Loading...
HomeMy WebLinkAboutBLD98-182City of Port Townsend Building and Community Development 540 Water Street Port Townsend, WA 98368 BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD ~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 438 22ND ST Parcel No: 958201604 Project: Issued: 10/12/98 L ~{tT BLD98-00182 OWNE MODENA CAROL ANNE DANA ROBERTS 438 22ND ST -CONTRACTOR/OWNE MODENA CAROL ANNE DANA ROBERTS 438 22ND ST ona7 TnwniS FND WD 9R36R7R06 _ _ (Project began as 9504-15-and included a new roof and rehab of Floor-2.) Add 20 SF to dining area; add 100 SF unheated to utility room; replace rotting deck w/open sided covered porch (80 SF) and add new deck (220 SF). City Contact: RS Construction Type/Occ Use/Occ Load Type of work: ADD Construcfion Occupancy Type of use: SFR Type 1: SN Group t: R-1 Load 1: 3 Census Category: 434 Type 2: Group 2: Load 2: Estimated Value: $24,000.00 Type 3: Group 3: Load 3: Zoning: R-11 51 Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspect TEMP EROSION & SDM'T CON -Farms Insp-See Special Condition 1 -Reinforcement DEMOLITION -Anchor Bolts 4~QVNi2~ET Insp-See Special Conditions T- -Vents '.~ FOOTINGS ~ Crawi Access -Setbacks FLOOR FRAMING Z -Forms -Girders -Reinforcement -Joists -Interior Footing -Blocking -Porch/Deck Bay Piers -Positive Connection -LIFER -Anchor Bolts 8 Washe C~Ugy~ °OUNDATION -FDN Vents 3 em Wall PLUMBING Call 48 hours bore you dig for utility line locates 1-800-424-5555 Page 1 of 3 City of Port Townsend boll Water Street Port Townsend, WA 9868 Building and Community Development BUILDER'S PERMIT AND INSPECTFON RECORD. THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 438 22ND ST Issued: 7oH2/98 Parcel No: 958201604 Block Project: ~(~d:F~ ~LD98-0018 Inspection Date Inspector Ins Date Inspector Insp-See Special Conditions ~ -Ceiling MECHANICAL ~ FINAL fnsp-See Specia{ Conditions ~ Final-House Number FRAMING 2 ~ Final-Plumbing -Walls Final-MechanicallHeating -Roof Final-Insulation Certificate -Window U Value Final-Smoke Det. Tttrougout -Window Safety Glazing Final-LPG (Fire Dept.) -Air Seal Final -Building 5 ~~ -Fresh Air Intake (Wall Ports) 1 -Door(s) -Rafterlrruss Pos. Conn. -Weather Resistive Barrier INSULATION Insp-See Special Conditions /~ O ~ Insp-See Special Conditions -Floar(R-19) -Wall (R-19) -Wall (R-11) -Roof(R-19) -Baffles -Fill Exposed Cavities VAPOR BARRIER ~pL~ /A1 V,tJl~6E:AY~ ~jpnG>='' ),./y.yr/JQ~,- / "( Insp-See Special Conditions -Crawl Space - 6 Mil Poly DRYWALL NAILING y, 2 -Walls Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 City of Port Townsend Port ownsendtWp 98568 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 438 22ND ST Parcel No: 958201604 Project: SPECIAL CONDITIONS /RESTRICTIONS Lot: toG ~IT~ BLD9 -00182 1 . TESC: ApplicanUcontractorsha/l install temporary erosion control measures as required during construction. Measures shall include but are not limited to installation of silt fencing and graveled construction entrance: The public right-of-way shall be kept clean. Tracking of mud and debris from the site will not be allowed. Failure to comply with this condition will result in all work on the site being stopped. Areas disturbed by construction activity which are not to be covered by permanent impervious surtaces (e.g., parking, walkways, driveways, porches, etc.) Shall be landscaped or reseeded withing seven days after reaching final grade. Once construction is completed, the site must be permanently stabilized wish seeding, plantings, sodding, etc. Applicant is responsible for protection of adjacent properties. 2. DEMOLITON: All construction debris to be deposited in approved areas in accordance with local, state and federal laws. 3. PLUMBING: No plumbing shown on approved plans. 4. MECHANICAL: No mechanical work shown on approved plans. 5. INSULATION: See Wattsun for various insulation requirements. 6. INSULATION: Entire existing t'87J,~floor to be insulated with R-19 to offset additon energy deficiencies. -~,Fac CecQix~~ Z as~,e.~~ ~~ ~~ ~9~ ~~~2ti~~/~ex~ ~,~ 7. VAPOR BARRIER: None shown on approv plans but required: Kraft paper, 4 mil visqueen /~~D r~ ~ (~~,r~~ or approved vapor barrier paint. ~1 GENERAL CONDITIONS J 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Issued: 10/12/98 Page 3 of 3 f Waterman & KatzBuitding 181 Quincy Sveet. Suite 301 Part Townsend, WA 963b8 Phone: (360) 3793208 Faz: (360) 379-6923 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD98-1828-1 Issued: 8/17199 Job Address: 438 ZZnd Street Zoning: R_II Type: V=N Parcel Number: 958201604 Occupancy: RR=3 Total Occupant Load: 5 Nature of Work: Revision i# 1• Add 25 sa ft addt'l. dining room area: add skvliohts• reduce deck square footage Owner: Modena Carol AnneiRoberts, Dana Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE ~ ~i • ~l G"Q~0 0 See Also Original Permit and Plans • SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 >n~nrrro>c•n T>`ren~~~rrn)vc APPRCIVF.71/IIATF. v FOOTINGS/FOUNDATION FLOOR FRAMING/INSULATION/ DRYWALL/FINAL: See original permit FRAMING: See Attached WATTSUN & n / Original Inspection Record /~/ ~~~ "'""" Skylights - Crystalite ,43 U-factor ~~I Windows - .38/.41/.90 U-factor Doors -french; .37 U-factor NFRC sticker must be on new windows & doors at time of inspection Safety Glazing Call 48 hours before you dig for utility Tine locates 1-800-424-5555 Page I of 2 Pvmicx BLD9B-182R-I GENERAL CONDITIONS I. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works aonroval must be received urior to • ~..6ed..l:nn f6u R..il A:nn Tnno.-Finant~e final inennrfinn 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 2 of 2