CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: $I,D9g-20$ Issued: 9116199 Parcel Number: 955900078
Owner: Hamilton Heights LLC Contractor: Kozeliskv's Home Service #KOZELSM200K9
Job Address: 2666 Crest Avenue Zoning: PUD Type: VV=N Occupancy: R-31U-1
Total Occupant Load: 5/2 Nature of Work: Set Manufactured Home: construct earage & deck
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUHtED:
Electrical -Contact Labor & Industries @ 360-417-2702
u>cnrTrn~r- Tlvcn~rTrnlvc
APPROVF.D/DATE
TEMP EROSION & SDM'T CONTROL
See attached details and general condition #2
Silt Fence
Drive Off Mat
SLAB /~G
~~
Q
7
Setbacks l
i
7 /
Forms ~ /1 /I ~~ //~q n~
`~~l•~
V ~
Monolithic Slab/Fdn. (garage) ,
! C~
Reinforcement
Anchor Bolts
Alt. BWP Holdown Hardware
IJFER nA
FLOOR FRAMING (prior to skirting) ~ /f
Anchors -see attached details from set-up manual ~ Z l ~ ~ / ~ /-',/i
`
'
Steel Support Piers -Load-stamped and installed -
L
! G
per manufacturer's installation manual; clearance
of 18"min. from lowest paint ofl--beam and the
ground or footingfor min. of 7.i% of area under
home w/ 12 "min. elsewhere
Area around home graded to provide runoff away
from home
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 1 of 4
Perntit MBLD98-208
REQUIRED INSPECTIONS APPROVED/DATE
PLUMBING: see attached set-up manual
details
Water Supply -Main shut-off valve (port or /~~`"U
ball valve) installed in water supply piping prior
to connection to home, min. '/> "diameter, same as
supply pipe
Pressure Reduction Valve if> 80 psi
Hose Bibs (bckflw pro.req'd)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 p.s.i. for IS minutes
Pressure relief valve drain - to exterior of
skirting, exhaust dowmvard between 6" and 24"
above ground
Drainage Piping -sloped min, j/,'%ft.
MECHANICAL -see attached details from _ n
set-up manual ,~
~/Q
f V
~~~
Ducts & Duct Insulation /
~
r ! lll//
Dryer Exhaust -vented to outside. Extension
into crawl space requires venting through skirting
with no dips; follow dryer manufacturer's
instructions; total combined length of ducting not
to exceed 14' w/2-90° elbows
FRAMING:
Engineered truss plan to be on-site at time of
t ~/r/l /(a/>
t
inspection d t l l
Walls
Alternate Braced Wall Panels
Roof -garage
Deck -floor joists, beams, posts
VAPOR BARRIER
6 mil black poly ground cover not required
where area under home is concrete slab floor
with a minimum thickness of 3 %s inches
DRY WALL NAILING
aration
Se
anc
G
/H
O ~ y 1/,/ /a /1 ~ln
`~ `l` l `7 t~
p
arage
ccup
y
ouse
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
•
Permit #BLD98-288
•
RE UIRED INSPECTIONS APPROVED/DATE
FINAL
Public Works Sign-Off ~~2, //~/a
`
_
Electrical (L & I) Sign-Off Z
/ l
House Number
Plumbing
Mechanical
Final -Building
Deck
No holes or gaps greater then '/: "allowed in
skirting.
Crawl space ventilation per installation
manual @ 1/150 (16 req'd.); located close to
corners, on at least two opposing sides for cross
ventilation.
Crawl space access must provide access to all
areas under home; minimum 18 " x 24 "; covered
with vinyl, p. t. wood or metal.
GENERAL CONDITIONS
• 1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing,. holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shalt review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
Ca1148 hours before you dig Tor utility line locates
1-800-424-5555
Page 3 of 4
Permit kBLD98-208
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making change to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4