HomeMy WebLinkAboutBLD98-1561;
City of Port Townsend 540 Water Street
Port Townsend, WA 98768
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
i
PO
0r/i~'i~/ ~Lli~Gc7?
D, WA 98368
Issued: 9/28198
PE ~~MIT #
Block:
BLD98-00156
WNE
CRAIG WALLIN
702 WOODLAND DR
PORT TOWNSEND, WA 98368
rrw~wi v~.rv~vr ,
New Residential: New Single Family residence~with detached garage: 1887 sq. ft. living space, 484 sq. ft. garage.
Electric heat.
City Contact: J2
Type of work NEW
Type of use: SFR
Census Category: 101
Estimated Vaiue: 5754,688.00
Zoning: R-I
~ SI Code:
Construction Type/Occ Use/Occ Load
Construction Occupancy
Type 1: SN Group 1: R3 Load 1:
Type 2: Group 2: U-1 Load 2:
Type 3: Group 3: Load 3:
Type 4: Group 4: Load 4:
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4766 MASON ST
Parcel No: 951904701
Project:
6
2
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
TEMP EROSION & SDM'T CON -Forms
Insp-See Special Conditions ~~ -Reinforcement
FOOTINGS -Anchor Bolts ,~~ v
-Setbacks -Vents ?'i'+1
i 'Y;" , ~~ ~
~`
-Footings -Crawl Access f ,; -
-Forms -Beam Pockets
-Reinforcement ~ -Alt 8WP Holdown Hdwr ~,; •~~
/•.. r ~
-Interior Footing SLAB
-Porch Bay Piers -Alt BWP Holdown Hdwr
-LIFER ~Q ~ G FLOOR FRAMING ~
FOUNDATION -Girders
Insp-See Special Conditions o1, -Joists
- em Wall ~ -Blocking
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
~' J
City of Port Townsend 540 Water Street
Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4766 MASON ST Issued: 9128/98
Parcel No: 951904701 Block:
Protect: PE MIT # gLD98-00156
Inspection Date Inspector, Inspection Date Inspector
-Shield Under Posts -Roof
-Int. Braced Wall Supports -Attic Venting
-Positive Connection -Windows: Egress
-Girder to Concrete -Window U Value
-Beam Pockets -Window Safety Glazing
-Treated Wood to Concrete -Air Seal
-Anchor Bolts & Washers -Fresh Air Intake (Window)
-FDN Vents ~~ G ~~ -Door U Value
PLUMBING j q -RafterlTruss Pos. Conn.
Insp-See Special Conditions #3 -Fire Blocking
-Rough-In (D-V-T 8 Cln Outs) -Weather Resistive Barcier
-Water Supply INSULATION
-Hose Bibs (bckflw pro. regd) -Floor (R-30)
-Pipe Insulation -Under WH (R-10)
-Water Heater -Wall (R-21) / Z
-18" A.F.F. -Ceiling (R-38)
-Seismic Restraint -Baffles ~ 2 2 ~.,
MECHANICAL VAPOR BARRIER
-Whole House Fan -Paint
-Source Specific Fan J ~ "1 -Crawl Space - 6 Mil Poly
-Environmental Air Exhaust DRYWALL NAILING
FRAMING -Walls
lnsp-See Special Conditions ~' -Ceiling
-Advanced -Interior Braced Wall Panels
-Walls -Garage/House Occ. Separation i `~~ r ~ !~
-Alternate Braced Wall Panel DRAINAGE
-Ceiling ! Insp-See Special Conditions ~{"s
Call 48 hours t(efore you dig for utility line locates
1-800-424-5555
Page 2 of 4
City of Port Townsend Po TownsendeWA 96368
Building and Community Development
BUILDER`S PERMIT AND INSPECTION RECORD
t~ THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4766 MASON ST Issued: 9/28/98
Parcel No: 951904701 PERMIT # Block:
Project BLD98-00156
Inspection Date Inspector
FINAL
Final-House Number
Final-Plumbing
Final-Mechanical/Heating ?
Final-Insulation Certificate
Final-Vapor Barrier Cert,
Final-Smoke Detectors
Final-Public Works Sign-Off ,
Final -Building ~ ~~ ('~' /~~ ',
• PECIAL CONDITIONS !RESTRICTIONS
1 . TESC: Applicant shall install erosion and sediment control measures as needed during
construction. Measures shall include but are not limited to installation of graveled construction
entrance and vegetative buffer as shown on site plan, fire wash, sweeping of paved surfaces,
etc. Rights-of-way shall be kept clean of dirt and debris. Soils exposed during construction
shall be stabilized within two days by seeding, mulching, plastic covering or other means.
Once construction is completed, the site must be permanently stabilized with seeding, sodding
or topsoiling if needed. Applicant is responsible for protection of adjacent properties:
2. FOUNDATION: East wall of breakfast nook requires alternate braced wall panel (ABWP)
unless sliding glass door is shifted to the south to provide for 4' braced wall panel (see sheets 2
and 6 of plans).
3. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
4. FRAMING: Engineered truss plan shall be on-site at time of inspection.
5. DRAINAGE: Stormwater run-off shall be directed to street ditch per Vantage Homes Master
Plan unless otherwise approved by the Department of Public Works. Re-establish Swale along
property frontage per MIP98-079.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend 540 Water Street -
Part Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4766 MASON ST Issued: 9/28/98
Parcel No: 951904701 Lot: Block:
Project: PERMIT # BLD98-00156
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress Itas been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4