HomeMy WebLinkAboutBLD98-129~.
C ~ ty O f P O rt .~. ~1N t1 S @ f1 C~ d40 Water Street
i T r 1111 ~r Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 303 33RD ST
Parcel No: 991100009
Project:
-CONTRACTOR/OWNE
FRED KIMBALL
151 FREDERICK STREET
PORT TOWNSEND, WA 98368
Issued: 9!8/98
P'~~RMIT #BLD9s-oo~2s
WNE
DON STROMBERG
6618 PIONEER HWY
STANWOOD, WA 98292
New Residential: Two-story 2933 sq. ft. single-family residence with attached 425 sq. ft. garage. Electric Heat.
City Contact: JZ Construction TypelOcc Use/Occ Load
Type of work: NEW Construction Occupancy
Type of use: SFR Type 1: SN Group t: R-3 Load 1: 9
Census Category: Type 2: Group 2: U-1 Load 2: 2
Estimated Value: $225,000.00
Type 3:
Group 3: Load 3:
Zoning: R-It
Type 4: Group 4: Load 4:
SI Code:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions 1 -LIFER ; ~~ ?~;,~,;~
Insp-See Special Conditions ~
FOUNDATION ~ Z ~~ ~ .r t ,/
! D ~;' td'
~
TEMP EROSION & SDM'T CON -Stem Wall
Insp-See Special Conditions ~ -Forms ~+~Ar r_~~ ;Lj~T tl ~ ~ ~
GROUNDWORK PLUMBING ~ ~~ r._? l r ~' f -Reinforcement
FOOTINGS ~~, j (t C~ r;~ ; -Anchor Bolts
Insp-See Special Conditions ~K L, -Alt BWP Holdown Hdwr ~q ~, ;~ 3~ ~
-Setbacks -Waterproofing
-Footings _.~. l~ ~ SLAB
hi~y:, ~ ~ /
~
-Farms -Interior Footing
-Reinforcement -Insulation .'~2~~8 , -- ,; /Q ,n
-Interior Footing ~'
~ ~ `% ;~~ i
~ FLOOR FRAMING ~ ~ /~~ T =~
orch Bay Piers Insp-See Special Conditions ~ ~
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page i of 4
.:} A
City of Port Townsend 540 Water Street
Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD _
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME •
Call 385-2294 For Inspection
Site Address: 303 33RD ST Issued: 9/s/9s
Parcel No: 991100009 PE~tMIT # Biock:
Project: BLD98-0029
Inspection Date Inspector Inspection Date Inspecto
-Girders -Blk'g for GWB IBW Panels
-Joists ' -Ceiling
-Blocking -Roof
-Bridging ! -Attic Venting
-Int. Braced Wall Supports -Windows: Egress
-Positive Connection -Window U Value
-Treated Wood to Concrete -Window Safety Glazing
-Anchor Botts & Washers -Air Seal 2
PLUMBING ~ ~ ~ -Fresh Air Intake (Wall Ports)
Insp-See Special Conditions )} ~ -Door U Value
-Rough-In (D-V-T & Cin Outs) -Rafter/Tivss Pas. Conn.
-Water Supply -Fire Blocking
-Gas Supply -Weather Resistive Barrier
-Hose Bibs (bckflw pro. regd) INSULATION
-Pipe Insulation -Slab (R10) 222
-Water Heater -Below GD Wall (R-19)
-Seismic Restraint -Under WH (R-10)
MECHANICAL -Wall (R-19) 2
-LPG Heater -Ceiling (R-38)
-Whole House Fan -Baffles
-Source Specific Fan VAPOR BARRIER
-Environmental Air Exhaust 7 ~ -Paint
FRAMING DRYWALL NAILING
Insp-See Special Conditions ~ ~- -Walls
insp-See Special Conditions ~ -Ceiling
-Walls -Interior Braced Wall Panels
-Alternate Braced Wall Panel -Garage/House Occ. Separation
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 0! 4
City of Port Townsend 540 Water Street
Port Townsend, WA 98568
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
U
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 303 33RD ST
Parcel No: 991100009
Project:
Inspection Date Inspector
-Enclosed Space Under Stairs ~ ~~ '
<. `
DRAINAGE
Insp-See Special Conditions
-Per Master Plan
FINAL
Final-House Number
Final-Plumbing
Fin a l-Mechanical/Heating
Final-Insulation Certificate
Final-Vapor Barrier Cert.
al-Smoke Detectors
renal-Public Works Sign-Off
Final-LPG (Fire Dept.)
