inspection is passed by the date entered above. This certificate of occupancy shall be posted in a conspicuous place pll the premises and shall not be removed except by the building official. C.L. Flint Building Inspector Complete Remaining Items for Final ~" . ~- ~, c` _ ~: i C~ ~ 1. Complete exterior siding. 2. Deny access to exterior doors until landings are complete. 3. Install finish handrail at main entry. Handrail located 34"-38" above a line tangent to the stair nose, and to extend from top stair nosing to the bottom stair nosing and be returned to at ends. G V~~ l . • - . ,° /~~ ~ ~ ~ .C3 ~ ~ - G~ /~ rsS s r S 7~/` r-~ I~ ~Et/J'~ 7'v`` P` ~G~h 1 ~c~' / U4-^ !ii ~E'- C~ ~~ S a/YYl W t~ ~ h ~ O~ ~ ~ C ~ ~~U7"~~, "t- ~ CSC !s <t ~'1~ / !°~ C 1 ~"C7f1 ~~ /^ ~ C? r/ ~ ~r ~G '~ ~° U ~ ~~~c G ~~l /~~ i~ ~ ~ ~ r"SS ^^ ~ ~ y ~ '~ 3 a~~. c .~ _ ~ ~ ~ %~ o ~ -~3 ~.-n ~ `i ~-^ ~' ~ vt o ~ 4 ... ~ # ; ~~ ~ ` _.._..e.._ . _. :_ _.. .` .__. P 4 ~ t