HomeMy WebLinkAboutBLD98-175City Of Port T~WnSend 540 Water Street i r YY 1 1 1, Port Townsend, WA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection i Site Address: 1715 GISE ST Issued: 11/23/98 ~I I~ Parcel No: 948306806 Block: Project: PERMIT ~ gLD9800175 -CONTRALTO R/O W N E SMITH OTTO J KRISTIN F SMITH 1715 GISE ST P(1RT Tf11NAIRFyp 1AlA gR'tRRRn15 -_ OWNE SMITH OTTO J KRISTIN F SMITH 1715 GISE ST Residential: Construct 368 sq. ft. ADU at 1717 Gise Street with unheated workshop and deck above. City Contact: JZ Construction TypelOcc UselOcc Load Type of work NEW Construction Occupancy Type of use: SFR Type 1: 5N Group 1: R-3 Load 1: 2 Census Category: 328 Type 2: Group 2: Load 2: Estimated Value: $42,891.73 Type 3: Group 3: Load 3: Zoning: R-11 Type 4: Group 4: Load 4: SI Code: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector TEMP EROSION & SDM'T CON -LIFER Insp-See Special Conditions #/ FOUNDATION ~ /~- -Drive Off Mat Insp-See Special Conditions ~3 -Tire Wash -Stem Wall -Sweep Paved Surfaces -Reinforcement GROUNDWORK PLUMBING j Z, C,f(~ J -Anchor Bolts FOOTINGS s -Waterproofing Insp-See Special Conditions ~ FLOOR FRAMING -Setbacks Insp-See Special Conditions ;ff~ -Footings -Joists -Forms -Blocking -Reinforcement -Positive Connection -Porch/Deck Bay Piers -Treated Wood to Concrete Call 48 hours before you dig for util/itry~line locates ,/~ C"lk'~( ~f//~` Q, 1-800-424-5555 kjC~l l J~~~ `~2~`/ r /~ ++-'~ Page 1 of 3 /// City of Port Townsend Port ownsendtWA 98168 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address:.1715 GISE ST Issulue~d: 11!23/98 Parcel No: 948306806 PEI \tM1T # Block: Project: BLD9800175 Inspection Date Inspector Inspection Date Inspector -Anchor Bolts & Washers -Wall (R$6) PLUMBING -Ceiling (R-38) Insp-See Special Conditions ~5- VAPOR BARRIER -Rough-In (D-V-T & Cln Outs) L(_ vw ~ ~ -Paint -Water Supply ©, DRYWALL NAILING : ~ ~' ~Y , -Hose Bibs (bckflw pro. regd) -Walls ~ -Water Heater -Ceiling -Seismic Restraint FINAL MECHANICAL Final-House Number -Whole House Fan Final-Plumbing -Source Specific Fan Final-Mechanical/Heating -Environmental Air Exhaust Final-Vapor Barrier Cert. FRAMING Z L Final-Smoke Detectors -Walls Final-ADU Cert. of Occ. -Ceiling Final -Building -Roof -Windows: Egress -Window U Value -Air Seal -Fresh Air Intake (Window) -Fresh Air Intake (Wall Ports) -Door U Value -Rafter/Truss Pos. Conn. -Fire Blocking -Weather Resistive Barrier INSULATION 3 ~ -Below GD Wall (R~bj Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 City of Port Townsend Port ownund tWA 98388 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1715 GISE ST Issued: 11/23/98 Parcel No: 948306806 Lot: ~ Block: Praje~t: PERMIT # BLD9800175 SPECIAL CONDITIONS /RESTRICTIONS 1 . TESL: Applicant shall install temporary erosion and sediment control measures on-site as needed during construction to protect adjacent properties and right-of-way. Measures may include but are not limited to installation of graveled construction entrance, silt fencing (see attached details), tire wash and sweeping of paved surfaces. Exposed soils shall be temporarily stabilized through mulching, plastic covering, sodding etc. Once construction is completed, the site must be permanently stabilized with seeding and plantings, topsoiling or sodding. Applicant is responsible for protection of adjacent properties. 2. FOOTINGS: See engineering detail #3; vertical resteel embedded in the footing shall extend into panel wall system a minimum of 24". 3. FOUNDATION: Contractor shall provide Building Department with verification of compressive strength of concrete (2500 psi) at time of pour; inspection required @ 5 foot lifts max. per engineer. ~4. FLOOR FRAMING: See ledger details in structura{ calcs and detail #2 of structural details for ledger supporting floor joists. 5. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. CaII for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 C,1 ~J Waterman & Kalz Building 181 Quinq Streeq Suite 301 Port Tawosend~ WA 95366 Phone: 360J79-3208 Fa:360J79-6913 CITY OF PORT TOWNSEND • • CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD98-175R-1 Issued: S/ll/99 Parcel Number: 948306806 Job Address: ADU: 1717 Gise St. Zoning: RR=II Type: V-N Occupancy: RR=3 Total Occupant Load: 2 Nature of Work: Chance direction of ridge from N/S to E/W -refer to revised engineering and arch. stamped plans Owner: Kristin and Otto Smith Contractor: Same as Owner ~~/ ~.~/~/ GENERAL CONDITIONS APPLY: SEE BELOW ~ ~, ~ I SEPARATE PERMITS REOUIItED: Electrical -Contact Labor & Industries @ 360-417-27025~~( ~ RE UIRED INSPECTIONS APPROVED/DATE FRAMING Roof Rafters - 2 x 10 @ 24" o. c. per arch. plan revision Collar Ties - 2 x 6 @ ea. pair rafters w/ (6) 16d sinker ea. end per azch. plan revision LR2 & LRS -add 4 x 6 posts; see engineered revision for attachment details n r l / . ~~. Y~rJ~-.n~~ ~,y. GENERAL CONDITIONS 7~3~0/ ~~/ 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 2 Pmnit #BLD98-175Rd 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass £nal inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-residential project. 8. All building permits expire if no progress has been made within 'six months, or if no inspections are done by the Building Department within one year. Cal] for at least one inspection per year to keep your building permit active. 9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 2 1-800-424-5555 Page 2 of 2 i l s