Final -Building
Issued: 918198
Lot: Block:
PERMIT ~iLD9s-00129
-~~,v. ~o~ a Dv s~i~/99 ~
~->L~i~~ 9~~~9~
SPECIAL CONDITIONS /RESTRICTIONS
1 . Construction areas shall be watered to suppress dust; chemical dust suppressants shall not be
used.
2. Outdoor construction activities shall be limited to lam - 6pm Monday -Friday, and prohibited
on weekends.
3. TESC -Erosion and sediment control measures to be installed on-site as needed during
construction.
4. FOOTING -Check for 5' setback on East side.
5. FLOOR FRAMING -Engineered BCI floor framing plan on site at time of inspection.
6. PLUMBING - If water pressure exceeds 80 psi, pressure reducing valve required.
7. FRAMING -Contractor to verify compliance with 30' height limit.
8. FRAMING -Engineered roof truss plan on site at time of inspection.
9. DRAINAGE -per Master Plan -owner/contractor to assure that stonnwater is directed to
approved Rosewind Storrnwater system.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend P TownsendtWA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 303 33RD ST Issued: 9!sl9s
Parcel No: 991100009 Lot: Block:
Project: BLD98-00129
GENERAL CONDITIONS PERMi t
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corcections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
Walertnan & Katz Bwlding
18I Qtmry Street, Suite 30I
Port 7oumsrnd ~'A 98368
Phone: (360) 379-3208 Fax: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD9g-130R-2 Issued: 07/06/01 Parcel Number: 965702904
Job Address: 724 Pierce Street Zoning: RR=II Type: VV=N Total Occupant Load: N/C
Occupancy: RR=3 Nature of Work: Revision #2: Revise roof framing plan
Owner: Chris Kluck and Sara Katz Contractor: Same as Owner
**All elements of engineering require inspection prior to cover**
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
See original permit 98-00130 for other inspections.
FRAMING:
Roof
•
t l ` ~J
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit N 13I.D96-130R~
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construMion entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-tour hours notice is required. Public Works aoaroval must be received prior to
scheduline the Buildine Deaartment's final inspection.
Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page2of2
Waterman & Katz Building
181 Quincy Svee4 Suice 307
Pott'1'ownsend, WA 98368
Phone: (360)379-3208 Fax: (360)3796923
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BI,D9g-IZ9I2-3 Issued: 711/99 Parcel Number: 991100009
Job Address: 303 33`" Street/ADU: 305 33`d Street Zoning : Rosewind PUD Type: VV=N
Occupancy: RR=3 Total Occupant Load: 3 Nature of Work: Certificate of Occupancy for an ADU
Owner: Pat and Don StromberQ Contractor: Fred Kimball
r~cl17 T7D LET T7~TCUri f"i`r l1NC
•
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Per Original Permit
APPRnVF.TImATF.
Occupancy Separation
1 hour separation (2- layers of 5/8" Type X GWB)
Utilities
Access to electrical shut-off
Access to water shut-off
Access to LPG shut-off
Access to Water Heater
Exiting
Stairs
Landings _ -
Handrails
Guardrails -
Escape Window
Plumbing/Cooking
Lavatory
Water Closet
Bath/Shower
Dishwashing Sink
Refrigerator
Cooking Appliance
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Pemtit p aLD99-129Rd
REQUIRED INSPECTIONS APPRnVF.II/nATF
Framing
Minimum Ceiling Height - 7 feet
Closet
Mechanical
Fire/Smoke Damper @ common wall/ceiling
duct penetrations
Final
LPG (Fire Dept.) ~~~~~~ ~/) ,t
~/
0
House Number ~
Smoke Detectors
Final -Building
ADU Cert. of Occupancy
GENERAL CONDITIONS
•
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
8cheduline the Buildin¢ Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Pmnit X BLD99-129Rd
8. All building permits expire if no progress has been made within six months, or if no inspections are done
• by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
C~
C~
J
i