HomeMy WebLinkAboutBLD98-140°, : _ City of Port Townsend 540 Water Street
Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD t3< APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: -2-1-36 IEIfd6SL-BY PL
Parcel No: 999100138
Project:
-CONTRACTOR/OWNE
PRESTIGE PROPERTIES INC.
11524 RHODY DRIVE
PORT HADLOCK, WA 98339
Issued: 8/31!98
Block:
{~~;~- ~ BLD98-00140
WNE
LARRY OLMSTEAD
124 ASH LOOP
PORT TOWNSEND, WA 98368
-PROJECT DESCRIPTIO
New Residential: manufactured home of 1512 sq ft. with 55 sq ft deck.
City Contact: J2 Construction Type/Oce UselOcc Load
Type o/work: NEW Construction Occupancy
Type of use: SFR Type 1: SN Group L R3 Load 1: 5
Census Category: 101 Type 2: Group 2: Load 2:
Estimated Value: $11,700.00
Type 3: Group 3: Load 3:
Zoning: PUD
SI Code: Type 4: Group 4: Load 4: -
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~„ PLUMBING
TEMP EROSION & SDM'T CON Insp-See Special Conditions itt~
Insp-See Special Conditions $ Z Insp-See Special Conditions~k S
FOOTINGS 3 ` s ~ Insp-See Special Conditions ~
-Setbacks Insp-See Special Conditions~C
-Footings ~~ ~~- ~ ~ ~'7 ' r~ Insp-See Special Conditionstt
-Forms -Water Supply
-Reinforcement -Hose Bibs (bckflw pro. regd)
FLOOR FRAMING )lJr~:/'. ~' -Pipe Insulation
Insp-See Special Conditions ~k?j ~ ('. " -Water Heater
-Joists -Seismic Restraint
-Positive Connection MECHANICAL
-Treated Wood to Concrete Insp-See Special Conditions ~
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
City of Port Townsend
Building and Community Development
540 Water Street
Port Townsend, WA A~;:¢8.
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2136 KINGSLEY PL
Parcel No: 999100138
Project:
Inspection Date Inspector
Insp-See Special Conditions }i ID
Insp-See Special Conditions ~
-Duct Insulation
-Whole House Fan
DRAINAGE
Insp-See Special Conditions ~ ~-Z
FINAL
insp-See Special Conditions ~t13
Insp-See Special Conditions yb ~>~
Final-House Number
Final-Plumbing
Final-Mechanical/Heating
Final-Smoke Detectors
Final-Public Works Sign-Off
Final -Electrical (L&I)
Final -Building / ~
SPECIAL CONDITIONS /RESTRICTIONS
1 . INSTALLER TAG (ATTACHED) SHALL BE POSTED ON-SITE.
2. TESC: Erosion control measures shall be installed on-site as needed during construction.
Measures may include but are not limited to installation of silt fencing, graveled construction
entrance, fire wash, sweeping of paved surfaces, etc. Sails exposed during construction shall
be covered. Rights-of-way shall be kept clean. Applicant is responsible for protection of
adjacent properties.
3. FLOOR FRAMING -Applies to decks/steps
4. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
5. PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to
home. Balbe shall be full-flow type (gate or ball valve); minimum 3/4" diameter, same as
supply pipe.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Issued: 8/31/98
Block:
1~uwu~ t~ BLD98-00140
•
Page 2 of 3
_ City of Port Townsend 544 Water Street
Port Townsend, WA 98388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2136 KINGSLEY PL Issued: 8/31/9s
Parcel No: 999100138 Blo
Project: ~e,(YY~i~' ~' BLD98-00140
SPECIAL CONDITIONS /RESTRICTIONS
6. PLUMBING: Water heater pressure relief valve drain shall extend outside of skirting, with
elbow down and terminate between 6" and 24" above ground.
7. PLUMBING: Horizontal runs in drainage system shall be sloped minimum 1/4" per foot.
8. PLUMBING: Freeze protection (insulation) required for water supply pipes outside and in crawl
space.
9. MECHANICAL: Dryer exhaust shall be vented to the outside. Extension into crawl space
requires venting through skirting with no dips; follow dryer manufacturer's instructions.
Moisture exhaust duct shall not exceed total combined vertical and horizontal length of 14 feet
with 2 90-degree elbows.
10. MECHANICAL: Whole house exhaust fan timer shalt be set to operate for 2 4-hour periods per
day unless central exhaust fan is set to run continuously.
11 . MECHANICAL: Heating crossover ducts in Super Good Cents homes shall be insulated to
minimum R-8.
12. DRAINAGE: All water drains piped to outside shall drain away from home; ground to slope
away from home for minimum 5 feet ~ 1/2" per foot.
•13. FINAL: Pier supports and anchors per manufactured home installation manual require
inspection prior to skirting. Plans spec 6000# steel piers under ridge beams; piers to be load
stamped.
14. FINAL/SKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Craw! space
ventilation per manufacturer's specs or 1/150 (17 req'd), located on at least two opposing sides
to provide for cross ventilation. Crawl space access required: ane (1) per section or as
required by manufacturer; minimum 18" x 24".
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corcections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
,.
__ _
r~
U
City of Port Townsend 640 Water Street
Port Townsend, WA 88368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
• THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
~• .. ,
Site Address: PL Issued: 12H 1/98
Parcel No: 999100138
Project:
Lot: Block:
~ERMIT # BLD98-140R1
WNE
LARRY OLMSTEAD
124 ASH LOOP
PORT TOWNSEND, WA 98368
-CONTRACTOR/OWNE
PRESTIGE PROPERTIES INC.
11524 RHODY DRIVE
PORT HADLOCK, WA 98339
-PROJECT DESCRIPTIO
Revision #t: Add attached garage to manufactured home.
Ciry Contact: JLZ Construction 7ypelOcc UselOcc Load
Type of work NEW Construction Occupancy
Type of use: SFR Type 1: SN Group 1: U-1 Load 1: 2
Census Category: 101 Type 2: Group 2: Load 2:
Estimated Value: $17,456.64
Type 3: Group 3: Load 3:
Zoning: PUD
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~~ -Walls
SLAB -Alternate Braced Wall Panel
Insp-See Special Conditions Z -Roof
-Setbacks -Rafter/Truss Pos. Conn./~,,{~,
-Forms -Weather Resistive Barrier
-Slab DRYWALL NAILING
-Monolithic Slab/Fdn -Garage/House Occ. Separation -~ (;~' /?~/
-Reinforcement FINAL
-Anchor Bolts Insp-See Special Conditions ~f
-Alt BWP Holdown Hdwr Final-House Number
-LIFER Final-Public Works Sign-Off
FRAMING Final -Building -^ ~~ -~ f j
Insp-See Special Conditions ~3 ~
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page t of 2
City of Port Townsend Port otwnsend`WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST i3E ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2136 KINGSLEY PL Issued: 12/11/98
Parcel No: 999100138 Lot: Block:
Project: PE~M~T ~ BLD98-140R1
SPECIAL CONDITIONS /RESTRICTIONS
1 . ALTERATION PERMIT FROM L & I FOR GARAGE ADDITION TO BE ON-SITE AT TIME OF
INSPECTION (HOME MAY BE GARAGE-READY; APPLICANT RESPONSIBLE FOR
VERIFYING COMPLIANCE}.
2. SLAB: Holdowns for alternate braced wall panels (ABWP) require inspection prior to cover.
3. FRAMING: Engineered truss plan shall be on-site and available to the Inspector at time of
inspection.
4. FINAL: Refer to Temporary Certificate of Occupancy (TCO) issued 10/10/98 for complete list
of conditions for final.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2